Carbon Fiber-Reinforced Polymer (CFRP) bars have several advantages over traditional steel reinforcement, including low density, erosion resistance, and higher tensile strength. The ACI 440.11-22 code permits CFRP as reinforcement; however, there are limited experimental studies on its application in Reinforced Concrete (RC) columns under combined loads. This study utilized theoretical analysis and Finite Element Analysis (FEA) to investigate 25 square slender concrete columns (kL/r = 17) affected by concentric and eccentric loads, examining variables, like CFRP bar contribution, eccentricity-to-depth ratio, and reinforcement arrangement. The results demonstrated CFRP's effectiveness in these columns, with failure modes varying from brittle compression-controlled under low eccentricities to tension-controlled under high eccentricities. The FEA results indicated that the CFRP columns exhibited higher second-order moments than the steel columns due to CFRP's lower elastic modulus, these results were compatible with the experimental results. Moreover; the (P-M) interaction diagram of CFRP reinforced column does not experience a balanced point. It was also observed that increasing the reinforcement ratio enhances the axial capacity by 33% and the bending resistance by 141% while reducing the ties’ spacing from 140 mm to 40 mm has no significant influence on both the axial capacity and bending resistance. The study also expanded to verify theoretical models against experimental data, confirming their accuracy. These findings contribute to establishing reliable design guidelines for CFRP-RC columns influenced by axial loads and bending moments.
Abstract
The objective of this research is to identify the analysis of the ethics of the administration in the development of the social responsibility of one government organizations, and to achieve the objectives of the research was the use of a questionnaire developed for the purpose of data collection and distribution to the research sample, was chosen as a total sample population (50) individuals were relying on statistical package to do a statistical analysis for this research, user, ANSI (SPSS) simple regression analysis, standard deviation, Pearson correlation coefficient.
Research findings show the role of social responsibility in achieving the university's strategy,
... Show MoreThe international order have been changed during the modern and contemporary history, and however those changing in international order doesn't go to beyond several concepts such as " balance of power";" conflict"; "power" and " threaten", which all those are depending on the fundamentals or basic terms which was called " power" or" hard power". In this time, we can say that the political relations among the effective units could be analyzed according to the concept of " balance of threaten" instead of the classic concept which had called " balance of power" that the scholars used to describe the international relations . In conclusion , the concept of " balance of threaten" has a significant importance in the studies of the internationa
... Show MoreA high settlement may take place in shallow footing when resting on liquefiable soil if subjected to earthquake loading. In this study, a series of shaking table tests were carried out for shallow footing resting on sand soil. The input motion is three earthquake loadings (0.05g, 0.1g, and 0.2g). The study includes a reviewing of theoretical equations (available in literatures), which estimating settlement of footings due to earthquake loading, calibration, and verification of these equations with data from the shaking table test for improved soil by grouting and unimproved soil. It is worthy to note that the grouting materials considered in this study are the Bentonite and CKD slurries. A modification to the seismic set
... Show MoreAbstract The present work aims to study the performance of reinforced compacted clay soil by sand columns stabilized with sodium silicate to obtain more solid columns than the surrounding soil. The experimental work was carried out by using a lab model to evaluate the performance of both the floating and end bearing sand columns. The results showed that the improvement ratio for the soil reinforced with sand columns stabilized with sodium silicate reached 390% for the type of floating columns and 438% for end bearing columns.
The economy of a city has an important role not only in its establishment but also in its development. This is quite clear in the city of Baghdad throughout its history since its building in 762 A.D. In addition, most of its problems that the city is suffering from are basically related to not giving enough importance to the economic factors in the master planning of Baghdad since 1950’s. This may explain the failiars of master plans in dealing with the actual population growth and the city's inability to absorb such increases and interrelated and diverse activities which are negatively reflected on the economic variables particularly the effect on the land values, and the strong competitions amongst the land uses without previ
... Show MoreIn structural construction fields, reducing the overall self-weight of the structure is considered a primary objective and substantial challenge in the civil engineering field, particularly in earthquake-affected buildings and tall buildings. Different techniques were implemented to attain this goal; one of them is setting voids in a specific position through the structure, just like a voided slab or BubbleDeck slab. The main objective of this research is to study the structural behavior of BubbleDeck reinforced concrete slabs under the effect of static uniformly distributed load. The experimental program involved testing five fixed-end supported two-way solid and BubbleDeck slabs of dimensions 2500×2500×200 mm. The considered par
... Show MoreConcrete filled steel tube (CFST) columns are being popular in civil engineering due to their superior structural characteristics. This paper investigates enhancement in axial behavior of CFST columns by adding steel fibers to plain concrete that infill steel tubes. Four specimens were prepared: two square columns (100*100 mm) and two circular columns (100 mm in diameter). All columns were 60 cm in length. Plain concrete mix and concrete reinforced with steel fibers were used to infill steel tube columns. Ultimate axial load capacity, ductility and failure mode are discussed in this study. The results showed that the ultimate axial load capacity of CFST columns reinforced with steel fibers increased by 28% and 20 % for circular and square c
... Show MoreThis research explored the performance of steel fiber concrete-filled stainless-steel tube columns stiffened with embedded carbon steel T-sections with various steel fiber ratios under biaxial bending conditions. A numerical parametric analysis was adopted, using finite element modeling with Abaqus CAE/2021 to evaluate the effects of the fiber ratio (ranging from 0% to 1.5%) on the load-bearing capacity and deflection behavior of columns. In addition, the compressive strength of concrete ranged between 45 and 65 MPa. An increase in the fiber ratio led to a substantial improvement in the ultimate load-bearing capacity (up to 24%), a reduction in deflection (of approximately 49%), and an improvement in column ductility, which were obt
... Show More