Abstract :- In this paper, silver nanoparticles had been prepared by chemical reduction method. Many tests had been done to it such as UV-Visible spectrophotometer, XRD, AFM&SEM test. finally an attempt had been done to get the optimum condition to control the grain size of silver Nanoparticles by variation the heating period and other parameters which has an effect in silver Nanoparticles synthesis process. in this method we can get a silver nanoparticles in the size range from 52 to 97 nm.
Abstract: In this paper, a U-shaped probe with a curvature diameter of half a centimeter was implemented using plastic optical fibers. A layer of the outer shell of the fibers was removed by polishing to a D-section. The sensor was tested by immersing it in a sodium chloride solution with variable refractive index depending on solution concentrations ranging from 1.333 to 1.363. In this design, the sensor experienced a decrease in its intensity as the concentration of the solution increased. The next step The sensor was coated with a thin layer of gold with a thickness of 20 nm, and the sensor was tested with the same solutions which resulted in a shift in wavelengths where the shift in wavelength was 5.37 nm and sensiti
... Show MoreIn this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m
... Show MoreResearch objective: This research aims to unveil how to use the method of referral in understanding the Holy Quran.
The reason for choosing the research: The one that invited me to write on this topic is the importance of the referral method, so I liked the research in it, and unveiled this wonderful Qur’anic method, so that it helps to understand the intention of God Almighty in his dear book.
The research plan: The research was divided into three topics and a conclusion.
As for the first topic, it is divided into two requirements. The first requirement deals with the definition of referral language.
In the second re
Diphenhydramine hydrochloride was determined through a newly developed turbidimetric method on a home-designed continuous-flow injection analysis (CFIA) system. The principle of the method is based on the precipitation-induced signal enhancement, using potassium hexacyanoferrate (III) as a selective precipitating agent. The CFIA manifold uses a flow-through detection cell that consists of 12 white light-emitting diodes and three solar cells placed at 0, 90 and 180 degrees in order to track cumulative light scattering over a range of angles. The systematically optimized chemical and instrumental parameters were the reagent concentration, flow rate and sample volume to attain optimal
Information and communication technology has a significant influence on employee procedures. Businesses are investing in e-CRM technologies, yet it is difficult to assess the performance of their e-CRM platforms. The DeLone and McLean Information Systems Success framework can be modified to the current e-CRM assessment difficulties. The new framework's different aspects provide a concise framework for organizing the e-CRM key metrics identified in this study. The purpose of this study is to apply and verify that the Updated DeLone and McLean IS Model can be employed to explain e-CRM adoption among employees, along with the extended Updated DeLone and McLean Model with its five output factors, namely system quality, service quality,
... Show MoreA novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%
... Show MoreThe current research aims at knowing the impact of the mind-clearing method in teaching second year intermediate students “reading book”. To achieve the study objective, the researchers intentionally chose Arjwan middle school, located in Baghdad Directorate of Education Al-Rusafa/2, which includes five classes for the second intermediate class. Division (A) was chosen randomly to represent the experimental group, which is taught in the mind-clearing method, while Division (B) represented the control group, which is taught in the traditional way. The sample of the research included (79) female students divided into (39) students in the experimental group, and (40) female students in the control group.To achieve the objective of the res
... Show More