Preferred Language
Articles
/
zxe7bo8BVTCNdQwC2ncK
Apexification and Periapical Healing of Immature Teeth Using Mineral Trioxide Aggregate
...Show More Authors

Crossref
View Publication
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Science And Research (ij
Simulation of Chlorine Decay in Al-Gukook WaterDistribution Networks Using EPANET
...Show More Authors

The approach of the research is to simulate residual chlorine decay through potable water distribution networks of Gukookcity. EPANET software was used for estimating and predicting chlorine concentration at different water network points . Data requiredas program inputs (pipe properties) were taken from the Baghdad Municipality, factors that affect residual chlorine concentrationincluding (pH ,Temperature, pressure ,flow rate) were measured .Twenty five samples were tested from November 2016 to July 2017.The residual chlorine values varied between ( 0.2-2mg/L) , and pH values varied between (7.6 -8.2) and the pressure was very weak inthis region. Statistical analyses were used to evaluated errors. The calculated concentrations by the calib

... Show More
Publication Date
Sun Jan 01 2012
Journal Name
International Journal Of Astronomy And Astrophysics
Study the Radial Expansion of SN 1987A Using Counting Pixels Method
...Show More Authors

View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Stabilization of Al-Rustamiya Waste Water Treatment Plant Sludge Using Lime
...Show More Authors

A study was performed to evaluate heavy metals removal from sewage sludge using lime. The processes of stabilization using alkaline chemicals operating on a simple principle of raising pH to 12 or higher, with sufficient mixing and suitable contact time to ensure that immobilization can reduce heavy metals. A 0.157 m3 tank was designed to treat Al-Rustemeyia wastewater treatment plant sludge. Characteristics of raw sludge were examined through two parameters: pH and heavy metal analysis. Different lime doses of (0- 25) g CaO/100 g sludge were mixed manually with raw sludge in a rotating drum. The samples were analyzed two hours after mixing. pH and heavy metals results were compared with EPA and National Iraqi Stand

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reduction of Sulfur Compounds from Petroleum Fraction Using Oxidation-Adsorption Technique
...Show More Authors

Oxidation of sulfur compounds in fuel followed by an adsorption process were studied using two modes of operation, batch mode and continuous mode (fixed bed). In batch experiment oxidation process of kerosene with sulfur content 2360 ppm was achieved to study the effect of amount of hydrogen peroxide(2.5, 4, 6 and 10) ml at different temperature(40, 60 and 70)°C. Also the effect of amount acetic acid was studied  at the optimal conditions of the oxidation step(4ml H2O2 and 60 °C).Besides, the role of acetic acid different temperatures(40, 60, 70) °C and 4ml H2O2, effect of reaction time(5, 30, 60, 120, 300) minutes at temperatures(40,60) °C, 4ml H2O2 and 1 mlHAC)&

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Elimination of Congo Red Dyes From Aqueous Solution Using Eichhornia Crassipes
...Show More Authors

   Water hyacinth (Eichhornia crassipes) is a free-floating plant, growing plentifully in the tropical water bodies. It is being speculated that the large biomass can be used in wastewater treatment, heavy steel and dye remediation, as a substrate for bioethanol and biogas production, electrical energy generation, industrial uses, human food and antioxidants, medicines, feed, agriculture, and sustainable improvement. In this work, the adsorption of Congo Red (CR) from aqueous solution onto EC biomass was investigated through a series of batch experiments. The effects of operating parameters such as pH (3-9), dosage (0.1-0.9 g. /100 ml), agitated velocity (100-300), size particle (88-353μm), temperature (10-50˚C), initial dye

... Show More
View Publication Preview PDF
Crossref (14)
Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Heavy Metals from Industrial Wastewater by Using RO Membrane
...Show More Authors

Industrial wastewater containing nickel, lead, and copper can be produced by many industries. The reverse osmosis (RO) membrane technologies are very efficient for the treatment of industrial wastewater containing nickel, lead, and copper ions to reduce water consumption and preserving the environment. Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50 to 200 ppm), pressures (1 to 4 bar), temperatures (10 to 40 oC), pH (2 to 5.5), and flow rates (10 to 40 L/hr), were prepared and subjected to treatment by RO system in the laboratory. The results showed that high removal efficiency of the heavy metals could be achieved by RO process (98.5%, 97.5% and 96% for Ni(II),

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Characterization Performance of Monocrystalline Silicon Photovoltaic Module Using Experimentally Measured Data
...Show More Authors

Solar photovoltaic (PV) system has emerged as one of the most promising technology to generate clean energy. In this work, the performance of monocrystalline silicon photovoltaic module is studied through observing the effect of necessary parameters: solar irradiation and ambient temperature. The single diode model with series resistors is selected to find the characterization of current-voltage (I-V) and power-voltage (P-V) curves by determining the values of five parameters ( ). This model shows a high accuracy in modeling the solar PV module under various weather conditions. The modeling is simulated via using MATLAB/Simulink software. The performance of the selected solar PV module is tested experimentally for differ

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Feb 06 2024
Journal Name
Research Square
Bioremediation of Cellulosic Wastes by Using Orthodillo chiltoni (Vandel, 1973), Isopoda
...Show More Authors

Terrestrial isopods play an important role in the biodegradation of many wastes which gives agreat importance in the nutrient cycles and ecosystem services , therefore this paper aims to use species Orthodillo chiltoni (Vandel, 1973) as a model organism in bioremediation of urban environment with municipal wastes, agricultural fields, parks and markets wastes. Samples of these wastes included potato peels, orange fruit leaves, thyme plant and sawdust,cardboard residues , the experiments were carried out in laboratory condition similar to the living environment of this species in terms of temperature, humidity and intensity lighting. The applied results have shown that

... Show More
View Publication
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Assessment of Left Ventricular Function in Body builders using conventional echocardiography
...Show More Authors

Background: Powerlifters and bodybuilders use anabolic androgenic steroids (AAS) especially – as many as 55 percent of elite powerlifters admitted using these agents. In contrast to numerous documented toxic and hormonal effects of AAS their impact on the structure and function of the left ventricular (LV) was not yet fully understood.

Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Implementation of a Proposed Load-Shedding System Using Altera DE2 FPGA
...Show More Authors

A load-shedding controller suitable for small to medium size loads is designed and implemented based on preprogrammed priorities and power consumption for individual loads. The main controller decides if a particular load can be switched ON or not according to the amount of available power generation, load consumption and loads priorities. When themaximum allowed power consumption is reached and the user want to deliver power to additional load, the controller will decide if this particular load should be denied receiving power if its priority is low. Otherwise, it can be granted to receive power if its priority is high and in this case lower priority loads are automatically switched OFF in order not to overload the power generation. The

... Show More
View Publication Preview PDF