Preferred Language
Articles
/
4xaBaIgBVTCNdQwCp3aI
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer Lens Implantation for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluated during a 12 months follow-up period include UDVA, refractive outcomes, CDVA, vault and adverse events. Results: At 12 months postoperatively, the mean Snellen decimal UDVA was 0.77±0.23 and the mean CDVA was 0.80±0.21, with an efficacy index of 1.16. Twenty nine eyes (48.33%) showed gain in CDVA with a safety index of 1.21. The treatment was highly predictable for spherical equivalent and astigmatic component. The mean SE dropped from -12.63±3.11 D to -0.11±0.20 D with 58 eyes within ±0.50 D and 60 eyes with ±1.00 D of the target correction. For achieved cylinder 60 eyes (100%) had ≤0.50 D and 51 eyes (85%) had ≤0.25 D with a strong positive linear correlation between achieved and expected cylinder (r=0.94). Conclusion: The results of the present study support safety, efficacy, predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism Abbreviation: UDVA: uncorrected distance visual acuity, CDVA: corrected distance visual acuity, SE: spherical equivalent and ACD: anterior chamber depth

Crossref
View Publication
Publication Date
Sun Apr 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Design of Electrostatic Unipotential Lens Accelerating And Decelerating Operated Under Finite And Infinite Magnification Conditions
...Show More Authors

  Theoretical study computerized has been carried out in field electron optics , to design electrostatic unipotential lens , the inverse problem is important method in the design of electrostatic lenses by suggesting an axial electrostatic potential distribution using polynomial function. The paraxial –ray equation is solved to obtain the trajectory particles that satisfy the suggested potential function. In this research , design electrostatic unipotential lens three-electrode accelerating and decelerating L=5 mm operated under finite and infinite magnification conditions. The electrode shape of the electrostatic lens was then determined from the solution of the Laplace's equation's. the results showed low values of spherica

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Cranio-maxillofacial Surgery
Assessment of regional asymmetry of the face before and after surgical correction of unilateral cleft lip
...Show More Authors

View Publication
Scopus (19)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Embryonic Development of Eye Lens in Mosquito fish Gambusia affinis (Baird and Girard, 1853)
...Show More Authors

The embryonic development of the Mosquito fish(Gambusia affinis) eye lens was investigated using light microscopy .The results indicated that the embryonic development of the lens does not correspond to that of the non spherical lenses of terrestrial vertebrates .This study showed that a very small cavity in the lens vesicle appears during development ,but it differs from that of the mammalian lens. The most important aspect in this study is that ,the posterior edge of the simple cuboidal epithelium which covers the anterior half of the surface of the lens is situated well beyond the equatorial region of the lens .As a result , the germinal and transitional zones became closer to the posterior pole rather than the anterior pole of the le

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 05 2024
Journal Name
The Journal Of Obstetrics And Gynecology Of India
Obstetric and Neonatal Outcomes in Overweight Adolescent Pregnant Mothers
...Show More Authors

Background The escalating global concern over increased body weight in adolescents, coupled with the rising rates of adolescent pregnancy worldwide, presents a significant challenge to healthcare systems. We plan to identify the maternal and neonatal consequences associated with pre-pregnancy overweight in adolescent women. Methods Throughout five years, all singleton adolescent pregnant women with pre-pregnancy self-reported body mass index (BMI) of 18.5– ≤ 29.9 were involved during the first-trimester visit. Two groups were generated: overweight and appropriate-weight (BMI 25–29.9 and 18.5–24.9, respectively). Obstetric and neonatal outcomes were observed prospectively and statistically adjusted for the confounding factors.

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Mar 05 2024
Journal Name
The Journal Of Obstetrics And Gynecology Of India
Obstetric and Neonatal Outcomes in Overweight Adolescent Pregnant Mothers
...Show More Authors

Background The escalating global concern over increased body weight in adolescents, coupled with the rising rates of adolescent pregnancy worldwide, presents a significant challenge to healthcare systems. We plan to identify the maternal and neonatal consequences associated with pre-pregnancy overweight in adolescent women. Methods Throughout five years, all singleton adolescent pregnant women with pre-pregnancy self-reported body mass index (BMI) of 18.5– ≤ 29.9 were involved during the first-trimester visit. Two groups were generated: overweight and appropriate-weight (BMI 25–29.9 and 18.5–24.9, respectively). Obstetric and neonatal outcomes were observed prospectively and statistically adjusted for the confounding factors.

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jul 06 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Teenage pregnancy. Prevalence and adverse outcomes in Baghdad city
...Show More Authors

Pregnancy at an early age of life is a major challenge. The consequences of this problem have an impact on the quality of life of the young mother and her family, and determines an important risk for her offspring. The son of a teenage mother has, in general, greater risks than that of a mother of more than 20 years. The aim of this study is to determine the prevalence and outcome of teenage pregnancy. A descriptive data base study was conducted at Al-Elwia Maternity Teaching hospital in the period from January 1, 2019 to the end of June 2019 within the age between 12 and 19 years old. The mean age of the mother was 17.4 ±1.5 years. The mean age of the father was 23.9 ± 5.7 years with (69.5%) with Vaginal delivery and most of the

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Apr 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Magnetic Lens Design Using Analytical Target Field Function
...Show More Authors

Analytical field target function has been considered to represent the axial magnetic field distribution of double polepiece symmetric magnetic lens. In this article, with aid of the proposed target function, the syntheses procedure is dependent. The effect of the main two coffectin optimization parameters on the lens field distribution, polepieces shape, and the objective focal prosperities for lenses operated under zero magnification mode has been studied. The results have shown that the objective properties evaluated in sense of the inverse design procedure are in an excellent correspondence with that of analysis approach. Where the optical properties enhance as the field distribution of the electron lens distributed along a narrow axi

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 07 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Relationship of Low Maternal Vitamin D3 Level and Adverse Early Neonatal Outcomes
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 24 2017
Journal Name
Iraqi Journal Of Laser
All Fiber Chemical Liquids Refractive Index Sensor Based on Multimode Interference
...Show More Authors

A simple all optical fiber sensor based on multimode interference (MMI) for chemical liquids sensing was designed and fabricated. A segment of coreless fiber (CF) was spliced between two single mode fibers to buildup single mode-coreless-single mode (SCS) structure. Broadband source and optical signal analyzer were connected to the ends of SCS structure. De-ionized water, acetone, and n-hexane were used to test the performance of the sensor. Two influence factors on the sensitivity namely the length and the diameter of the CF were investigated. The obtained maximum sensitivity was at n-hexane at 340.89 nm/RIU (at a wavelength resolution of the optical spectrum analyzer of 0.02 nm) when the diameter of the CF reduced from 125 μm to 60 μ

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 10 2018
Journal Name
Commun.fac.sci.univ.ank.series A2-a3
ULTRAHIGH SENSITIVE REFRACTIVE INDEX SENSOR BASED ON TAPERED MULTICORE OPTICAL FIBER
...Show More Authors

The refractive index sensors based on tapered optical fiber are attractive for many industries due to sensing capability in a variety of application. In this paper, we proposed a refractive index sensor based on multicore fiber (MCF) sandwiched between two standard single mode fibers (SMF). The sensor consisting of three sections, SMF- MCF-SMF is structurally simple and can be easily produced by joining these parts. The MFC contains seven cores and these cores are surrounded by a single cladding. The sensing region is obtained by tapering the MCF section where the evanescent field is generated. The single mode propagating along the SMF is stimulated at the first joint and is coupled to the cladding modes. These modes interfere with the core

... Show More