This research considers a proposed mechanism relying on frictional interactions between the grasped object and the gripper, thus attaining a case of self-locking condition for a tendon type robotic gripper. A mathematical model was derived for this proposed mechanism, upon which a special purpose apparatus was fabricated and tested. Both results, theoretically and experimentally, are in good agreement, showing that the weight of the grasped object played a major role in attaining the self-locking condition.
The mechanism of managing religious difference
God is the Lord of the worlds, forget them and their jinn, Arabs and non-Muslims, He is the Lord of Muslims and Lord of non-Muslims, as He created them male and female despite their differences in tongues and colors, so He created them according to their diversity and distinction in beliefs and religions.
To prevent flare-ups due to differences, the Lord of the worlds set limits that he has forbidden to cross, and draw clear maps as mechanisms for managing religious differences and lifting psychological barriers between the different, so that they can coexist in peace and freedom, each adhering to his faith, and practicing the rituals of his religion.
... Show MoreThis paper presents a robust control method for the trajectory control of the robotic manipulator. The standard Computed Torque Control (CTC) is an important method in the robotic control systems but its not robust to system uncertainty and external disturbance. The proposed method overcome the system uncertainty and external disturbance problems. In this paper, a robustification term has been added to the standard CTC. The stability of the proposed control method is approved by the Lyapunov stability theorem. The performance of the presented controller is tested by MATLAB-Simulink environment and is compared with different control methods to illustrate its robustness and performance.
Objectives: To assess the feasibility and accuracy of a new prototype robotic implant system for the placement of zygomatic implants in edentulous maxillary models. Methods: The study was carried out on eight plastic models. Cone beam computed tomographs were captured for each model to plan the positions of zygomatic implants. The hand-eye calibration technique was used to register the dynamic navigation system to the robotic spaces. A total of 16 zygomatic implants were placed, equally distributed between the anterior and the posterior parts of the zygoma. The placement of the implants (ZYGAN®, Southern Implants) was carried out using an active six-jointed robotic arm (UR3e, Universal Robots) guided by the dynamic navigation coordinate tr
... Show MoreThe current research was aimed at the following:
1. Measurement of Personality Type Observer of the University students.
2. Identify the differences in Personality Type Observer among the University students according to variable of Sex (male / female). And according to variable of Specialization (scientific / literary)
3. Measurement of Withdrawal of the University students.
4. Identify the differences in Withdrawal among the University students according to variable of Sex (male / female). And according to variable of Specialization (scientific / literary).
5. Identify the relationship between Personality Type Observer and Withdrawal.
To achieve this aims of the research, the researchers set up the instrument is scale
Abstract. This work presents a detailed design of a three-jointed tendon-driven robot finger with a cam/pulleys transmission and joint Variable Stiffness Actuator (VSA). The finger motion configuration is obtained by deriving the cam/pulleys transmission profile as a mathematical solution that is then implemented to achieve contact force isotropy on the phalanges. A VSA is proposed, in which three VSAs are designed to act as a muscle in joint space to provide firm grasping. As a mechatronic approach, a suitable type and number of force sensors and actuators are designed to sense the touch, actuate the finger, and tune the VSAs. The torque of the VSAs is controlled utilizing a designed Multi Input Multi Output (MIMO) fuzzy controll
... Show MoreObjectives: to evaluate patient knowledge with hemodialysis and to determine the effectiveness of Self-regulation Fluid Program on Patients with hemodialysis self-efficacy for fluid adherence in Al-Diwaniyah Teaching Hospital.
Methodology: A quasi-experimental design (two group design: pre-test and post-test) was used. This study was conducted in Al-Diwaniya Teaching Hospital for the period from (15th of October 2018 to 20th of May 2019) on a non-probability (purposive) sample consisting of (60 patients) treatment in hemodialysis units. A questionnaire was built as a data collection tool and consisted of four parts:
First part: Demographic characteristics of the pati
... Show MoreThe current study objective is to synthesize activated carbon (AC) from compressed wood using the ZnCl2 activating agent and to assess the ciprofloxacin (CIP) elimination efficiency in simulated wastewater. The produced AC was characterized using multiple techniques, including SEM, BET, FTIR, AFM, and XRD. The adsorbent demonstrates high adsorption performance, achieving 91% removal of CIP within 5 hours at an initial pollutant concentration of 100 mg/L with an AC dose of 2 g/L. Experimental data correspond to the Freundlich isotherm model (R² = 0.995) as well as the Langmuir competitive fitting (R² = 0.99), while the root mean square error (RMSE) equation best fits the Langmuir model. Moreover, the pseudo-second-order
... Show More