Preferred Language
Articles
/
7xb8YYcBVTCNdQwCO0jQ
Bioactivity of Gutta flow II versus Modified Gutta Percha based Silicon Endodontic Sealers by Nanobioactive Fillers
...Show More Authors

The success of endodontic therapy is relied on radicular system cleaning, shaping, elimination of micro-organisms, and three dimensional filling of the radicular complex.This study was conducted to develop and assess new root canal sealer incorporating nano-sized bioactive glass into Gutta Flow II. The following concentration was used depend on a pilot study included adding (3%) of 45S5 bioactive glass into the Gutta Flow II. These materials were tested through assessment bioactivity. bioactivity test was undertaken after immersion of the tested samples into PBS for three days, seven days, fourteen days, and twenty eight days using FTIR too. study was found that it’s peaks was appear at level 800-1000 cm-1. The results showed that GFII group revealed no peak at the 910 cm-1, while, while BG3% revealed 179.85 pixel height, in conclusion the newly developed sealers exhibited apparent apatite and apatite precursor forming ability significantly with BG 3% while GuttaFlow II sealer showed no apatite layer forming ability.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of preheating on micro leakage of Class II composites Restoration (A comparative in vitro study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt.  in Class II cavity preparation .

Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used    group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of  composite:

... Show More
View Publication
Crossref
Publication Date
Wed Sep 20 2017
Journal Name
Mechanical Sciences
Comparative experimental investigation and gap flow simulation in electrical discharge drilling using new electrode geometry
...Show More Authors

Abstract. This study presents experimental and numerical investigation on the effectiveness of electrode geometry on flushing and debris removal in Electrical Discharge Drilling (EDD) process. A new electrode geometry, namely side-cut electrode, was designed and manufactured based on circular electrode geometry. Several drilling operations were performed on stainless steel 304 using rotary tubular electrodes with circular and side-cut geometries. Drilling performance was characterized by Material Removal Rate (MRR), Electrode Wear Rate (EWR), and Tool Wear Ratio (TWR). Dimensional features and surface quality of drilled holes were evaluated based on Overcut (OC), Hole Depth (HD), and Surface Roughness (SR). Three-dimensional

... Show More
View Publication
Scopus (5)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Aug 25 2025
Journal Name
Iraqi Journal Of Science
Magnetohydrodynyamic Flow for a Viscoclastic Fluid with the Generalized Oldroyd-B Model with Fractional Derivative
...Show More Authors

This paper deals with the Magnetohydrodynyamic (Mill)) flow for a viscoclastic fluid of the generalized Oldroyd-B model. The fractional calculus approach is used to establish the constitutive relationship of the non-Newtonian fluid model. Exact analytic solutions for the velocity and shear stress fields in terms of the Fox H-function are obtained by using discrete Laplace transform. The effect of different parameter that controlled the motion and shear stress equations are studied through plotting using the MATHEMATICA-8 software.

View Publication Preview PDF
Publication Date
Tue May 01 2012
Journal Name
Journal Of Engineering
Study on wind loads coefficients and flow field characteristics around the parabolic trough with stiffeners
...Show More Authors

wind load coefficient

Publication Date
Sat Mar 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Potential and Current Distribution in Flow Through Porous Electrochemical Reactor Working under Limiting Current Conditions
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Particle-Hole State Density Calculations with Non-Equidistant Spacing Model: II. Pairing and Exact Treatment
...Show More Authors

In an earlier paper, the basic analytical formula for particle-hole nuclear state densities was derived for non-Equidistant Spacing Model (non-ESM) approach. In this paper, an extension of the former equation was made to include pairing. Also a suggestion was made to derive the exact formula for the particle-hole state densities that depends exactly on Fermi energy and nuclear binding energies. The results indicated that the effects of pairing reduce the state density values, with similar dependence in the ESM system but with less strength. The results of the suggested exact formula indicated some modification from earlier non-ESM approximate treatment, on the cost of more calculation time

View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Archives Of Plastic Surgery
Surgical outcomes of 14 consecutive bilateral cleft lip patients treated with a modified version of the Millard and Manchester methods
...Show More Authors

Background Bilateral cleft lip deformity is much more difficult to correct than unilateral cleft lip deformity. The complexity of the deformity and the sensitive relationships between the arrangement of the muscles and the characteristics of the external lip necessitate a comprehensive preoperative plan for management. The purpose of this study was to evaluate the repair of bilateral cleft lip using the Byrd modification of the traditional Millard and Manchester methods. A key component of this repair technique is focused on reconstruction of the central tubercle.

Methods Fourteen patients with mean age of 5.7 months presented with bilateral cleft lip deformity and were operated on using a mod

... Show More
View Publication
Scopus (3)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of SO2 over Modified Activated Carbon in Fixed Bed Reactor: I, Effect of Metal Oxide Loadings and Acid Treatment
...Show More Authors

 

The removal of SO2 from simulated gas stream (SO2 + air) in a fixed bed reactor using Modified Activated Carbon (MAC) catalysts was investigated. All the experiments were conducted at atmospheric pressure, initial SO2 concentration of 2500 ppm and bed temperature of 90oC. MAC was prepared by loading a series of nickel and copper oxides 1, 3, 5, 7, and 10 w

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Study affects Pulse Parameters versus cavity length for both Dispersion Regimes in FM mode locked.: Bushra.R.Mhdi|Gaillan H.Abdullah|Mohand M.Azzawi|Nahla.A.Hessin|Basher.R.Mhdi
...Show More Authors

To demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving th

... Show More
View Publication
Crossref
Publication Date
Mon Sep 23 2024
Journal Name
European Journal Of Orthodontics
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized c

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref