Preferred Language
Articles
/
0BeMX5MBVTCNdQwCfNJi
A hand-held hybrid gamma-near-infrared fluorescence imaging camera

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamma small field of view camera, capable of displaying co-aligned images from both modalities, which can be fused into one image or viewed separately. This study is a preliminary investigation of the performance of the fluorescence component of this camera, including phantom studies and first images from a preclinical pilot study. Methods: The hybrid camera consists of a 1500 µm thick thallium doped caesium iodide columnar (CsI:Tl) scintillator coupled to an electron multiplying charged coupled device (EMCCD). A 1.0mm diameter tungsten pinhole collimator gives a 40mm x 40mm nominal field of view for an 8mm x 8mm CCD detection area. A fluorescence camera was aligned to provide the same field of view as the gamma camera with an LED ring as the excitation source. The performance of the fluorescence imaging was quantified in this study for the fluorophores ICG and IRDye800CW (CW800) using a range of bespoke phantom experiments. In vivo images were also obtained from a preclinical study of a targeted hybrid tracer (cRGD-CW800-TCO + TCO-DOTA-111In) in mice with HT29 colorectal cancer xenografts. RESULTS AND CONCLUSION: The portable hybrid camera prototype has been shown to successfully image dual NIR-gamma tracers using both in vitro and in vivo experimental models. With further development, this camera could be used intraoperatively, offering the benefits of gamma imaging at depth in tissues and high resolution surface NIR fluorescence imaging in a single imaging system.

Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Application Or Innovation In Engineering & Management
Far Infrared Photoconductive Detector Based on Multi-Wall Carbon Nanotubes

Far infrared photoconductive detectors based on multi-wall carbon nanotubes (MWCNTs) were fabricated and their characteristics were tested. MWCNTs films deposited on porous silicon (PSi) nanosurface by dip and drop coating techniques. Two types of deposited methods were used; dip coating sand drop –by-drop methods. As well as two types of detector were fabricated one with aluminum mask and the other without, and their figures of merits were studied. The detectors were illuminated by 2.2 and 2.5 Watt from CO2 of 10.6 􀀀m and tested. The surface morphology for the films is studied using AFM and SEM micrographs. The films show homogeneous distributed for CNTs on the PSi layer. The root mean square (r.m.s.) of the films surface roughness in

... Show More
Publication Date
Tue Nov 01 2022
Journal Name
Standards
Observation of a Signal Suppressing Effect in a Binary Mixture of Glycol-Water Contamination in Engine Oil with Fourier-Transform Infrared Spectroscopy

An in-depth experimental study of the matrix effect of antifreeze (ethylene glycol) and water contamination of engine oil through FT-IR spectroscopy. With a comparison of the percent by volume concentration of contaminated fresh 15W-40 engine oil, there appeared to be a noticeable reduction in the O–H stretching signal in the infrared spectrum when ethylene glycol based antifreeze was included as a contaminant. The contaminants of distilled water, a 50/50 mixture of water and commercial ethylene glycol antifreeze, and straight ethylene glycol antifreeze were compared and a signal reduction in the O–H stretch was clearly evident when glycol was present. Doubling the volume of the 50/50 mixture as compared to water alone still res

... Show More
Crossref
View Publication
Publication Date
Thu Sep 01 2016
Journal Name
Radiology Case Reports
Intralobar pulmonary sequestration in elderly woman: a rare case report with emphasis on imaging findings

Scopus (6)
Crossref (10)
Scopus Crossref
View Publication
Publication Date
Sat Jul 01 2023
Journal Name
International Journal Of Computing And Digital Systems
Human Identification Based on SIFT Features of Hand Image

Scopus (1)
Scopus Crossref
View Publication
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Tracked Robot Control with Hand Gesture Based on MediaPipe

Hand gestures are currently considered one of the most accurate ways to communicate in many applications, such as sign language, controlling robots, the virtual world, smart homes, and the field of video games. Several techniques are used to detect and classify hand gestures, for instance using gloves that contain several sensors or depending on computer vision. In this work, computer vision is utilized instead of using gloves to control the robot's movement. That is because gloves need complicated electrical connections that limit user mobility, sensors may be costly to replace, and gloves can spread skin illnesses between users. Based on computer vision, the MediaPipe (MP) method is used. This method is a modern method that is discover

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Thu Apr 28 2022
Journal Name
Iraqi Journal Of Science
Photometric Investigations of Peculiar spiral galaxy NGC 2608 Using Multiband CCD Camera

The structural of peculiar spiral galaxy NGC 2608 have been studied using multiband CCD surface photometry of the observations that have been obtained by the 1.88 m optical telescope of Kottamia Astronomical Observatory (Egypt). We studied the structure and radial brightness distribution of the galaxy. The surface brightness distribution indicate that the center of the galaxy consist of two nucleus. The photometric parameters of its components and the color distribution over the galactic are estimated and stellar populations in different regions of the galaxy are analyzed using color diagram. The distributions of the color indices show that the observed photometric symmetry in the inner part of the galaxy, including the bar, is due to a

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 25 2014
Journal Name
Sensors
Minimal Camera Networks for 3D Image Based Modeling of Cultural Heritage Objects

Scopus (37)
Crossref (28)
Scopus Clarivate Crossref
View Publication
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Science
Automatic Number Extraction from Fixed Imaging Distance

     Developed countries are facing many challenges to convert large areas of existing services to electronic modes, reflecting the current nature of workflow and the equipment utilized for achieving such services. For instance, electricity bill collection still tend to be based on traditional approaches (paper-based and relying on human interaction) making them comparatively time-consuming and prone to human error.

This research aims to recognize numbers in mechanical electricity meters and convert them to digital figures utilizing Optical Character Recognition (OCR) in Matlab. The research utilized the location of red region in color electricity meters image to determine the crop region that contain the meters numbers, then

... Show More
Scopus Crossref
View Publication