Push-out test of eco-friendly steel-concrete–steel composite sections enhanced by polypropylene fibers: An experimental study and statistical analysis
...Show More Authors

Steel-concrete-steel (SCS) structural element solutions are rising due to their advantages over conventional reinforced concrete in terms of cost and strength. The impact of SCS sections with various core materials on the structural performance of composites has not yet been fully explored experimentally, and in this work, both slag and polypropylene fibers were incorporated in producing eco-friendly steel-concrete-steel composite sections. This study examined the ductility, ultimate strength, failure modes, and energy absorption capacities of steel-concrete-steel filled with eco-friendly concrete, enhanced by polypropylene fiber (PPF) to understand its impact on modern structural projects. Eco-friendly concrete was produced by the partial replacement of cement with waste material such as ground granulated blast-furnace slag (GGBS) to reduce carbon dioxide emitted as one of the by-products of cement which harms the environment. A constant rate of cement replacement with GGBS was used. Polypropylene fibers were used as a fill material in the structural elements to enhance the performance. Seven specimens of SCS were analyzed for their mechanical properties using push-out monotonic loading. The control specimen was constructed with a conventional concrete core, even as testing specimens had different amounts of polypropylene fiber added to the core. The current investigation indicates that the impact of polypropylene fiber (PPF) material filling concrete on SCS performance is somewhat smaller than that of ordinary concrete (less than 10 percent). Applying PPF to concrete can increase its tensile strength, slow the spread of cracks, and strengthen the material overall. The compressive strengths of the samples were affected by the proportion of PPF, with the strength increasing from 47.6 MPa to 56.43 MPa as the PPF levels increased from 0 to 2 percent. Compared to the control sample, the PPF SCS specimens had an increased energy absorption. On the other hand, in comparison to PPF SCS specimens, the ductility level of the control sample was smaller.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Time Dependent Behavior of Engineered Cementitious Composite Concrete Produced from Portland Limestone Cement
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 20 2021
Journal Name
Earth And Environmental Science
Time Dependent Behavior of Engineered Cementitious Composite Concrete Produced from Portland Limestone Cement
...Show More Authors

Conventional concretes are nearly unbendable, and just 0.1 percent of strain potential makes them incredibly brittle and stiff. This absence of bendability is a significant cause of strain failure and has been a guiding force in the production of an elegant substance, bendable concrete, also known as engineered cement composites, abbreviated as ECC. This type of concrete is capable of displaying dramatically increased flexibility. ECC is reinforced with micromechanical polymer fibers. ECC usually uses a 2 percent volume of small, disconnected fibers. Thus, bendable concrete deforms but without breaking any further than conventional concrete. This research aims to involve this type of concrete, bendable concrete, that will give solut

... Show More
Publication Date
Tue Nov 15 2022
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
A-mechanical properties of engineered cementitious composite concrete produced from Portland limestone cement
...Show More Authors

Conventional concretes are almost unbending, and even a small amount of strain potential leaves them brittle. This lack of bendability is a major source of strain loss, and it has been the main goal behind the development of bendable concrete, often known with engineered ce ment composites, or ECC. This form of concrete has a lot more flexibility than regular concrete. Micromechanical polymer fibers are used to strengthen ECC. In most cases, ECC uses a 2% amount of thin, separated fibers. As a result, bendable concrete deforms but unlike traditional concrete, it does not crack. This study aims to include this kind of concrete, bendable concrete, which can be used to solve concrete problems. Karasta (CK) and Tasluja (CT) Portland Lime

... Show More
Publication Date
Tue Mar 01 2022
Journal Name
Results In Engineering
Predictive model for stress at ultimate in internally unbonded steel tendons based on genetic expression programming
...Show More Authors

View Publication
Crossref (13)
Crossref
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
Verification and Parametric Analysis of Shear Behavior of Reinforced Concrete Beams using Non-linear Finite Element Analysis
...Show More Authors

