Improved oral bioavailability of lipophilic substances can be achieved using self-emulsifying drug delivery systems. However, because the properties of self-emulsifying are greatly influenced by surfactant amount and type, type of oil used, droplet size, charge, cosolvents, and physiological variables, the synthesis of self-emulsifying is highly complex; consequently, only a small number of excipient self-emulsifying formulations has been developed so far for clinical use. This study reports a highly effective procedure for developing self-emulsifying formulations using a novel approach based on the hydrophilic-lipophilic difference theory. Microemulsion characteristics, such as the constituents and amounts of oil and surfactant electrolyte concentration and temperature, were optimized to produce high-quality self-emulsifying drug delivery systems. Furthermore, in vitro lipolysis and in vivo bioavailability studies of fenofibrate, a highly lipophilic oral drug, loaded self-emulsifying dosage form were conducted. The self-emulsifying drug delivery system used in this study comprised soybean oil, water with a specific salinity, sodium dioctyl sulphosuccinate as a surfactant, and orlistat as a lipase inhibitor. The hydrophilic-lipophilic difference-based approach involved fewer experiments and allowed for the development of an efficient self-emulsifying dosage form with a relatively low surfactant concentration when compared to previous works. The salinity and equivalent alkane carbon number were optimized, with the proper selection of the type and amount of surfactant, to obtain a bicontinuous microemulsion (Winsor type III) that can be fully diluted with water. In vitro lipolysis was investigated in fasting and feeding settings, which showed a significant dosage form digestion by lipase enzyme; orlistat was successfully used to overcome dosage digestion and drug precipitation problem. In vivo experiments in rats involved oral gavage with a self-emulsifying dosage form containing fenofibrate (20 mg/kg). The pharmacokinetic profile of fenofibric acid showed remarkable enhancement in the bioavailability (F-95%). These findings demonstrate that the hydrophilic-lipophilic difference approach is a practical, scalable, and easy technique for self-emulsifying drug delivery system formulation development. Keywords: HLD theory, fenofibrate, SEDDS, lipolysis
Objective: The evaluation of serum osteocalcin (OSN) for Iraqi infertile patients to see the effect of osteocalcin insufficiency, which may lead to a decreased level of testosterone production in males that may cause infertility. Methods: Forty two newly diagnosed infertile males age range (24–47) years and thirty two apparently healthy males as controls age range (25–58) years. Serum levels of testosterone (TEST), stimulating follicle hormone (FSH) and luteinizing hormone (LH), prolactin (PROL), osteocalcin OSN, and fasting blood sugar (FBS) were performed in both patients and controls. Estimation of serum OSN by Immulite1000 auto-analyzer, TEST, FSH, LH, PROL, and FBS by Immulite2000 auto-analyzer. Results: Infertile patients
... Show MoreThis study deals with the role of compensation system in improving the quality of educational services (University of Halabja as a Model) also our problem was the following question ; What is the role of compensation system in its different dimensions in improving the quality of educational services? And what is the relationship and impact of using the dimensions of the compensation system to improve the quality of educational services? The hypothesis of the research included the correlation and the impacts between the compensation system and its combined variables in the quality of educational services. This was proved through a field study and the distribution of questionn
... Show MoreThe Environmental Data Acquisition Telemetry System is a versatile, flexible and economical means to accumulate data from multiple sensors at remote locations over an extended period of time; the data is normally transferred to the final destination and saved for further analysis.
This paper introduces the design and implementation of a simplified, economical and practical telemetry system to collect and transfer the environmental parameters (humidity, temperature, pressure etc.) from a remote location (Rural Area) to the processing and displaying unit.
To get a flexible and practical system, three data transfer methods (three systems) were proposed (including the design and implementation) for rural area services, the fi
... Show MoreThis research is devoted to investigating the thermal buckling analysis behaviour of laminated composite plates subjected to uniform and non-uniform temperature fields by applying an analytical model based on a refined plate theory (RPT) with five unknown independent variables. The theory accounts for the parabolic distribution of the transverse shear strains through the plate thickness and satisfies the zero-traction boundary condition on the surface without using shear correction factors; hence a shear correction factor is not required. The governing differential equations and associated boundary conditions are derived by using the virtual work principle and solved via Navier-type analytical procedure to obtain critica
... Show MoreA QR code is a type of barcode that can hold more information than the familiar kind scanned at checkouts around the world. The “QR” stands for “Quick Response”, a reference to the speed at which the large amounts of information they contain can be decoded by scanners. They are being widely used for advertising campaigns, linking to company websites, contest sign-up pages and online menus. In this paper, we propose an efficient module to extract QR code from background and solve problem of rotation in case of inaccurate image taken from mobile camera.
Recently, there has been an increasing advancement in the communications technology, and due to the increment in using the cellphone applications in the diverse aspects of life, it became possible to automate home appliances, which is the desired goal from residences worldwide, since that provides lots of comfort by knowing that their appliances are working in their highest effi ciency whenever it is required without their knowledge, and it also allows them to control the devices when they are away from home, including turning them on or off whenever required. The design and implementation of this system is carried out by using the Global System of Mobile communications (GSM) technique to control the home appliances – In this work, an ele
... Show MorePsoriasis is a complex autoimmune disorder characterized by skin inflammation with keratinocyte proliferation, and 85% of cases present as plaque-type psoriasis. Biologics such as ustekinumab (UST) are highly successful therapies for psoriasis. To achieve maximum clinical efficacy while minimizing undesirable effects, therapeutic drug monitoring (TDM) for biologics has emerged. This study aims to measure the UST trough level (TL) and anti-drug antibodies (ADAs) and to evaluate clinical response in Iraqi patients with moderate-to-severe psoriasis in order to make appropriate recommendations for modifying therapy. This cross-sectional study enrolled 75 patients, divided into two groups: Group 1, patients who achieved the UST target TL (≥0.6
... Show MoreThis paper deals with a Twin Rotor Aerodynamic System (TRAS). It is a Multi-Input Multi-Output (MIMO) system with high crosscoupling between its two channels. It proposes a hybrid design procedure that combines frequency response and root locus approaches. The proposed controller is designated as PID-Lead Compensator (PIDLC); the PID controller was designed in previous work using frequency response design specifications, while the lead compensator is proposed in this paper and is designed using the root locus method. A general explicit formula for angle computations in any of the four quadrants is also given. The lead compensator is designed by shifting the dominant closed-loop poles slightly to the left in the s-plane. This has the effect
... Show More