Objective: To evaluate the functional outcomes after extended curettage and reconstruction using a combination of bone graft and bone cement (sandwich). Methodology: In this prospective case series 16 skeletally mature patients with primary giant cell tumor around the knee were included. Patients with previous surgically treated, malignant transformation, degenerative knee changes and those presenting with pathological fracture were excluded. The tumor was excised with bone graft filling space beneath the articular cartilage and a block of gel foam was placed over the cortical surface of picked bone graft. Remaining cavity was filled with polymethylmethacrylate cement (sandwich) with or without internal fixation. The func tional evaluation was done us ing Musculoskeletal Tumor Society (MSTS) Score six months postoperatively and after one year. Schatzker and Lambert Score was used in the last visit to assess the functional outcome Results: The mean MSTS Score was 27.13±3.030 (range, 20-30) and the mean functional arc of motion around the knee was 123.13±12.230 degrees (range, 90–135). According to Schatzker and Lambert Score 75% had excellent results, 12.5% had good results and 12.5% had fair results. Two patients (12.5%) had a recurrence of the tumor, and one (6.25%) developed postoperative fracture in the distal femur. Conclusion: Sandwich reconstruction for giant cell tumor is a good option for definite management and there is improvement in the quality of the patient's life. (Rawal Med J 202;45:637-640).
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.
Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in Eye Specialty Private Hospital, Baghdad, Iraq.
Type of the Study: a prospective non randomize intervention study.
Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter
... Show MoreBackground: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat
... Show MoreAs a result of the entry of multinationals companies in Iraq for investing in the joint projects through conducting agreements and contracts for work on important and strategic projects to get the necessary funds and various experiences which characterize the foreign participant sides that Iraq currently needs them and because of the non-applying the accounting processing stipulated in the unified accounting system in addition to the absence of a local accounting bases as well as the default of the participant contracts on indicating the accounting methods about those projects which are considered one of the bases that enables auditors in the public sector to depend on it, thus the research paper deals with studying an
... Show MoreThe flexible joint robot manipulators provide various benefits, but also present many control challenges such as nonlinearities, strong coupling, vibration, etc. This paper proposes optimal second order integral sliding mode control (OSOISMC) for a single link flexible joint manipulator to achieve robust and smooth performance. Firstly, the integral sliding mode control is designed, which consists of a linear quadratic regulator (LQR) as a nominal control, and switching control. This control guarantees the system robustness for the entire process. Then, a nonsingularterminal sliding surface is added to give a second order integral sliding mode control (SOISMC), which reduces chartering effect and gives the finite time convergence as well. S
... Show MoreThis article presents a new cascaded extended state observer (CESO)-based sliding-mode control (SMC) for an underactuated flexible joint robot (FJR). The control of the FJR has many challenges, including coupling, underactuation, nonlinearity, uncertainties and external disturbances, and the noise amplification especially in the high-order systems. The proposed control integrates the CESO and SMC, in which the CESO estimates the states and disturbances, and the SMC provides the system robustness to the uncertainty and disturbance estimation errors. First, a dynamic model of the FJR is derived and converted from an underactuated form to a canonical form via the Olfati transformation and a flatness approach, which reduces the complexity of th
... Show MoreComputational study of three-dimensional laminar and turbulent flows around electronic chip (heat source) located on a printed circuit board are presented. Computational field involves the solution of elliptic partial differential equations for conservation of mass, momentum, energy, turbulent energy, and its dissipation rate in finite volume form. The k-ε turbulent model was used with the wall function concept near the walls to treat of turbulence effects. The SIMPLE algorithm was selected in this work. The chip is cooled by an external flow of air. The goals of this investigation are to investigate the heat transfer phenomena of electronic chip located in enclosure and how we arrive to optimum level for cooling of this chip. These par
... Show MoreBackground Commonly heard statements such as “Christmas comes around more quickly each year” suggest that the passage of time between annual events can become distorted, leading to the sensation of time passing more quickly than normal. At present however, it is unclear how prevalent such beliefs are and, what factors are predictive of it. Aim To explore the prevalence of beliefs that annual events such as Christmas (Study 1 UK sample) and Ramadan (Study 2 Iraqi sample) feel like they come around more quickly each year. To establish the association between distortions to the passage of time between annual events and emotional wellbeing, event specific enjoyment, memory function and self-reported attention to time. Methods Participants c
... Show More