Objective: To evaluate the functional outcomes after extended curettage and reconstruction using a combination of bone graft and bone cement (sandwich). Methodology: In this prospective case series 16 skeletally mature patients with primary giant cell tumor around the knee were included. Patients with previous surgically treated, malignant transformation, degenerative knee changes and those presenting with pathological fracture were excluded. The tumor was excised with bone graft filling space beneath the articular cartilage and a block of gel foam was placed over the cortical surface of picked bone graft. Remaining cavity was filled with polymethylmethacrylate cement (sandwich) with or without internal fixation. The func tional evaluation was done us ing Musculoskeletal Tumor Society (MSTS) Score six months postoperatively and after one year. Schatzker and Lambert Score was used in the last visit to assess the functional outcome Results: The mean MSTS Score was 27.13±3.030 (range, 20-30) and the mean functional arc of motion around the knee was 123.13±12.230 degrees (range, 90–135). According to Schatzker and Lambert Score 75% had excellent results, 12.5% had good results and 12.5% had fair results. Two patients (12.5%) had a recurrence of the tumor, and one (6.25%) developed postoperative fracture in the distal femur. Conclusion: Sandwich reconstruction for giant cell tumor is a good option for definite management and there is improvement in the quality of the patient's life. (Rawal Med J 202;45:637-640).
European Chemical Bulletin (ISSN 2063-5346) is a peer-reviewed journal that publishes original research papers, short communications, and review articles in all areas of chemistry. European Chemical Bulletin has eight sections, namely
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.
Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in Eye Specialty Private Hospital, Baghdad, Iraq.
Type of the Study: a prospective non randomize intervention study.
Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter
... Show MoreBackground: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat
... Show MoreThe gamma dose rates and specific activity of 137Cs, 60Co and 40K in
samples of soil taken from places near the landfill radiation at Al-
Tuwaitha site were measured using a portable NaI(Tl) detector. The
results of gamma dose rates in samples were ranged from 52.6
nGy.h-1 to 131nGy.h-1. Then the specific activity of 137Cs, 60Co and
40K in soil were determined using high pure germanium (HPGe)
detector. The specific activities were varied from 1.9 to 115500 Bq.
kg-1 for 137Cs, from 6.37 to 616.5 Bq. kg-1 for 60Co, and from 3 to
839.5 Bq. kg-1 for 40K. The corresponding health risk for the annual
effective dose equivalent varied from 1.85×10-14 to 15.7mSv/y. The
results were compared with various internationa
The flexible joint robot manipulators provide various benefits, but also present many control challenges such as nonlinearities, strong coupling, vibration, etc. This paper proposes optimal second order integral sliding mode control (OSOISMC) for a single link flexible joint manipulator to achieve robust and smooth performance. Firstly, the integral sliding mode control is designed, which consists of a linear quadratic regulator (LQR) as a nominal control, and switching control. This control guarantees the system robustness for the entire process. Then, a nonsingularterminal sliding surface is added to give a second order integral sliding mode control (SOISMC), which reduces chartering effect and gives the finite time convergence as well. S
... Show MoreThis article presents a new cascaded extended state observer (CESO)-based sliding-mode control (SMC) for an underactuated flexible joint robot (FJR). The control of the FJR has many challenges, including coupling, underactuation, nonlinearity, uncertainties and external disturbances, and the noise amplification especially in the high-order systems. The proposed control integrates the CESO and SMC, in which the CESO estimates the states and disturbances, and the SMC provides the system robustness to the uncertainty and disturbance estimation errors. First, a dynamic model of the FJR is derived and converted from an underactuated form to a canonical form via the Olfati transformation and a flatness approach, which reduces the complexity of th
... Show MoreIntroduction: Different surgical techniques used for closure of various oral defects. While each one of these techniques has its limitation; the buccal pad of fat used in last quarter of last century as pedicle or free graft in reconstruction of small to medium, congenital and acquired defects showed good potentials for success. The present study used the BPF as pedicled flap to reconstruct intra oral defects. The study aimed to evaluate of the success of buccal pad of fat pedicled flap in the reconstruction of intra oral defects. Outlining its indications, limitations and complications. Materials and Methods: The study included 19 patients (17 males and 2 females) with age range between (1- 70 years), all patients were treated with pedic
... Show MoreBackground: Osteoarthritis is a complicated, chronic disorder of cartilage and bone, associated with homeostasis of bio-elements. The current study aims to assess the role of serum progranulin levels among Iraqi patients with knee osteoarthritis. Patients and Methods: The study encompassed 50 patients aged 52.50 ± 3.12 years (25 males and 25 females), admitted to the at the Baghdad Medical City through the period from November 2021 to March 2022. All individuals were identified by physicians in a Rheumatology and Rehabilitation Outpatient Clinic and the clinical data was collected along with the assess¬ment of biochemical parameters. Fasting serum glucose, lipid profile, calcium, magnesium, alkaline phosphatase, vitamin D3, and p
... Show MoreA new way to Systems concentrates have been clarified and that allows a concentration high and analysis to automatically wavelengths of the spectrum of this system analyst of the spectrum and the center is built on Holucram Nafez gives less absorbency with efficient diffraction high when the wavelength (900 nm), which will be useful for Khallaya solar