Beta-lactam medications are among the commonly used antibiotics that share the presence of a beta-lactam ring in their chemical formation. A modern, rapid, highperformance liquid chromatography technique was advanced and validated according to FDA and EMA rules for the concurrent determination of medications in their pharmaceutical and pure forms This study deals with the determination of beta-lactam drugs )Amoxicillin, Ampicillin Cephalexin, Cefotaxime, Cefoxitin, Cefamandole, Cephalothin, Piperacillin, Penicillin, Oxacillin, Cloxacillin Nafcillin, Carbenicillin, Mezlocillin and Dicloxacillin) which is a RP-HPLC technique with an UV detector using a column NEUCLEODUR C-18 (4.0 mm × 100 mm, 5µm particle size), The heat of the chr
... Show MoreTwo quantitative, environment-friendly and easily monitored assays for Ni (II) and Co (III) ions analysis in different lipstick samples collected from 500-Iraqi dinars stores located in Baghdad were introduced. The study was based on the reaction of nickel (II) ions with dimethylglyoxime (DMG) reagent and the reaction of cobalt (III) ions with 1-nitroso-2-naphthol (NN) reagent to produce colored products. The color change was measured by spectrophotometric method at 565 nm and 430 nm for Ni and Co, respectively, with linear calibration graphs in the concentration range 0.25-100 mg L-1 (Ni) and 0.5-100 mg L-1 (Co) and LOD and LOQ of 0.11 mg L-1 and 0.36 mg L-1 (Ni), and 0.15 mg L-1 an
... Show MoreAn Indirect simple sensitive and applicable spectrofluorometric method has been developed for the determination of Cefotaxime Sodium (CEF), ciprofloxacin Hydrochloride (CIP) and Famotidine (FAM) using reaction system bromate-bromide and acriflavine (AF) as fluorescent dye. The method is based on the oxidation of drugs with known excess bromate-bromide mixture in acidic medium and subsequent determination of unreacted oxidant by quenching fluorescence of AF. Fluorescence intensity of residual AF was measured at 528 nm after excitation at 402 nm. The fluorescence-concentration plots were rectilinear over the ranges 0.1-3.0, 0.05-2.6 and 0.1-3.8 µg ml-1 with lower detection limits of 0.013, 0.018 and 0.021 µg ml-1 an
... Show MoreIn this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.
The Plerion nebula is characterized by its pulsar that fills the center of the supernova remnant with radio and X-ray frequencies. In our galaxy there are nine naked plerionic systems known, of which the Crab Nebula is the best-known example. It has been studied this instance in order to investigate how the pulsar energy affect on the distribution and evolution of the remnant as well as study the pulsar kick velocity and its influence on the remnant. From the obtained results it's found that, the pulsar of the Crab Nebula injects about (2−3)𝑥 1047 erg of energy to the remnant, although this energy is small compared to the supernova explosion energy which is about 1051 erg but still plays a significant role in the distribution and the m
... Show MoreOne of the important differences between multiwavelets and scalar wavelets is that each channel in the filter bank has a vector-valued input and a vector-valued output. A scalar-valued input signal must somehow be converted into a suitable vector-valued signal. This conversion is called preprocessing. Preprocessing is a mapping process which is done by a prefilter. A postfilter just does the opposite.
The most obvious way to get two input rows from a given signal is to repeat the signal. Two rows go into the multifilter bank. This procedure is called “Repeated Row” which introduces oversampling of the data by a factor of 2.
For data compression, where one is trying to find compact transform representations for a
... Show MoreA new Schiff base (HL2) ligand (4‐{2‐[(2‐hydroxy‐benzylidene)‐amino]‐ethyl}‐benzene‐1,2‐diol) has been synthesized by condensing of 4‐(2‐amino‐ethyl)‐benzene‐1,2‐diol and 2‐hydroxy‐benzaldehyde. In turn, its transition metal complexes were prepared, having the following general formulas: Ni(L2)2, Pd(L2)2, and Pt(L2)22Cl. The prepared ligand and its metal complexes Ni(II), Pd(II), and Pt(IV) have been characterized by Fourier transform infrared (FTIR) spectra, proton nuclear magnetic resonance (1H‐NMR