Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluated during a 12 months follow-up period include UDVA, refractive outcomes, CDVA, vault and adverse events. Results: At 12 months postoperatively, the mean Snellen decimal UDVA was 0.77±0.23 and the mean CDVA was 0.80±0.21, with an efficacy index of 1.16. Twenty nine eyes (48.33%) showed gain in CDVA with a safety index of 1.21. The treatment was highly predictable for spherical equivalent and astigmatic component. The mean SE dropped from -12.63±3.11 D to -0.11±0.20 D with 58 eyes within ±0.50 D and 60 eyes with ±1.00 D of the target correction. For achieved cylinder 60 eyes (100%) had ≤0.50 D and 51 eyes (85%) had ≤0.25 D with a strong positive linear correlation between achieved and expected cylinder (r=0.94). Conclusion: The results of the present study support safety, efficacy, predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism Abbreviation: UDVA: uncorrected distance visual acuity, CDVA: corrected distance visual acuity, SE: spherical equivalent and ACD: anterior chamber depth
ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear imp
... Show MoreBACKGROUND: Keratoconus is a progressive non inflammatory bilateral (usually asymmetric) ectatic corneal disease characterized by paraxial stromal thinning ,weakening that lead to corneal surface distortion ,vision loss primarily from irregular astigmatism and myopia and secondly from corneal scar. OBJECTIVE: To evaluate visual and refractive outcomes after intracorneal continuous ring (ICCR) implantation combined with intrapocket corneal collagen cross linking in patient with keratoconus. Setting: Eye Specialty Private Hospital, Baghdad, Iraq. METHODS: This study assessed the results of implantation of Myoring ICCR combined with CXL in 40 eyes with KC. Outcome measures include UDVA,CDVA(spectacle correction),refraction, complications and s
... Show MoreThe GPS navigation measurements become more widely used in many civilian and scientific application. All GPS navigation data holds many errors, the main error sources arise from the geodetic Datum variation when user apply the GPS measurements with the map. Geodetic datums define the size and shape of the earth and the origin and orientation of the coordinate systems used to map the earth surface. In this paper, the Datum transformation was evaluated in two mathematical methods to overcome the errors due to the difference between the WGS-84 and our country Datum Clarck-1880. The results was evaluated and investigated using Carmin GPS device for GCPs comparison, topographic map for Hilla city, mid Iraq 1:100000 scale, and two georefrencing
... Show MoreIn this article it is proved experimentally that the photon is a particle that has mass and constant wavelength by explaining the effect of refractive index on the wavelength and the natural mass of photon. It is very difficult to measure the mass of photon, a simple and easy process was proposed in this paper to calculate the mass length of photon in vacuum (Y) and in medium (Y*), by measuring the length of laser beam in air (Lair) and in medium (Lmed). A new method was postulated to calculate refractive index by using these relations (n = Y*/Y), and (n = Lmed / Lair) which supposed a new theory of light.
Transient drop in the heart beat or transient heart block (AVB) may be consider the main cause of syncope or presyncope inpatients with bifascicular block and syncope According to the Guidelines for cardiac pacing pacemaker consider part of treatment. Aims of our study were to evaluate whether there is role for EPS in patients BFB and to evaluate the symptoms after pacing. 42 patients were enrolled in this study, with mean age value (63.4± 12.2years), suffer from interventricular conductive defect and syncope; patients underwent EPS on admission time, and pacemaker implantation accordingly and programmed follow up for the device in the last four years. Our patients were 25 (59.5%) male and 17 (40.5%)female, all of them with syncope o
... Show MoreThe shell model calculations with Cohen-Kurath (C-K) interaction were carried out to investigate form factors of elastic transverse electron scattering, and magnetic dipole-moments of odd 7,9,11Be isotopes. The effect of the exact value of center of mass correction was adopted to generate the magnetic form factors in Born approximation picture. The contribution of the higher 2p-shell configuration was included to reproduce the experimental data. A significant improvement was obtained in the present results with core-polarization (CP) effect through the effective g-factors. The occupancies percentage with respect to the valence nucleons was also calculated.
Many problems are facing the installation of piles group in laboratory testing and the errors in results of load and settlement are measured experimentally may be happened due to select inadequate method of installation of piles group. There are three main methods of installation in-flight, pre-jacking and hammering methods. In order to find the correction factor between these methods the laboratory model tests were conducted on small-scale models. The parameters studied were the methods of installation (in-flight, pre-jacking and hammering method), the number of piles and in sandy soil in loose state. The results of experimental work show that the increase in the number of piles value led to increase in load carrying capacity of piled raft
... Show MoreMany problems are facing the installation of piles group in laboratory testing and the errors in results of load and settlement are measured experimentally may be happened due to select inadequate method of installation of piles group. There are three main methods of installation in-flight, pre-jacking and hammering methods. In order to find the correction factor between these methods the laboratory model tests were conducted on small-scale models. The parameters studied were the methods of installation (in-flight, pre-jacking and hammering method), the number of piles and in sandy soil in loose state. The results of experimental work show that the increase in the number of piles value led to increase in load carrying ca
... Show More