The aim of this paper is to determine the flexural moment capacity of Reactive Powder Concrete (RPC) two-way slabs based on three models proposed by previous studies (Model 1, Model 2, and Model 3). The results obtained from these models were compared with those obtained from experimental work to check the accuracy and the applicability of the adopted theoretical models. The experimental program included the testing of three simply supported RPC two-way slabs (1000x1000x70) mm each. The tested specimens had identical properties except their steel fibres volume ratios (0.5 %, 1 %, and 1.5 %). The comparison with the experimental data showed that (Model 3) is the most suitable one among the three models. Model 1 was found to underestimate the failure load, and Model 2 was found to overestimate it. The maximum differences between the theoretical and experimental failure loads obtained from Model 1, Model 2, and Model 3 were 55.2% 87.2%, and 3.4%, respectively.
The search included a comparison between two etchands for etch CR-39 nuclear track detector, by the calculation of bulk etch rate (Vb) which is one of the track etching parameters, by two measuring methods (thichness and change mass). The first type, is the solution prepared from solving NaOH in Ethanol (NaOH/Ethanol) by varied normalities under temperature(55˚C)and etching time (30 min) then comparated with the second type the solution prepared from solving NaOH in water (NaOH/Water) by varied normalities with (70˚C) and etching time (60 min) . All detectors were irradiated with (5.48 Mev) α-Particles from an 241Am source in during (10 min). The results that Vb would increase with the increase of
... Show MoreBackground: The prevention of the enamel demineralization at the periphery of the brackets is a significant challenge to orthodontic professionals. The aim of this clinical study was to compare the Streptococcus mutants count in the plaque surrounding two orthodontic adhesive types, Fuji Ortho LC and Enlight (Ormco). Materials and methods: A total of 13 patients (7 male and 6 female) needing fixed orthodontic appliance therapy were participated. A split mouth technique was followed with appliances bonded by two orthodontic adhesive types, Fuji Ortho LC and Enlight (Ormco). Saliva was collected before placement of appliances (T0) and again at three weeks (T1) and six weeks (T2) after placement of appliances. Plaque was collected from areas a
... Show MoreThis paper presents a vibration suppression control design of cantilever beam using two piezoelectric patches. One patch was used as an actuator element, while the other was used as a sensor. The controller design was designed via the balance realization reduction method to elect the reduced order model that is most controllable and observable. the sliding mode observer was designed to estimate six states from the reduced order model but three states are only used in the control law. Estimating a number of states larger than that used is in order to increase the estimation accuracy. Moreover, the state estimation error is proved bounded. An optimal LQR controller is designed then using the estimated states with the slid
... Show MoreThe paper presents research results of the vibration transmitted from the steering wheel of the tractor with a 2-wheel drive to the driver’s hands. The vibration measurements were carried out on the tractor randomly chosen from the collage of agriculture / university of Baghdad. Before testing the tractor was examined and adjusted following the producer’s recommendations. The vibration levels were measured during the operation tillage at idling and at full load .The field was 31.7 m above level sea. Soil was treated at soil constant moisture (17-20 %) with depth of plowing (17 cm). During operation the weather temperature was measured (15 C) and humidity was ( 27 % ) The vibration level on the steering wheel was measured and analyzed .T
... Show MoreTwo Prototypes of Transversely Excited at atmospheric pressure (TEA) Nitrogen laser systems (One Stage Blumlein Circuit and Two Stage Blumlein Circuit) were fabricated and operated. High voltage power supply with variable operating voltage (0-20 kv) and operating current (1-3A) was built and tested successfully. The gas flow rate of 15 L/ min and 10 L/ min for OSBC and TSBC was used. The performance of the fabricated systems was studied extensively reaching to the optimum operating conditions. The obtained laser output energy for the first system has linear relationship with the applied voltage. The maximum output energy was about (1.14 mJ) with (10.40) ns pulse duration and the half-wave divergence angle was about (0.1455 m rad). In the
... Show MoreIn this paper, Bayes estimators of Poisson distribution have been derived by using two loss functions: the squared error loss function and the proposed exponential loss function in this study, based on different priors classified as the two different informative prior distributions represented by erlang and inverse levy prior distributions and non-informative prior for the shape parameter of Poisson distribution. The maximum likelihood estimator (MLE) of the Poisson distribution has also been derived. A simulation study has been fulfilled to compare the accuracy of the Bayes estimates with the corresponding maximum likelihood estimate (MLE) of the Poisson distribution based on the root mean squared error (RMSE) for different cases of the
... Show MoreThe paper presents research results of the vibration transmitted from the steering wheel of the
tractor with a 2-wheel drive to the driver’s hands. The vibration measurements were carried out on the
tractor randomly chosen from the collage of agriculture / university of Baghdad. Before testing the
tractor was examined and adjusted following the producer’s recommendations. The vibration levels
were measured during the operation tillage at idling and at full load .The field was 3١٫٧ m above level
sea. Soil was treated at soil constant moisture (1٧-20 %) with depth of plowing (١٧ cm). During
operation the weather temperature was measured (15 C) and humidity was ( 27 % ) The vibration level
on the steering whee
Background: Cardiovascular disease (CVD) is an important complication of type 2 diabetes mellitus (T2DM). Oxidative stress plays a major role in the development of CVD. Saliva has a diagnostic properties aiding in the detection of systemic diseases. This study aimed to assess the association between salivary oxidative stress markers and the risk of vascular disease (VD) in T2DM patients. Materials and Methods: One hundred T2DM patients and fifty apparently healthy males were enrolled in this study. Saliva sample was collected for assessment of oxidative stress markers including: lipid peroxidation plasma thiobarbituric acid-reactive substances (TBARS), uric acid (UA) and total antioxidant capacity (TAC) levels. Arterial stiffness index (ASI
... Show More