Preferred Language
Articles
/
-Bcvso4BVTCNdQwCD1ao
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 nm and turbidmetric method by using the standard addition method via the use of t-test, at 95% confidence level. In addition to the make use of the advantages of using F-test to predict which of the methods is more precise than other method. The comparison of data explains that long distance chasing photometer (NAG-ADF-300-2) is the choice with excellent extended detection, wide application and more sensitive.

Crossref
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Fixation of Efficient Method for Separation and Analysis of Alkyl Al koxy Silan Compounds by Gas Chromatography
...Show More Authors

       Modification of gas chromatographic technique for the separation and determination of methyl ethoy silane compounds which were synthesized by the addition of absolute ethanol to methyl chlorosilane compounds have been elaborated experimentally.  The addition of absolute dry ethanol to methyl chlorosilane compounds in the presence of a dry stream of nitrogen gas led to sweep out the liberated HCl gas. This method was found to be the suitable method for the preparation of methyl ethoxy silane compounds. The optimum parameter selected after careful and precise studies was between 20 – 30 ml \ min to carrieir gas flow rate, while applied temperatures of detector and injection part were 250 Â

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
Kinetic and Mechanism of Oxidation of Oxalic Acid by Cerium (IV)
...Show More Authors

Kinetic and mechanism studies of the oxidation of oxalic acid by Cerium sulphate have been carried out in acid medium sulphuric acid. The uv- vis. Spectrophotometric technique was used to follow up the reaction and the selected wavelength to be followed was 320 nm. The kinetic study showed that the order of reaction is first order in Ce(IV) and fractional in oxalic acid. The effect of using different concentration of sulphuric acid on the rate of the reaction has been studied a and it was found that the rate decreased with increasing the acid concentration. Classical organic tests was used to identify the product of the oxidation reaction, the product was just bubbles of CO2.

 

View Publication Preview PDF
Publication Date
Sat Sep 23 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Nirite By The Diazotization Coupling With Aniline and 4,6 Dihydroxy-2 Mercaptopyrimidine
...Show More Authors

A direct  spectrophotometric method  has  been  developed  for  the

determination of nitrite  in aqueous  solution.  The method  is based on the  reaction  of  the nitritw  ion with an acidified  anline  solution from diazonium  cation   , which   is   subsequently  coupled   Â·with  4,6   - dihydroxy- 2- mercapto  pyrimidine to from yellow colored  and water

- soluble  intense  azo dye  with maximum  absorption at  416nm  . A

graph  of  absorbance  versus  concentration  shows   that  Bee's

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Modified Simplex - Spectrophotometric Determination of Clonazepam via Charge-Transfer Complexation
...Show More Authors

A simple, sensitive, accurate, and precise spectrophotometric method for the determination of clonazepam (CLNZ) was developed. The method is based on charge transfer reaction between CLNZ and p-Bromanil (p-Br) to form a colored complex. The optimum conditions of complex formation were investigated by (1). Unvariable method, for the optimization of reagent concentration, base concentration, temperature, and time. (2). Multivariable simplex method including the effect of three experimental factors via; reagent concentration, concentration of NaOH and time. The linearity range of CLNZ was (1-30) μg.mL-1 at 378 nm under condition established via simplex method with molar absorptivity (1.9069x104) L.

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Total luminescence (Chemiluminescence & Fluorescence)- FIA Method For The Determination of DL-Histidine
...Show More Authors

Histidine was determined via measurement of total luminescence (i:e creation of chemiluminescence and insitu irradiation of released light to an acceptor fluorophore molecule to  initiate fluorescence from fluorescien molecule in flat – spiral micro cell designed for this measurement . A detailed description of robust linear equation for the range of 0.002 – 0.05 mol.L-1 for a sample size of 70 µL with a correlation coefficient of 0.9879 and a coefficient of determination of 97.59% while for a quadratic model of the same concentration range was 0.9881 correlation coefficient and 97.63% coefficient of determination. Analysis of variance was conducted for both kinds of models . It indicated that their was no significa

... Show More
View Publication Preview PDF
Publication Date
Wed May 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Adsorption of Thymol From Aqueous Solution Using Granulated Surfactant Initiated Modified Bentonite via Packed Column Method
...Show More Authors

    The adsorption study of thymol, was carried out at (25±0.1) °C, using granulated surfactant modified Iraqi Na – montmorillonite clay (initiated modified bentonite); in a down-flow packed column, the modified mineral was characterized by FT-IR spectroscopy.  A linear calibration graph for thymol was obtained, which obey Beer's law in the concentration range of 5-50 mg/L at 274 nm against reagent blank. Single-factor-at-a-time approach; showed that the equilibrium time required for complete adsorption was 45 minute with flow rate (4.0drop/ mint). The adsorption of thymol increased with rising pH of the adsorbate solution, increase of solute uptake when  the initial adsor

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 23 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Hard palate bone density and thickness determination using CT scan and their relationships with body compositions measured by bioelectrical impedance analysis for Iraqi adult sample
...Show More Authors

Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Energy Generation from Static Water Head Developed By Forward Osmosis
...Show More Authors

In this work, the possibility of utilizing osmosis phenomenon to produce energy as a type of the renewable energy using Thin Film Composite Ultra Low Pressure membrane TFC-ULP was studied. Where by forward osmosis water passes through the membrane toward the concentrated brine solution, this will lead to raise the head of the high brine solution. This developed static head may be used to produce energy. The aim of the present work is to study the static head developed and the flux on the high brine water solution side when using forward and reverse osmosis membranes for an initial concentration range from 35-300 g/l for each type of membrane used at room temperature and pressure conditions, and finally calculating the maximum possible po

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Ecological Engineering
Removal of Nitrate from Aqueous Solution by Bio-Calcium from Iraqi Eggshells
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Craniofacial Surgery
Single Session Facial Lipostructure by Using Autologous Fat Mixed With Platelet-Rich Fibrin Injected by Using Facial Autologous Muscular Injection Technique
...Show More Authors
Aim:

This study was designed to evaluate the role of single session autologous facial fat grafting in correcting facial asymmetries after mixing it with platelet-rich fibrin (PRF) and injecting them into rich vascular facial muscular plane.

Materials and Methods:

Fifteen patients (12 females and 3 males) with age ranging from 18 years to 40 years were included in this study and followed up during 6 months, all the patients were treated in the Al-Shaheed Ghazi Al-Hariri for specialized surgeries hospital (Medical City, Baghdad, Iraq).

Auto

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref