Preferred Language
Articles
/
4hZf74oBVTCNdQwC5ajr
STUDY ON THE PARAMETER OPTIMIZATION INMAGNETIC ABRASIVE POLISHING FORBRASS CUZN33PLATE USING TAGUCHI METHOD
...Show More Authors

This paper describes a new finishing process using magnetic abrasives were newly made to finish effectively brass plate that is very difficult to be polished by the conventional machining processes. Taguchi experimental design method was adopted for evaluating the effect of the process parameters on the improvement of the surface roughness and hardness by the magnetic abrasive polishing. The process parameters are: the applied current to the inductor, the working gap between the workpiece and the inductor, the rotational speed and the volume of powder. The analysis of variance(ANOVA) was analyzed using statistical software to identify the optimal conditions for better surface roughness and hardness. Regressions models based on statistical mathematical approach by using the MINITAB-statistical software for both surface roughness and hardness were obtained. Experimental results indicated that rotational speed is the most significant parameters on change in surface roughness(ΔRa), and for change in surface hardness (ΔHa), volume of powder is the significant one. As a result, it was seen that the magnetic abrasive polishing was very useful for finishing the brass alloy plate.

View Publication
Publication Date
Thu Jan 01 2009
Journal Name
Ibn Al- Haitham J. Fo R Pure & Appl. Sci
Multiple Mixing Ratios of Gamma Rays Erγ)nEr(n, From 168 168 Reaction  Using a2 – Ratio Method
...Show More Authors

The -mixing of  - transition in Er 168 populated in Er)n,n(Er 168168  reaction is calculated in the present work by using a2- ratio method. This method has used in previou studies [4, 5, 6, 7] in case that the second transition is pure or for that transition which can be considered as pure only, but in one work we applied this method for two cases, in the first one for pure transition and in the 2nd one for non pure transitions. We take into accunt the experimental a2- coefficient for p revious works and -values for one transition only [1]. The results obtained are, in general, in agood agreement within associated errors, with those reported previously [1], the discrepancies that occur are due to inaccuracies existing

... Show More
Publication Date
Fri Jan 01 2010
Journal Name
Ibn Al- Haitham J. Fo R Pure & Appl. Sci
Multipole Mixing Ratios of Gamma Rays From Fe(n,ny Reaction Using Constant Statistical Tensor Method (CST).
...Show More Authors

The - M ultiple mixing ratios of -transitions from levels of 56Fe populated in 56 56 Fe n n Fe ( , )  reactions are calculated by using const. S.T.M. This method has been used in other works [3,7] but with pure transition or with transitions that can be considered as pure transitions، in our work we used This method for mixed  - transitions in addition to pure  - transitions. The experimental angular distribution coefficients a2 was used from previous works [1] in order to calculet - values. It is clear from the results that the - values are in good agreement or consistent, within associated errors, with those reported previously [1]. The discrepancies that occur are due to inaccuracies existing in the expe

... Show More
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jul 01 2013
Journal Name
Diyala Journal For Pure Sciences
Multipole Mixing Ratios for Gamma transitions in 56Fe populated in Reaction by using least square fitting method .
...Show More Authors

The γ- mixing ratios of γ- transitions from levels of 56Fe populated in reaction are calculated using least square fitting program for the first time in the case of pure and mixed transitions the results obtained have been compound with γ Values determined by other methods .The comparison shows that the agreement is good this confirmed the valilety of this method in calculating of values for such γ- transitions key word: γ- transition ,Multipole mixing ratios ,Least square fitting method.

Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Genetic Variations of Echinococcus granulosus Isolated from Sheep and Cows by Using Fingerprint DNA Method in Iraq
...Show More Authors

The fingerprinting DNA method which depends on the unique pattern in this study was employed to detect the hydatid cyst of Echinococcus granulosus and to determine the genetic variation among their strains in different intermediate hosts (cows and sheep).  The unique pattern represents the number of amplified bands and their molecular weights with specialized sequences to one sample which different from the other samples.   Five hydatitd cysts samples  from cows and sheep were  collected, genetic analysis for  isolated DNA was done using PCR technique and  Random Amplified Polymorphic DNA reaction(RAPD) depending on (4) random primers, and the results showed:      

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Spectrophotometric Determination of Nifedipine in Pharmaceutical Tablets Using Batch and Flow Injection Method Via Diazotization Coupling Reaction
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
A Direct Solution Scheme for Wide-Angle Electromagnetic Scattering Problems Using Compressive Sensing-Based Method of Moments
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Physics: Conference Series
Synthesis of Silver Nanoparticles by ecofriendly nvironmental method using Piper nigrum, Ziziphus spina-christi, and Eucalyptusglobulus extract
...Show More Authors
Abstract<p>In the present study, silver nanoparticles (AgNPs) were prepared using an eco-friendly method synthesized in a single step biosynthetic using leaves aqueous extract of Piper nigrum, Ziziphus spina-christi, and Eucalyptus globulus act as a reducing and capping agents, as a function of volume ratio of aqueous extract(100ppm) to AgNO3 (0.001M), (1: 10, 2: 10, 3: 10). The nanoparticles were characterized using UV-Visible spectra, X-ray diffraction (XRD). The prepared AgNPs showed surface Plasmon resonance centered at 443, 440, and 441 nm for sample prepared using extract Piper nigrum, Ziziphus spina-christi, and Eucalyptus respectively. The XRD pattern showed that the strong intense peaks</p> ... Show More
View Publication
Scopus (15)
Crossref (6)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Ieee Antennas And Wireless Propagation Letters
Stabilized and Fast Method for Compressive-Sensing-Based Method of Moments
...Show More Authors

View Publication
Scopus (14)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Fri Apr 30 2010
Journal Name
Journal Of Applied Computer Science & Mathematics
Image Hiding Using Magnitude Modulation on the DCT Coefficients
...Show More Authors

In this paper, we introduce a DCT based steganographic method for gray scale images. The embedding approach is designed to reach efficient tradeoff among the three conflicting goals; maximizing the amount of hidden message, minimizing distortion between the cover image and stego-image,and maximizing the robustness of embedding. The main idea of the method is to create a safe embedding area in the middle and high frequency region of the DCT domain using a magnitude modulation technique. The magnitude modulation is applied using uniform quantization with magnitude Adder/Subtractor modules. The conducted test results indicated that the proposed method satisfy high capacity, high preservation of perceptual and statistical properties of the steg

... Show More
View Publication Preview PDF