Preferred Language
Articles
/
-Bcvso4BVTCNdQwCD1ao
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 nm and turbidmetric method by using the standard addition method via the use of t-test, at 95% confidence level. In addition to the make use of the advantages of using F-test to predict which of the methods is more precise than other method. The comparison of data explains that long distance chasing photometer (NAG-ADF-300-2) is the choice with excellent extended detection, wide application and more sensitive.

Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Applied Spectroscopy
SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF METOCLOPRAMIDE IN PHARMACEUTICAL FORMS
...Show More Authors

A UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b

... Show More
Scopus (8)
Scopus
Publication Date
Sun Apr 29 2012
Journal Name
Journal Of Karbala University
Optimization Quantitative Determination of Cimetidine in Pharmaceutical Preparations via Bromothymol Blue Using Central Composite Design
...Show More Authors

Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Artificial Neural Network and Latent Semantic Analysis for Adverse Drug Reaction Detection
...Show More Authors

Adverse drug reactions (ADR) are important information for verifying the view of the patient on a particular drug. Regular user comments and reviews have been considered during the data collection process to extract ADR mentions, when the user reported a side effect after taking a specific medication. In the literature, most researchers focused on machine learning techniques to detect ADR. These methods train the classification model using annotated medical review data. Yet, there are still many challenging issues that face ADR extraction, especially the accuracy of detection. The main aim of this study is to propose LSA with ANN classifiers for ADR detection. The findings show the effectiveness of utilizing LSA with ANN in extracting AD

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (8)
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Indirect Spectrophotometric Determination of Oxymetazoline Hydrochloride in Pharmaceutical Formulation Using Fluorophotometric Method
...Show More Authors

This research involves an indirect Fluorophotometric method for the determination of microgram amount of oxymetazoline hydrochloride in the concentration range 0.1-5.0 g/ml. The method is based on the oxidation of the drug by cerium sulphate solution which is acidic medium where Ce IV is reduced to Ce III which can be excited at 259 nm to give an emitted light at 377 nm which  is directly proportional to the concentration of Ce III which is equivalent to Ce IV that is needed to oxidize the studied drug. The average recovery of the method is 100.19% and relative standard deviation (RSD) < 0.37% . The method have been successfully applied to the determination of the studied drug in its pure and pharmaceutical preparations and it wa

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Simultaneous Quantitative Determination of Ciprofloxacin and Hydrocortisone by H-Point Standard Addition Method
...Show More Authors

Ciprofloxacin (Cip) and hydrocortisone (Hyd) were simultaneously measured as hydrochloride and sodium succinate, respectively, using the H-point standard addition method (HPSAM). The approach can precisely identify Cip in the presence of Hyd with various analyte-to-interference ratios (5:5, 5:10, 10:5, 10:10) µg.mL-1, in mixed samples containing (1-5µg.ml-1) of Cip, at the wavelengths of (236 and 257) nm. In the same way, Hyd was analyzed in the presence of Cip in different analytes with an interference ratio of (5:5, 5:10, 10:5, 10:10) µg.mL-1, in mixed samples containing (1-5 µg.mL-1) of Hyd, at wavelengths of (266 and 278) nm. The satisfactory results show good reproducibility of the dev

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Univariate and Simplex Optimization for the Spectrophotometric Determination of Cimetidine and Erythromycin ethylsuccinate Drugs Using Bromothymol Blue Via Ion-Pair Formation
...Show More Authors

    The ion-pair formation method has been applied for the spectrophotometric determination of Cimetidine and Erythromycin ethylsuccinate, in bulk samples and in dosage form. The methods are accurate, simple, rapid, inexpensive and sensitive depending on the extraction of the formed ion-pair with brompthymol blue (BTB) as a chromogenic reagent in chloroform, use phthalate buffer of pH 5.5 and 4.0 for Cimetidine and Erythromycin ethylsuccinate respectively.  The formed complexes show absorbance maxima at 427.5 nm and 414.5 nm for Cimetidine and Erythromycin ethylsuccinate respectively against reagent blank. The calibration graphs are linear in the ranges of 0.5-15 µg.mL-1 with detection limit of 0.222 µg.mL-1 for

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Geological Journal
Estimation of Initial Oil in Place for Buzurgan Oil Field by Using Volumetric Method and Reservoir Simulation Method
...Show More Authors

The estimation of the initial oil in place is a crucial topic in the period of exploration, appraisal, and development of the reservoir. In the current work, two conventional methods were used to determine the Initial Oil in Place. These two methods are a volumetric method and a reservoir simulation method. Moreover, each method requires a type of data whereet al the volumetric method depends on geological, core, well log and petrophysical properties data while the reservoir simulation method also needs capillary pressure versus water saturation, fluid production and static pressure data for all active wells at the Mishrif reservoir. The petrophysical properties for the studied reservoir is calculated using neural network technique

... Show More
View Publication
Scopus (6)
Scopus Crossref
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Approximation Solutions for System of Linear Fredhom Integral Equations by Using Decomposition Method
...Show More Authors

In this paper, the Decomposition method was used to find approximation solutions for a system of linear Fredholm integral equations of the second kind. In this method the solution of a functional equations is considered as the sum of an infinite series usually converging to the solution, and Adomian decomposition method for solving linear and nonlinear integral equations. Finally, numerical examples are prepared to illustrate these considerations.

View Publication Preview PDF
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering
Permeability Prediction for Nahr-Umr Reservoir / Subba field by Using FZI Method
...Show More Authors

 The permeability determination in the reservoirs that are anisotropic and heterogeneous is a complicated problem due to the limited number of wells that contain core samples and well test data. This paper presents hydraulic flow units and flow zone indicator for predicting permeability of rock mass from core for Nahr-Umr reservoir/ Subba field. The Permeability measurement is better found in the laboratory work on the cored rock that taken from the formation. Nahr-Umr Formation is the main lower cretaceous sandstone reservoir in southern of Iraq. This formation is made up mainly of sandstone. Nahr-Umr formation was deposited on a gradually rising basin floor. The digenesis of Nahr-Umr sediments is very important du

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Fixation of Efficient Method for Separation and Analysis of Alkyl Al koxy Silan Compounds by Gas Chromatography
...Show More Authors

       Modification of gas chromatographic technique for the separation and determination of methyl ethoy silane compounds which were synthesized by the addition of absolute ethanol to methyl chlorosilane compounds have been elaborated experimentally.  The addition of absolute dry ethanol to methyl chlorosilane compounds in the presence of a dry stream of nitrogen gas led to sweep out the liberated HCl gas. This method was found to be the suitable method for the preparation of methyl ethoxy silane compounds. The optimum parameter selected after careful and precise studies was between 20 – 30 ml \ min to carrieir gas flow rate, while applied temperatures of detector and injection part were 250 Â

... Show More
View Publication Preview PDF