The effect of D phase polyamide (PA6)on the rheological properties, Young Modulus and the thermal expansion coefficient of two blends groups (bitumen-polyamide) were tested. The first group was for bitumen-PA6 blends and the second group for bitumen blended with polymer resulted from the crystallization of PA6-formic acid solution in water(PAFW).The obtained results proved that adding both types of polyamide has led to a rise in toughness and softening point temperature while the penetration Index approached -3 after adding the polyamide. So, all these changes make bitumen-polyamide blends more suitable for use in hot climate regions. The blends properties were explained according to the reaction that takes place between the polyamide and the epoxy present in the bitumen at temperatures exceeding 200 ° C. However, these changes were more pronounced for mixtures that contained PAFW due to their porous morphological structure, which increased the reaction and made the blends more miscibility even when the addition ratio reached to4%. In the case of PA6, when its ratio in bitumen increased by more than 1%, the unreacted portion of this polymer with epoxy would be mere filler in the mixtures and it did not appear to have a pronounced effect on the properties of bitumen.
Assessment of Salivary Macrophage Inflammatory Protein-1 Alpha Level in Different Stages of Periodontitis, Riyam Muthanna Muhammed*, Hadeel Mazin Akram
The magnetic properties of a pure Nickel metal and Nickel-Zinc-Manganese ferrites having the chemical formula Ni0.1(Zn0.4Mn0.6)0.9Fe2O4 were studied. The phase formation and crystal structure was studied by using x-ray diffraction which confirmed the formation of pure single spinel cubic phase with space group (Fd3m) in the ferrite. The samples microstructure was studied with scanning electron microstructure and EDX. The magnetic properties of the ferrite and nickel metal were characterized by using a laboratory setup with a magnetic field in the range from 0-500 G. The ferrite showed perfect soft spinel phase behavior while the nickel sample showed higher magnetic loss an
... Show MoreAbstract Objectives: to determine efficiency and safety of three misoprostol regimens for 2nd trimester pregnancy termination in individuals with two or more cesarean section scars. Methods: a cross-sectional study included 100 pregnant ladies at 13th-26th weeks gestation with previous two cesarean sections (CSs) who were scheduled for pregnancy termination using misoprostol. Patients were conveniently assigned to 100µg/3h, 200µg/3h or 400 µg/3h regimens. Primary outcome was time to abortion, secondary outcomes were side effect and complications. Results: a significant association was found between number previous CSs and longer time to abortion (p=0.01). A highly significant association was identified between earlier gestatio
... Show MoreIn this paper a system is designed and implemented using a Field Programmable Gate Array (FPGA) to move objects from a pick up location to a delivery location. This transportation of objects is done via a vehicle equipped with a robot arm and an FPGA. The path between the two locations is followed by recognizing a black line between them. The black line is sensed by Infrared sensors (IR) located on the front and on the back of the vehicle. The Robot was successfully implemented by programming the Field Programmable Gate Array with the designed system that was described as a state diagram and the robot operated properly.
The present paper addresses one of the most challenging topics in translation; namely legal translation in the framework of two different approaches; the classical (formal) and the more recent (functional). The latter approach is the outcome of the process of simplifying legal language known technically as Plain Language Movement. The advent of this movement dates back to the 1950s, in response to the widely-held complain about the awkwardness of the legal register. Within this framework, the salient features of legal language, at the various linguistic and textual levels, underwent reconsideration in favor of more publicly digested expressions. The paper then subjects two translations of a lease contract to analysis in the ligh
... Show MoreHard-grade asphalt binders like AC20-30 typically exhibit excessive stiffness, reduced penetration, and compromised workability, necessitating modification before use in paving applications. This study evaluates the efficacy of regular polyalphaolefin (PAO), a synthetic olefin-based lubricant, as a performance-enhancing modifying agent for such binders. AC20-30 was blended with PAO at dosages ranging from 2 wt.% to 10 wt.%, and the modified binders were characterized via penetration, ductility, softening point, and rotational viscosity measurements, alongside advanced rheological and chemical-morphological analyses. Incorporating PAO in AC20-30 asphalt progressively reduced the binder stiffness and enhanced its flexibility, with all modifie
... Show MoreThe design of components subjected to contact stress as local compressive stress is important in engineering application especially in ball and socket Joining. Two kinds of contact stress are introduced in the ball and socket joint, the first is from normal contact while the other is from sliding contact. Although joining two long links (drive shaft in steering cars) will cause the effect of flexural and tensional buckling stress in hollow columns through the ball and socket ends on the failure condition of the joining mechanism. In this paper the consideration of the combined effect of buckling Load and contact stress on the ball and socket joints have been taken, epically on the stress distribution in the contact area. Different
... Show MoreBackground: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show More