Objectives To assess the feasibility and accuracy of a new prototype robotic implant system for the placement of zygomatic implants in edentulous maxillary models. Methods The study was carried out on eight plastic models. Cone beam computed tomographs were captured for each model to plan the positions of zygomatic implants. The hand-eye calibration technique was used to register the dynamic navigation system to the robotic spaces. A total of 16 zygomatic implants were placed, equally distributed between the anterior and the posterior parts of the zygoma. The placement of the implants (ZYGAN®, Southern Implants) was carried out using an active six-jointed robotic arm (UR3e, Universal Robots) guided by the dynamic navigation coordinate transformation matrix. The accuracy of the implant placement was assessed using EvaluNav and GeoMagicDesignX® software based on pre- and post-operative CBCT superimposition. Descriptive statistics for the implant deviations and Pearson's correlation analysis of these deviations to force feedback recorded by the robotic arm were conducted. Results The 3D deviations at the entry and exit points were 1.80 ± 0.96 mm and 2.80 ± 0.95 mm, respectively. The angular deviation was 1.74 ± 0.92°. The overall registration time was 23.8 ± 7.0 min for each side of the model. Operative time excluding registration was 66.8 ± 8.8 min for each trajectory. The exit point and angular deviations of the implants were positively correlated with the drilling force perpendicular to the long axis of the handpiece and negatively correlated with the drilling force parallel to the long axis of the handpiece. Conclusion The errors of the dynamic navigation-guided robotic placement of zygomatic implants were within the clinically acceptable limits. Further refinements are required to facilitate the clinical application of the tested integrated robotic-dynamic navigation system. Clinical significance Robotic placement of zygomatic implants has the potential to produce a highly predictable outcome irrespective of the operator's surgical experience or fatigue. The presented study paves the way for clinical applications.
In this work, studying the effect of ethylenediamine as a corrosion inhibitor was investigated for carbon steel in aerated HCl solution in range of 0.1-1N under dynamic conditions, i.e., rotational velocity of 400–1200 rpm in the temperature range 35 – 65 ºC. Weight loss method was employed in absence and presence of the inhibitor as an adsorption type in concentration range 1000 – 5000 ppm using rotating cylinder specimens. The experimental results showed that corrosion rate in absence and presence of inhibitor is increased with increasing temperature, rotational velocity and concentration of acid. It is decreased with increasing inhibitor concentration for the whole range of temperature, rotational velocity and concentrati
... Show MoreIn this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. In order to investigate the response of soil and footing to steady state dynamic loading, a physical model was manufactured to simulate steady state harmonic load at different operating frequencies. Total of 84 physical models were performed. The footing parameters are related to the size of the rectangular footing and depth of embedment. Two sizes of rectangular steel model footing were tested at the surface and at 50 mm depth below model surface. Meanwhile the investigated parameters of the soil condition include dry and saturated sand for two relative densities 30% and 80%. The response of the footing was ela
... Show MoreABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib
... Show MoreDetermining risk indicators for dental implants is an essential strategy for preventing peri-implant diseases and effective diagnosis of dental implant success. To investigate the impact of certain potential factors on the osseointegrated dental implant. Eighty-four individuals were included in our study, 50 cases as a patient’s group and 34 participants as a control group. All cases were diagnosed based on certain criteria, 30 (60%) of patients had peri-implantitis, 20 (40%) with severe periimplantitis, 36(72%) were generalized, and 15 (30%) as localized peri-implantitis cases. The study has indicated that 44.7% of dental implants were in the anterior maxilla, followed by (27.3%) posterior maxilla, (17.4%) posterior mandible, and (10.4%)
... Show MoreThe article describes a study on the role of vitamin C as a protective agent for the teeth, gum, and implants using quantum chemical calculations and polarization tests. The Density Functional Theory (DFT) at 6-311G (d, p) basis set is used to estimate the ability of vitamin C to inhibit the corrosion of the abovementioned parts. The experimental study was performed in a at human body media simulator (Hank’s balanced salt solution) at a temperature of 37°C. The compound was optimized for its ground state, physical properties, and corrosion parameters. Further, HOMO, LUMO, energy gap, dipole moment, and other parameters were used to predict the inhibitor’s efficiency. Gaussian 09, UCA-FUKUI, MGL tools, DSV, and LigPlus software was used
... Show MoreAbstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,
... Show MoreBackground: Dental implant considers a unique treatment option for the replacement of missing dentition. The new trend of implants is looking for materials which accelerate bone formation in bone implant interface and enhance osseointegration to provide immediate loading directly after placement and decrease the time period which is disturbs patients and uncomfortable. The aim of the study was to evaluate the effect of nano zirconium oxide (ZrO2) and nano hydroxyapatite (Hap) mixture coating of screw shaped commercially pure titanium (cpTi) implants on bond strength at the bone implant interface with torque removal test and histological analysis in comparison with non coated implants. Materials and methods: Forty screws were machined from c
... Show More