Preferred Language
Articles
/
yxZGpYsBVTCNdQwCgtWK
User authentication system based specified brain waves
...Show More Authors

A security system can be defined as a method of providing a form of protection to any type of data. A sequential process must be performed in most of the security systems in order to achieve good protection. Authentication can be defined as a part of such sequential processes, which is utilized in order to verify the user permission to entree and utilize the system. There are several kinds of methods utilized, including knowledge, and biometric features. The electroencephalograph (EEG) signal is one of the most widely signal used in the bioinformatics field. EEG has five major wave patterns, which are Delta, Theta, Alpha, Beta and Gamma. Every wave has five features which are amplitude, wavelength, period, speed and frequency. The linear feedback shift-register(LFSR) is a widely used tool for generating cryptographic sequences like Galois, Fibonacci. In this paper authentication system is designed using the specified brain waves which are Gamma and Betta wave’s features in order to generate the user authenticated sequence using Galois LFSRs.

Scopus
Publication Date
Wed May 15 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Preparation and Optimization of Olanzapine as Transdermal Nanoparticles Delivery System
...Show More Authors

Background: The treatment of schizophrenia typically involves the use of olanzapine (OLZ), a typical antipsychotic drug that has poor oral bioavailability due to its low solubility and first-pass effect.  Objective: To prepare and optimize OLZ as nanoparticles for transdermal delivery to avoid problems with oral administration. Methods: The nanoprecipitation technique was applied for the preparation of eight OLZ nanoparticles by using different polymers with various ratios. Nanoparticles were evaluated using different methods, including particle size, polydispersity index (PDI), entrapment efficiency (EE%), zeta potential and an in vitro release study. The morphology was evaluated by a field emission scanning electron microscope (F

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Design and Implementation of a Contactless Smart House Network System
...Show More Authors

The Internet of Things (IoT) technology is every object around us and it is used to connect these objects to the Internet to verify Machine to Machine (M2M) communication. The smart house system is the most important application of IoT technology; it is increase the quality of life and decrease the efforts. There were many problems that faced the existing smart house networking systems, including the high cost of implementation and upgrading, high power consumption, and supported limited features. Therefore, this paper presents the design and implementation of smart house network system (SHNS) using Raspberry Pi and Arduino platforms as network infrastructure with ZigBee technology as wireless communication. SHNS consists of two mai

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
International Journal Of Chem Tech Research
theoretical study to calculate some parameters of ion optical system
...Show More Authors

Preview PDF
Publication Date
Fri Jan 01 2010
Journal Name
Int. J. Adv. Comp. Techn.
Adding PC Connectivity to the MTS-88 Microcomputer Teaching System
...Show More Authors

The MTS-88. c trainer is a training system targeting students in the microprocessors course. It has a built in single-line assembler allowing the users to enter programs in assembly. It has the problem that long programs cannot be traced and tested efficiently. A simple error may cause all the code to be erased and the system to stop responding. Also, this system lacks the ability to be connected to the PC. The aim of this work is to modify the system to make it possible to be connected to the PC through the parallel port. This gives the capability to download long programs to the system after being developed in the PC. The 8255 Programmable Peripheral Interface available in the teaching system is interfaced to the parallel port and used as

... Show More
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
design Electronic cost accounting system for the Iraqi Airways Company
...Show More Authors

The research Was based to on a real problem and realistically of represented by that  Iraqi Airways company does not have the electronic cost accounting system and therefore  be the process of  the pricing various services provided by a company sample research respecting  air transport and air cargo and aviation fuel and services and catering are not properly especially in the presence of new data from the new companies entering competition in Iraqi aviation industry and therefore does not provide price flexibility in order to compete in getting market share, And then research this problem addressed through design an electronic cost Accounting system covers all the costs incurred by the compan

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat May 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of a new orthodontic bonding system (Beauty Ortho Bond)
...Show More Authors

Background: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyz

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
International Journal Of Science And Research
Blood Supply of Female Reproductive System of Tytoalba (Barn Owl)
...Show More Authors

Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Automatic operation of the optical system in the theatrical show
...Show More Authors

Theatrical techniques took upon themselves the responsibility of building and organizing the theatrical form for the various forms of performances, and it was the important tool that the show makers could rely on in carrying out the various works at the audio-visual level, and lighting is one of the most important elements of the visual formation of the image in the show, as it is related to the visual process and what it can achieve in operations The contrast that constitutes the aesthetic and intellectual values of the theatrical show, especially since the process of adjusting the element of time and the timings for receiving or delivering, moving, and the movement of the actor is what can determine the rhythm of the scene, which in it

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 03 2016
Journal Name
Technology Reports Of Kansai University
Some statistical results for solution type of the Inequalities system
...Show More Authors

Publication Date
Tue May 03 2022
Journal Name
Iraqi Journal Of Science
Study of Some Characteristics in Dielectric Barrier Discharge (DBD) System
...Show More Authors

In this present paper, an experimental study of some plasma characteristics in dielectric barrier discharge (DBD) system using several variables, such as different frequencies and using two different electrodes metals(aluminium (Al) and copper (Cu)), is represented. The discharge plasma was produced by an AC power supply source of 6 and 7 kHz frequencies for the nitrogen gas spectrum and for two different electrodes metals(Al and Cu). Optical emission spectrometer was used to study plasma properties (such as electron temperature ( ), electron number density ( ), Debye length ( ), and plasma frequency ( )). In addition, images were analysed for the plasma emission intensity at atmospheric air pressure.