A new spectrophotometric method for individual and simultaneous determination of cefixime and cephalexin depending on the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of cefixime and cephalexin in concentration interval of (4– 24μg.ml-1 ) by measuring the amplitude of peak-to-base line, pea to peak at certain wavelengths and the area under peak at selected spectrum intervals. The methods showed reasonable precision and accuracy and have been applied to determine cefixime and cephalexin in two different pharmaceutical preparations.
The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto
... Show More
Abstract
Friction stir welding is a relatively new joining process, which involves the joining of metals without fusion or filler materials. In this study, the effect of welding parameters on the mechanical properties of aluminum alloys AA2024-T351 joints produced by FSW was investigated.
Different ranges of welding parameters, as input factors, such as welding speed (6 - 34 mm/min) and rotational speed (725 - 1235 rpm) were used to obtain their influences on the main responses, in terms of elongation, tensile strength, and maximum bending force. Experimental measurements of main responses were taken and analyzed using DESIGN EXPERT 8 experimental design software which was used to develop t
... Show MoreAn electrochemical sensor based on manganese dioxide nanorodMnO2and Graphene oxide (GO) functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (FGO)/MnO2Nanocompositewas developed for voltammetric determination of Tetracycline (TET).The working electrode WE of SPCE was modified bya drop casting method. X-ray powder diffractometer (XRD), scanning electron microscopy (SEM) and FT-IR were employed to characterize the synthesized FGO/MnO2. The determination of TET at the modified electrode was studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in the phosphate buffer solution (PBS).TET show sharp increase in the oxidation peaks in the pH 2.Voltammetric characteristics of TET (Epa, Ipa) were estimate
... Show MoreObjectives: To determine the contributing risk factors to adult nephrolithiasis patients.
Methodology: A descriptive study was conducted to determine the contributing risk factors to
Adults nephrolithiasis starting from December 2007 to September 2008. A purposive "nonprobability"
sample of (100) patients with nephrolithiasis was selected of those who were
admitted to the hospitals, attending the Urology Consultation Clinic and Extracorporeal Shock
Wave Lithotripsy Department. The study instrument consists of two parts. The first part is
related to the patients' demographic variables and the second part is constructed to serve the
purpose of the study. The total number of items in the questionnaire was (85) ones.
Most of the known cases of strong gravitational lensing involve multiple imaging of an active galactic nucleus. The properties of lensed active galactic nuclei make them promising systems for astrophysical applications of gravitational lensing. So we present a simple model for strong lensing in the gravitational lensed systems to calculate the age of four lensed galaxies, in the present work we take the freedman models with (k curvature index =0) Euclidian case, and the result show a good agreement with the other models.
Vitamins are a type of essential and important nutrient in the human body. It also plays an essential role in the health and protection of the human body. They share physiological functions with many chemicals, and their deficiency or increase endangers human health. Therefore, it is required to evolve and use modern methods to estimate the concentration of vitamins, even if their concentration is very low, and these include the vitamin E group tocopherols, tocotrienols, isomers, esters, and derivatives. They disagree not in their ability as anti-cancer agents but rather in their physiological as well as chemical relations, unlike vitamin A and vitamin D. The richest source of vitamin E is vegetable oil. Vitamin E, classified as a vitami
... Show MoreA spectrophotometric method is proposed for the determination of some drugs containing amino group such as mesalazine, metoclopramide and dopamine in pharmaceutical formulations. It was simple, precise, accurate, rapid, and based on the oxidation of each drug with chromate as an oxidizing agent in the presence of 1N hydrochloric acid. Then indigo carmine is reacted with residual chromate in the presence of a catalysis factor (sodium oxalate). Increasing in absorbance's value of the color system is proportional to the amount of the three drugs which is measured at the selected wavelength of 610 nm.
The proposed method is obeying Beer's law in the ranges of (1-40, 2-44 and 2-52) ppm for the concentration of
... Show MoreDirect determination of trace metals Zn, Mn, Cu and Co were performed in serum
blood samples of two groups diabetic patient type 2 and non diabetes by ICP spectrometric
method. Results show the low levels of these elements Zn, Mn and Co while high level of Cu
detected compared with non diabetes according to these results good evidence can be made to
control these levels through a special diet containing these metals.
In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral
... Show More