Preferred Language
Articles
/
mRdsX5MBVTCNdQwCe9IB
Role of Gamma Camera Components in Radiological Diagnosis

The gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photomultiplier tube contains a photo emissive cathode (photocathode), focusing electrodes, an electron multiplier, and an electron collector (anode). Conclusion: In the medical imaging area, everyone works to improve the resolution, sensitivity, and size of their devices so that patients can be treated better and diagnoses can be made more accurately. Also, the results of this study suggest that HGC could be a potential way to give better support during surgery.

Publication Date
Thu Mar 09 2017
Journal Name
Sensors
A Multimodality Hybrid Gamma-Optical Camera for Intraoperative Imaging

The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detec

... Show More
Scopus (24)
Crossref (25)
Scopus Clarivate Crossref
View Publication
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
A hand-held hybrid gamma-near-infrared fluorescence imaging camera

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm

... Show More
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
Diagnostic Accuracy of Different Radiological Investigations in the Diagnosis of Perforated Duodenal Ulcer

Background; Perforated duodenal ulcer (PDU) is a common surgical emergency that is associated with high mortality and morbidity. Early diagnosis and prompt surgical treatment is required to prevent grave complications.
Objective; The study was designed to evaluate the diagnostic accuracy of different radiological investigations in the diagnosis of perforated duodenal ulcer.
Methods; A prospective study of 185 pts with PDU at al kindy teaching hospital, Baghdad, Iraq from June 2008- august 2010. patients were examined clinically and investigated by blood test, chest x ray, plain X ray of the abdomen. Ultrasonography (U/S) and CT scanning done for those patients with negative X- ray finding. Resuscitation by intravenous fluid and ant

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
2016 Ieee Nuclear Science Symposium, Medical Imaging Conference And Room-temperature Semiconductor Detector Workshop (nss/mic/rtsd)
Comparison of columnar and pixelated scintillators for small field of view hybrid gamma camera imaging

Scopus (1)
Crossref (1)
Scopus Crossref
View Publication
Publication Date
Thu Sep 01 2016
Journal Name
Physica Medica
Quantitative analysis of sentinel lymph node detection using a novel small field of view hybrid gamma camera (HGC)

Introduction The Hybrid Gamma Camera (HGC) is being developed to enhance the localisation of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. Purpose To assess the capability of the HGC, a lymph-node-contrast (LNC) phantom was constructed for an evaluative study simulating medical scenarios of varying radioactivity concentration and SLN size. Materials and methods The phantom was constructed using two methyl methacrylate PMMA plates (8 mm thick). The SLNs were simulated by drilling circular wells of diameters ranging between 10 mm and 2.5 mm (16 wells in total) in one plate. These simulated SLNs were placed underneath scattering material with thicknesses ranging between 5 mm

... Show More
Crossref (1)
Crossref
View Publication
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
Capability of a novel small field of view hybrid gamma camera (HGC) for sentinel lymph node and small organ imaging

Objectives: Small field of view gamma detection and imaging technologies for monitoring in vivo tracer uptake are rapidly expanding and being introduced for bed-side imaging and image guided surgical procedures. The Hybrid Gamma Camera (HGC) has been developed to enhance the localization of targeted radiopharmaceuticals during surgical procedures; for example in sentinel lymph node (SLN) biopsies and for bed-side imaging in procedures such as lacrimal drainage imaging and thyroid scanning. In this study, a prototype anthropomorphic head and neck phantom has been designed, constructed, and evaluated using representative modelled medical scenarios to study the capability of the HGC to detect SLNs and image small organs. Methods: An anthropom

... Show More
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The role of spiral Computerized Tomography in diagnosis of stroke

Objective: The aim of this study is to determine the role of spiral Computerized Tomography in the diagnosis and
detection the types of stroke.
Methodology: One hundred sixty two patients (162) (99 males and 63 females) their ages ranging from (13 – 80)
year, all of them are suffering from stroke. They were collected randomly from spiral Computerized Tomography
unit in Baquba Teaching hospital during the period from November / 2010 to December / 2011 .All the patients
were examined clinically and then done spiral Computerized Tomography examination.
Results : The results of this study showed that the stroke effected different age groups and both sex but males is
more affected than the females .The results of spiral

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 03 2011
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Evaluate The role of widal test in diagnosis of typhoid fever

Background: Widal test and blood culture together must be depended to diagnosis of typhoid fever.

Crossref
View Publication Preview PDF
Publication Date
Mon Oct 01 2007
Journal Name
Journal Of The Faculty Of Medicine Baghdad
the role of interferon - gamma( IFN-Y) In infectious mononucleosis like syndrome

Background: infection monomcleosis is caused by the ubiquitous Epstein-Barr virus.

Crossref
View Publication Preview PDF
Publication Date
Sun Nov 08 2020
Journal Name
Journal Of The Faculty Of Medicine Baghdad
the The Role of Ultrasound in the Diagnosis of Malignant Thyroid Nodules

Background: Thyroid nodules are very common in clinical practice. Although most of thyroid nodules are benign, it is crucial to checkout which nodules are more likely to be malignant. Ultrasound is a major diagnostic tool for screening and evaluating thyroid diseases because it is safe, non-invasive, non-radioactive and effective.
Objective: The aim is to identify the role of ultrasound in assessing thyroid nodules and to review various ultrasound criteria predicting malignancy.
Patients and methods: A case series study conducted during the period from January 2015 to February 2016 at the First Surgical Unit, Department of Surgery, Baghdad Teaching Hospital by a team of surgeons. One hundred eighty Patients who underwent surgical i

... Show More
Crossref
View Publication Preview PDF