Preferred Language
Articles
/
4hYYGYcBVTCNdQwCoDbN
Performance evaluation of the photovoltaic thermal system with a fin array and surface zigzag layout
...Show More Authors
Abstract<p>Solar photovoltaic (PV) has many environmental benefits and it is considered to be a practical alternative to traditional energy generation. The electrical conversion efficiency of such systems is inherently limited due to the relatively high thermal resistance of the PV components. An approach for intensifying electrical and thermal production of air-type photovoltaic thermal (PVT) systems via applying a combination of fins and surface zigzags was proposed in this paper. This research study aims to apply three performance enhancers: case B, including internal fins; case C, back surface zigzags; and case D, combinations of fins and surface zigzags; whereas the baseline smooth duct represents case A. A 2D, steady-state simulation model that took into account the impact of the convective flow of air circulating inside the PVT system in addition to radiative and convective heat losses from the front PV surface was developed and validated via previous tests. The results revealed that, under the same volume requirements, the application of surface zigzags is preferred for airflow rates of 0.06 kg/s or less, whereas the introduction of fins is preferred for higher airflow rates. The results also revealed that, of the three cases considered, the introduction of the fin–surface zigzag combination is the most effective and has the potential to improve the electrical and thermal efficiency by ~26% and 3%, respectively.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jan 01 2015
Journal Name
Health
Evaluation of Myocardial Performance in Hypertensive Patients with Type 2 Diabetes and Normal Ejection Fraction
...Show More Authors

View Publication
Crossref
Publication Date
Mon Dec 05 2022
Journal Name
Baghdad Science Journal
Influence of Optical Fiber Diameters on the Performance of Surface Plasmon Resonance Sensor
...Show More Authors

In this research, a sensor for chemical solutions was designed and formed using optical fiber-based on a surface Plasmon resonance technology. A single-mode optical fiber with three different diameters (25, 45 and 65) µm was used, respectively.  The second layer of the low refractive fiber was replaced by gold, which was electrically deposited at 40 µm thickness. For each of the three types of optical fiber, different saline concentrations (different index of refraction) were used to evaluate the performance of the refractive index sensor (chemical sensor) by measuring its sensitivity and resolutions. The highest values we could get for these two parameters were 240mm/RIU, and 6*10-5 RIU respectively, when the diameter of a

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Hoisting System Performance
...Show More Authors

In this paper it is required to enhance the performance of a mechanical system (here: a Hoisting System) where it is preferred to lift a different payloads with approximately the same speed of lifting and keeping at the same time the good performance, and this of course needs some intelligence of the system which will be responsible on measuring the present load and taking into account the speed and performance desired in order to achieve the requirements or the criteria. The process therefore is a Mechatronics System design which includes a measuring system, a control or automation technique, and an actuating system. The criteria built here in this research using a given Hoist system's characteristics and parameters and changing one of

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 22 2019
Journal Name
Baghdad Science Journal
Geometry, and Normal Modes of Vibration (3N-6) for Di and Tetra-Rings Layer (6, 0) Linear (Zigzag) SWCNTs; A DFT Treatment
...Show More Authors

            Density Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequ

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Ndt &amp; E International
Porosity evaluation of in-service thermal barrier coated turbine blades using a microwave nondestructive technique
...Show More Authors

View Publication
Scopus (20)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Directive and Steerable Radiation Pattern using SASPA Array
...Show More Authors

This work examines the ability of a special type of smart antenna array known as Switched Active Switched Parasitic Antenna (SASPA) to produce a directive and electronically steerable radiation pattern. The SASPA array consists of antenna elements that are switchable between active and parasitic states by using P-Intrinsic-N (PIN) diodes. The active element is the element that is supplied by the radio frequency while short-circuiting the terminals of an element in the array results in a parasitic element. Due to the strong mutual coupling between the elements, a directional radiation pattern with high gain and a small beamwidth can be produced with only one active element operating at a time. By changing the parasitic state to the active

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 04 2022
Journal Name
Journal Of Nanomaterials
Thermal Management of the Melting Process in a Latent Heat Triplex Tube Storage System Using Different Configurations of Frustum Tubes
...Show More Authors

In this study, the energy charging mechanism is mathematically modeled to determine the impact of design modifications on the thermofluidic behavior of a phase change material (PCM) filled in a triplex tube containment geometry. The surface area of the middle tube, where the PCM is placed, is supported by single or multi-internal frustum tubes in vertical triplex tubes to increase the performance of the heating and cooling of the system. In addition to the ordinary straight triplex tubes, three more scenarios are considered: (1) changing the middle tube to the frustum tube, (2) changing the inner tube to the frustum tube, and (3) changing both the internal and central tubes to the frustum tubes. The impact of adopting the tube desig

... Show More
View Publication
Scopus (52)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Performance of Solar Adsorption Cooling System Using Methanol and Activated Carbon as a Working Pair
...Show More Authors

The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Performance Evaluation of a Combined Electrocoagulation– Electrooxidation Process for the Treatment of Petroleum Refinery Wastewater
...Show More Authors
Abstract<p>The present study investigates the application of a combined electrocoagulation-electrooxidation (EC-EO) process for the treatment of wastewater generated from Al-Dewaniya petroleum refinery plant in Iraq. The EC-EO process was examined in terms of its ability to simultaneously produce coagulant and oxidant agents by using a parallel plate configuration system composed of stainless steel plates as cathode and pair of aluminum and graphite plates as anode at two different current concentrations (1.92A/l and 0.96A/l). The results showed that the best conditions for treatment of Al-Dewaniya petroleum refinery wastewater using the combined approach were current concentration of (0.96A/l), current density</p> ... Show More
View Publication
Crossref (8)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref