Preferred Language
Articles
/
1hdgUpEBVTCNdQwCQ5RF
Optical Power Distributions for 4×4 MIMO Visible Light Communications in Indoor Environment
...Show More Authors

Visible Light Communication (VLC) has emerged as a powerful technique for wireless communication systems. Providing high data rate and increasing capacity are the major problems in VLC. Recent evidence suggests that Multiple Input Multiple Output (MIMO) technique can offers improved data rates and increased link range. This paper describes the design and implementation of visible light communication system in indoor environment exploring the benefits of MIMO. The specific objective of this research was to implement a 4× 4 Multiple Input (LEDs) Multiple Output (photodetectors)-VLC communication system, where a 16 white power LEDs in four arrays are setting up at transmitter and four RX modules are setting up at receiver side without the need for additional power or bandwidth as well as analyze a mathematical model for a VLC-× 4 MIMO with different modes such as the suitable angles to cover the entire room. The research designs practically an electronic circuit for the transmitter and receiver with inexpensive components. The power distribution of different propagation modes is calculated for Single Input Single Output (SISO) and MIMO channels in typical room dimensions. The results in this paper indicate that the power is distributed uniformly for entire room when implemented VLC-MIMO as compared to VLC-SISO. Furthermore, a 4× 4 MIMO implementing VLC is compared in term of BER vs. SINR with SISO communication system for both Line of Sight (LOS) and Non Line of Sight (NLOS) propagation modes. Comparing the two results of LOS and NLOS, it can be seen that a 4× 4 MIMO implementing VLC for LOS perform better …

Scopus Crossref
View Publication
Publication Date
Tue Feb 04 2014
Journal Name
Al-mustansiriyah
Synthesis, Spectroscopic and Biological Studies of some Metal Complexes with 2, 4-dinitro-2-amino hydrozo benzene.
...Show More Authors

Publication Date
Sat Oct 19 2024
Journal Name
Baghdad Science Journal
Synthesis, Characterization and Biological Activity of New Ligand     Derived from 4-‎(Dimethylamino) Benzaldehyde and Nano Copper Complex
...Show More Authors

الصيغة العامة للمعقدات الجديدة [M2(BDS)Cl4] الناتجة من تفاعل الليكاند الجديد] ن1,ن4-ثنائي(1أ –بنزو]د[ اميدازول-2-يل)-ن1,ن4-ثنائي(4-ثنائي مثيل امينو) بنزيل) سكسنمايد[ (BDS) مع الايونات الفلزية الكادميوم, الكوبلت, الزئبق, النحاس والنيكل. تم اشتقاق هذا الليكاند من تفاعل المواد الثلاث 4-(ثنائي ميثيل أمينو) بنزالدهيد، 2-أمينو بنزيميدازول، وكلوريد السكسينيل. تم تشخيص المركبات باستخدام مطيافية طيف الاشعة تحت الحمراء وطيف الرن

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sat Dec 03 2016
Journal Name
Journal Of Genetic And Environmental Resources Conservation
Examination the efficiency of NDVI index by comparing with STVI-4 index to recognize the vegetation cover
...Show More Authors

Publication Date
Sun Jul 01 2018
Journal Name
Journal Of Global Pharma Technology
Synthesis of New 2, 4, 5-triphenyl imidazole Derivatives Derived from benzoin and Studying their Biological Activity
...Show More Authors

compound [1] was formed from the reaction of benzoin and benzaldehyde in the presence of ammonia, which was reacted with sodium hydride in DMF to obtain imidazole salt. This salt was reacted with adipoyl chloride to give compound [2]. Acid hydrazide derivative [3] was obtained from the reaction of compound [2] with hydrazine hydrate. After that Shiff bases [4-9] have been synthesized from the reaction of compound [3] with different aromatic aldehydes. These new formed compounds were diagnosed by 13C-NMR, 1H-NMR for some of them (in Ahl-Albate University in Jordan) and FT-IR spectroscopy (In Baghdad University). All of the prepared products have been studied their biological activities toward two kinds of bacteria. These products show

... Show More
Scopus (7)
Scopus
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Compact MIMO Slots Antenna Design with Different Bands and High Isolation for 5G Smartphone Applications
...Show More Authors

 In this paper, two elements of the multi-input multi-output (MIMO) antenna had been used to study the five (3.1-3.55GHz and 3.7-4.2GHz), (3.4-4.7 GHz), (3.4-3.8GHz) and (3.6-4.2GHz) 5G bands of smartphone applications that is to be introduced to the respective US, Korea, (Europe and China) and Japan markets. With a proposed dimension of 26 × 46 × 0.8 mm3, the medium-structured and small-sized MIMO antenna was not only found to have demonstrated a high degree of isolation and efficiency, it had also exhibited a lower level of envelope correlation coefficient and return loss, which are well-suited for the 5G bands application. From the fabrication of an inexpensive FR4 substrate with a 0.8 mm thickness level, a loss tang

... Show More
View Publication Preview PDF
Scopus (10)
Scopus Clarivate Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Prepare a plan for the Total Productive Maintenance in the light of the concurrent engineering A Field Study in AL-Askandria General Company Machanical Industries and AL-Musaib Electric Power Station
...Show More Authors

           Strives Total Productive Maintenance  to increase the overall effectiveness of the equipment through the early involvement in the design and manufacture of equipment productivity. It also operates in an environment of simultaneous engineering work on the synchronization of activities to take advantage of early information by maintenance engineers, design, operation, and that helps to reduce the faults and facilitate future maintenance tasks.

    Has adopted a search in the theoretical concept of the total maintenance productivity and concurrent engineering activities carried out during which the conjunction a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed May 01 1985
Journal Name
International Journal Of Mass Spectrometry And Ion Processes
Energy distributions of atmospheric ions drifting in rare gases
...Show More Authors

View Publication
Scopus (15)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Ieee Access
6G Wireless Communications Networks: A Comprehensive Survey
...Show More Authors

View Publication
Scopus (364)
Crossref (352)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2010
Journal Name
International Journal Of Advancements In Computing Technology
Implementation of digital chaotic signal generator based on reconfigurable LFSRs for multiple access communications
...Show More Authors

This paper describes the digital chaotic signal with ship map design. The robust digital implementation eliminates the variation tolerance and electronics noise problems common in analog chaotic circuits. Generation of good non-repeatable and nonpredictable random sequences is of increasing importance in security applications. The use of 1-D chaotic signal to mask useful information and to mask it unrecognizable by the receiver is a field of research in full expansion. The piece-wise 1-D map such as ship map is used for this paper. The main advantages of chaos are the increased security of the transmission and ease of generation of a great number of distinct sequences. As consequence, the number of users in the systems can be increased. Rec

... Show More
Scopus (3)
Scopus
Publication Date
Sun Dec 03 2017
Journal Name
Al-khwarizmi Engineering Journal
A theoretical study for increasing production of electric power from Iraqi steam power plants.
...Show More Authors

This article conclude a theoretical study for the possibility to produce additional electric power from Iraqi steam power plants by  cutting – off high-pressure feed water heaters .  Three separated steam power plants which Dura , south –Baghdad and Nasria were studied . The investigation showed the possibity of increasing the electric power from 10 to 15% for Dura and Nasria , whereas 6% for south – Baghdad . According to the nowadays of operation to Iraqi steam power plants , the results showed that by cutting–off high  pressure feed water heaters we can generate additional electric power about 250 MW during 3-4 hrs. daily. In addition, the fuel consumption can be reduced in comparison with diesel generat

... Show More
View Publication Preview PDF