Preferred Language
Articles
/
5hbnwYcBVTCNdQwCHl-Z
Comparing the optical parameters for thin CAZTSe films prepared with various Ag ratios and annealing temperatures
...Show More Authors

Pure Cu (CZTSe) and Ag dopant CZTSe (CAZTSe) thin films with Ag content of 0.1 and 0.2 were fabricated on coring glass substrate at R.T with thickness of 800nm by thermal evaporation method. Comparison between the optical characteristics of pure Cu and Ag alloying thin films was done by measuring and analyzing the absorbance and transmittance spectra in the range of (400-1100)nm. Also, the effect of annealing temperature at 373K and 473K on these characteristics was studied. The results indicated that all films had high absorbance and low transmittance in visible region, and the direct bang gap of films decreases with increasing Ag content and annealing temperature. Optical parameters like extinction coefficient, refractive index, and dielectric constants were estimated.

Preview PDF
Quick Preview PDF
Publication Date
Wed May 30 2018
Journal Name
International Journal Of Computer Networks & Communications
Robot Human Interface for Housekeeper Robot with Wireless Capabilities
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Quality of Life Assessment for Patients with Colorectal Cancer
...Show More Authors

Abstract A descriptive study to assess the quality of life (QOL) for patients with colorectal cancer. The study was conducted from Baghdad Teaching Hospital, Al-Yarmouk Teaching Hospital and Radiation Hospital and Nuclear medicine for the period from 1st July/2004 to 1st September/2004. The sample selected by purposive random of (50) patients diagnosed with colorectal cancer and all of them who were under chemotherapy treatment. A questionnaire was prepared for the purpose of the study and comprised of three parts including: 1- Socio-demographical characteristics. 2- Clinical characteristics. 3- and QOL

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi National Journal Of Nursing Specialties
Spiritual Coping Strategies for Patients with Chronic Renal Failure
...Show More Authors

Abstract:
Objectives: This study aims to (1) find out the association between patients' age, years of getting the disease, and their spiritual coping ability, and (2) investigate the differences in illness perception and spiritual coping ability between gender groups, level of education groups, monthly income groups, residence groups and satisfaction with health services groups.
Methodology
A descriptive correlational design is used in this study. The study sample includes a convenience sample of (158) patients with chronic kidney failure.
The study instrument consists of two parts; the first one focuses on participants’ sociodemographic characteristics, and the second part deals with participants’ spiritual coping by us

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 01 2024
Journal Name
International Journal Of Advanced And Applied Sciences
High-accuracy models for iris recognition with merging features
...Show More Authors

Due to advancements in computer science and technology, impersonation has become more common. Today, biometrics technology is widely used in various aspects of people's lives. Iris recognition, known for its high accuracy and speed, is a significant and challenging field of study. As a result, iris recognition technology and biometric systems are utilized for security in numerous applications, including human-computer interaction and surveillance systems. It is crucial to develop advanced models to combat impersonation crimes. This study proposes sophisticated artificial intelligence models with high accuracy and speed to eliminate these crimes. The models use linear discriminant analysis (LDA) for feature extraction and mutual info

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Serum Ferritin Levels for Iraqi Patients with Hashimoto's Thyroiditis
...Show More Authors

Background: The estimation of ferritin and related variables by complete serum iron profile, for Iraqi hashimoto’s patients to see the effect of thyroid hormone insufficiency, which may lead to deficiency of ferritin iron stores, this may be quite useful during the diagnosis and treatment of hashimoto’s patients. Patients and Method: The study was performed at National Center of Teaching laboratories of Medical city institute in Baghdad. Fifty newly diagnosed patients with hashimoto’s and forty apparently healthy controls. Diagnosis based on thyroid profile analysis including:Thyroid Stimulating Hormone (TSH), Thyroxine (totalT4) and Triiodothyronine (total T3), estimation of antibodies against thyroperoxidase, iron profile including:

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Transactions On Emerging Topics In Computational Intelligence
Reservoir Network With Structural Plasticity for Human Activity Recognition
...Show More Authors

View Publication
Scopus (2)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Mar 26 2022
Journal Name
Neuroquantology
Efficiency Evaluation of Optical System Includes Different Stop Apertures When Using Relative Moving Factor
...Show More Authors

In this work, optical system with different aperture shapes (circular, square, elliptical and triangle aperture) has been used for efficiency evaluation when the system involved moving factor in ideal case (aberration free). The optical system evaluate far moving object, therefore the image forming at image plane due to point spread function (image formula of incoherently illuminated point object). A mathematical treatment has been used to getting results by Gaussian numerical calculations method. The results show priority of circular aperture when optical system that submits of moving factor.

View Publication
Crossref (2)
Crossref
Publication Date
Fri Jul 01 2016
Journal Name
International Journal Of Modern Trends In Engineering And Research (ijmter)
An image processing oriented optical mark reader based on modify multi-connect architecture (MMCA)
...Show More Authors

Optical Mark Recognition (OMR) is the technology of electronically extracting intended data from marked fields, such as squareand bubbles fields, on printed forms. OMR technology is particularly useful for applications in which large numbers of hand-filled forms need to be processed quickly and with a great degree of accuracy. The technique is particularly popular with schools and universities for the reading in of multiple choice exam papers. This paper proposed OMRbased on Modify Multi-Connect Architecture (MMCA) associative memory, its work in two phases: training phase and recognition phase. The proposed method was also able to detect more than one or no selected choice. Among 800 test samples with 8 types of grid answer sheets and tota

... Show More
Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
المؤتمر العلمي التخصصي الحادي والعشرون لكلية التربية/ الجامعة المستنصرية 22-23 نيسان 2015 الفيزياء
Computer Simulations of Imaging a Dirac Delta Function by a Ground-Based Optical Telescope
...Show More Authors

Two- dimensional numerical simulations are carried out to study the elements of observing a Dirac point source and a Dirac binary system. The essential features of this simulation are demonstrated in terms of the point spread function and the modulation transfer function. Two mathematical equations have been extracted to present, firstly the relationship between the radius of optical telescope and the distance between the central frequency and cut-off frequency of the optical telescope, secondly the relationship between the radius of the optical telescope and the average frequency components of the modulation transfer function.

Preview PDF
Publication Date
Sat Dec 31 2022
Journal Name
Pakistan Journal Of Medical And Health Sciences
A Computer Simulation of Hubble Telescope Including Eyepiece Nano- Sensors to Increase Optical Efficiency
...Show More Authors

The Hubble telescope is characterized by the accuracy of the image formed in it, as a result of the fact that the surrounding environment is free of optical pollutants. Such as atmospheric gases and dust, in addition to light pollution emanating from industrial and natural light sources on the earth's surface. The Hubble telescope has a relatively large objective lens that provides appropriate light to enter the telescope to get a good image. Because of the nature of astronomical observation, which requires sufficient light intensity emanating from celestial objects (galaxies, stars, planets, etc.). The Hubble telescope is classified as type of the Cassegrain reflecting telescopes, which gives it the advantage of eliminating chromat

... Show More
View Publication
Crossref