Perimenopausal bleeding, is a very common problem, which is an alarming symptom for both; women and their doctors because of the rising fears of cellular changes or tumor of endometrium. In our study we tried to prove that collecting endometrial samples using the outpatient method of Pipelle is as effective as collecting the endometrial samples in the traditional method of Dilation and Curettage (DandC) in operation theatre which necessitates general anesthesia. Ninety four patients more than 40 years old were included in the study, all of them were complaining of abnormal uterine bleeding (pregnant ladies and ladies using hormonal contraception were excluded from the study) and endometrial samples were collected first in outpatient clinic using the Pipelle and labelled as A samples and secondly in the theatre under general anesthesia by dilatation and curettage and labelled as B samples, all samples were sent for histopathology without informing the pathologist about the method of sample collection and patients past medical history. Then, the reports of histopathological examination were compared between Pipelle and DandC samples (group A and group B). From the results we can conclude that samples of endometrium using Pipelle could replace the traditional method of DandC, with high specificity and sensitivity in detecting endometrial carcinoma and endometrial hyperplasia.
Background: To find an operation that can be effectively carried out in both adults and children, equally applicable in the elective as well as in the emergency situation and for the good – risk as well as the poor – risk patients. Done by expert and junior surgeons in a short time.
Patients and Methods: Twenty patients with portal hypertension and bleeding varices aged 9-45 years were treated with shunting procedures (group 1, n=10), or a modified Sugiura operation (group 2, n=10) in accordance with the following therapeutic protocol: after resuscitation and diagnostic endoscopy, an emergency modified Sugiura operation was carried out if bleeding could not be controlled over 24 hours. When blee
The dipstick test was evaluated for sero-diagnosis of visceral leishmaniasis. We compared two types of dipstick (rKE16, rK39) tests . The sensitivity of both tests were determined using sera from fifty-two children suspected of having visceral leishmaniasis and thirty healthy children as a control group collected from Central Teaching Hospital of Pediatric in Baghdad. Fifty (96.15%) cases were confirmed to have infection by rKE16 dipstick test while, fourty-six (88.46%) cases were positive by rK39 dipstick test. Non of the sample taken from healthy control showed reactivity in any of these tests. The study indicated that rKE16 test had better sensitivity than rK39 in the diagnosis of VL(100%) ,(92 %) respectively.
Background: Although radiological diagnostic studies (RDS) are an important and acceptable part of medical practice, it is not without hazards. It is associated with increased risk of cancer. Unfortunately the typical and safe dose of each radiological examination is not known. Most of our knowledge of cancer risk comes from studies of survivors of those exposed to whole body radiation from atomic bomb in Hiroshima & Nagasaki, jobs associated with radiation exposure, Chernobyl survivors & patients treated with radiation therapy for cancer and other diseases.
Objectives To estimate radiation dose received by patients from diagnostic radiological examinations and lifetime
... Show MoreA total of 41 patients with gastro duodenal symptoms (show signs of inflammation with or without duodenal ulcer) . 21 males (51.2%) and 20 female (48.8%) with an average age 0f (20 – 80) years old under going gastrointestinal endoscopy at Baghdad teaching hospital in internal disease clinical laboratory , between (February – June) 2009 . Biopsies specimen of antrum , gastric fundus ,& duodenal bulb were examined by the following methods (rapid urease test , Giemsa stain section to detect bacteria , & Haematoxilin and Eosin stained section for pathological study which are considered the gold standard methods , sera or plasma from these patients were tested by immunochromotography (ICM),serological m
... Show MoreBackground: Few Studies had been done on the role of histopathology in the medico-legal diagnosis of Electrocution even abroad.
Aim of the study: To determine the main histopathlogical features in cases of electrocution especially at the entry site of the electrical current which help in the diagnosis of those cases.
Methods: A full medico-legal autopsy had been done on 64 cadavers of persons died as a result of electrocution chosen randomly out of a total number of 144 cases of electrocution
during the year 2005 in the medico-legal institute of Baghdad including histopathological examination by ordinary method of different specimens from those cadavers at histopathology
department of the mentioned institu
Among the undesirable effects of soil compaction is a measurable reduction in plant growth and crop yield. The prevailing belief is that compacted tillage pans are caused by repetitive farming practices, heavy tractors, tillage tools, and field traffic. This experiment was conducted to determine and map the hardpan layers across an agricultural field through advanced technologies of precision agriculture. These valuable techniques such as data logger, yield map, and data analysis of performance indicators were linked with accurate global positioning systems (GPS) datasets. These important technologies provided the farmers and helped them to identify and manage areas of the fields with higher compacted layers. Three ground speeds 4.3
... Show MoreScheduling problems have been treated as single criterion problems until recently. Many of these problems are computationally hard to solve three as single criterion problems. However, there is a need to consider multiple criteria in a real life scheduling problem in general. In this paper, we study the problem of scheduling jobs on a single machine to minimize total tardiness subject to maximum earliness or tardiness for each job. And we give algorithm (ETST) to solve the first problem (p1) and algorithm (TEST) to solve the second problem (p2) to find an efficient solution.