In recent years, there is more interest in water sources availability, including groundwater due to an increase in demand for water because of the increasing population in the world, and the water recedes due to climate change also. Therefore, the study of groundwater has required more attention. The aim of the present study is to establish a MODFLOW model in the groundwater modeling system software to simulate the movement of groundwater in the Turssaq alluvial fan which is located in the Qazaniyah city, east of Diyala Governorate. The solid model was used to define the aquifer in the study area. Using the GIS software, mapping and preparing the data needed to create a conceptual model were carried out. The data of the
... Show MoreThe shortage in surface water quantities led to a shift in dependence on the groundwater as an alternative water source in southern parts of Iraq. The groundwater is decreasing in quantity and water quality is degrading due to different factors. Therefore, it is important to assess the groundwater quality of the Missan Governorate of the country by analyzing the physicochemical parameters and distinguishing the probable sources of contaminants in the area. The present study used water quality diagrams and statistical methods such as factor analysis and agglomerative cluster analysis to determine the sources of chemical ions in the forty-four groundwater samples collected from wells in the study area. In addition, the Water Quality Index (WQ
... Show MoreThe uniform flow distrbiution in the multi-outlets pipe highly depends on the several parameters act togather. Therefor, there is no general method to achieve this goal. The goal of this study is to investigate the proposed approach that can provide significant relief of the maldistribution. The method is based on re-circulating portion of flow from the end of the header to reduce pressure at this region . The physical model consists of main manifold with uniform longitudinal section having diameter of 152.4 mm (6 in), five laterals with diameter of 76.2 mm (3 in), and spacing of 300 mm. At first, The experiment is carried out with conventional manifold, which is a closed-end. Then, small amount of water is allowed
... Show MoreIn this paper the specific activity of 238U, 232Th and 40K
radionuclides were determined by sodium iodide enhanced by
thallium NaI(Tl) detector and assessment the annual effective dose
in samples of powder milk from different companies such as
Almunaish, Seven Caw, Molty and Altunsa for adult available in
Baghdad markets. The specific activity of 40K has the greater value in
all the samples which is in the range of allowed levels globally that
suggested by UNSCEAR. The mean value of annual effective doses
were 0.121, 0.314775 and 0.305 mSv/y for 238U, 232Th and 40K
respectively.
In this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average valu
Many important archaeological sites in Iraq still need to be preserved. Some of these sites were subjected to destruction and negligence. So, exploring these sites represents a priority for its protection. A 2D Electrical Resistivity Imaging (ERI) as a non-invasive geophysical survey method was implemented at a part of the Borsippa archaeological site near Babylon to search for the subsurface archaeological artefacts/structures. Electrical resistivity measurements were carried out using a Dipole-Dipole array. Steps were taken to process and filter using Horizontal profiles, forward modelling, and 2D inverse models to analyze the resistivity measurements. The ERI inversion results show that the superficial conductive zone produced va
... Show MoreAntibiotic resistance is a problem of deep scientific concern both in hospital and community settings. Rapid detection in clinical laboratories is essential for the judicious recognition of antimicrobial resistant organisms. So, the growth of Uropathgenic Escherichia coli (UPEC) isolates with Multidrug-resistant (MDR) and Extensively Drug-resistant (XDR) profiles that thwart therapy for (UTIs) has been detected and has straight squeezed costs and extended hospital stays. This study aims to detect MDR- and XDR-UPEC isolates. Out of 42 UPEC clinical isolates were composed from UTI patients. The bacterial strains were recognized by standard laboratory protocols. Susceptibility to antibiotic was measured by the standard disk diffusi
... Show MoreIn the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.
Groundwater quality investigation has been carried out in the western part of Iraq (west longitude '40°40). The physicochemical analyses of 64 groundwater samples collected from seven aquifers were used in the determination of groundwater characterization and assessment. The concept of spatial hydrochemical bi-model was prepared for quantitative and qualitative interpretation. Hydrogeochemical data referred that the groundwater is of meteoric origin and has processes responsible for observed brackishness. The geochemical facies of the groundwater reveal that none of the anions and cations pairs exceed 50% and there are practically mixtures of multi-water types (such as Ca–Mg–Cl–HCO3 and Na+K–SO4–Cl water type) as do
... Show More