Many researchers have tackled the shear behavior of Reinforced Concrete (RC) beams by using different kinds of strengthening in the shear regions and steel fibers. In the current paper, the effect of multiple parameters, such as using one percentage of Steel Fibers (SF) with and without stirrups, without stirrups and steel fibers, on the shear behavior of RC beams, has been studied and compared by using Finite Element analysis (FE). Three-dimensional (3D) models of (RC) beams are developed and analyzed using ABAQUS commercial software. The models were validated by comparing their results with the experimental test. The total number of beams that were modeled for validation purposes was four. Extensive pa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 15 2021
Journal Name
Plant Archives
ISOLATION AND IDENTIFICATION OF GBS BACTERIA FROM MASTITIS BY CAMP TEST AND LANCEFIELD’S SEROLOGICAL GROUPING
...Show More Authors

Mastitis is an udder tissue inflammation which has infected various species of animals. It happens through several types of pathogenic bacteria, particularly Streptococcus agalactiae. GBS is a leading cause of cow mastitis. In our sample, 9.52% of Streptococcus agalactiae were isolated which were collected from bovine mastic milk and identified by biochemical tests such as catalase, oxidase, Production of indole, fermentation of sugar, an examination of antibiotic sensitivity, CAMP test and group kits of Lancefield. The results showed that all Streptococcus agalactiae isolate was diagnosed by CAMP test by the appearance of the arrowhead in blood agar and by the appearance of visible agglutination on a card in the serological grouping kit of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Results In Engineering
Implementation of a control and monitoring system for a cathodic protection cell to mitigate localized corrosion in fixed and mobile steel structures
...Show More Authors

The current study introduces a novel technique to handle electrochemical localized corrosion in certain limited regions rather than applying comprehensive cathodic protection (CP) treatment. An impressed current cathodic protection cell (ICCPC) was fabricated and firmly installed on the middle of a steel structure surface to deter localized corrosion in fixed or mobile steel structures. The designed ICCPC comprises three essential parts: an anode, a cathode, and an artificial electrolyte. The latter was developed to mimic the function of the natural electrolyte in CP. A proportional-integrated-derivative (PID) controller was designed to stabilize this potential below the ICCPC at a cathodic potential of −850 mV, which is crucial for prote

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jun 30 2024
Journal Name
Science And Technology Indonesia
Evaluating the Biocompatibility of Maxillofacial Silicone Enhanced by Hexagonal Boron Nitride Particles
...Show More Authors

This study aims to evaluate the biocompatibility of a novel filler material intended to improve the longevity of polymer systems used in prosthetics in respect of cytotoxicity and skin irritation. RTV50F silicone elastomer incorporated with various percentages of hexagonal boron nitride (H-BN) (0.1, 0.3, 0.5, 0.7, and 1 wt%) have been tested. Silicone without H-BN was utilized as the control for comparison. The in vitro cytotoxicity test includes specimens (n=18) with 10 mm in diameter and 2 mm in thickness applied directly to the normal human fibroblast cell line (NHF) and incubated for 72 hours, then 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay was used to determine the cell viability. The skin irritati

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Inhibition Effect of Peach Juice on Corrosion of Low Carbon Steel in Hydrochloric Acid at Different Temperatures
...Show More Authors

The corrosion inhibition of low carbon steel in1N HCl solution in the presence of peach juice at temperature (30,40,50,and 60)°C at concentration ( 5, 10, 20, 30, 40and 50 cm3/L)were studied using weight loss and polarization techniques. Results show that the inhibition efficiency was increased with the increase of inhibitor concentration and increased with the increase of temperature up to 50ºC ,above 50ºC (i.e. at 60 ºC) the values of efficiency decreases. Activation parameters of the corrosion process such as activation energies, Ea, activation enthalpies, ΔH, and activation entropies, ΔS, were calculated. The adsorption of inhibitor follows Langmuir isotherm. Maximum inhibition efficiency obtained was a bout 91% at 50ºC in the

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Anodic Polarization of Mild Steel in Saturated C a(OH)2 Contaminated with NaCl in Presence of NaNO2
...Show More Authors

The corrosion  behavior  of mild sleet  in saturated  aerated  and de-aerated  Ca(OH)2 solution  was  investigated  using electrochemical measurements. The work was carried out with small coupons immersed in solutions containing different quantities of NaCl in presence of various NaN02 concentrations as corrosion inhibitors. It has been found thal:(1 ) In presence  of NaCl,  the time required  to reach O2  evolution potential  in de-aerated  Ca(OH)2 polarized  at  10μA/cm 2 is function of inhibitor concentration and it becomes lass as NaN02 increases compared with zero presence indicating the effectiveness of N

... Show More
View Publication Preview PDF