Search Results at the International Journal of Science and Research (IJSR)
Reactive Powder Concrete (RPC) can be incorporate as a one of the most important and progressive concrete technology. It is a special type of ultra-high strength concrete (UHSC) that’s exclude the coarse aggregate from its constitutive materials. In this research an experimental study had been carried out to investigate the effect of using three types of materials (porcelain aggregate) and others sustainable materials (glass waste and granular activated carbon) as a partial replacement of fine aggregate. Four percentages had considered (0, 10, 15 and 20) % to achieve better understanding for the influence of these materials upon the compressive strength of RPC. Four curing ages had included in this study, these are; 7, 28, 60 and
... Show MoreReactive Powder Concrete (RPC) can be incorporate as a one of the most important and progressive concrete technology. It is a special type of ultra-high strength concrete (UHSC) that’s exclude the coarse aggregate from its constitutive materials. In this research an experimental study had been carried out to investigate the effect of using three types of materials (porcelain aggregate) and others sustainable materials (glass waste and granular activated carbon) as a partial replacement of fine aggregate. Four percentages had considered (0, 10, 15 and 20) % to achieve better understanding for the influence of these materials upon the compressive strength of RPC. Four curing ages had included in this study, these are; 7, 28, 60 and
... Show MoreAn infant incubator in the neonatal intensive care unit (NICU) is a medical instrument of care that provides oxygen, warmth and moisture to a newborn baby. Due to environmental conditions affecting the infants foster babies may experience discomfort and pain at some point. Thus, this study aimed to assess ambient air quality in neonatal incubators to improve the environmental quality of neonatal intensive care units and safety. Air pollutants concentrations consisting of particulate matter (pm2.5, pm10), hydrocarbons (HOCH), volatile organic compounds (VOC), air quality index (AQI), humidity and temperature, were measured at four selected Baghdad hospitals (Al-Karkh and Rusafa) . The results showed that the
... Show MoreAbstract
In this study the radon gas concentration in air in Al - Haswaa city in province of Baghdad in Iraq have been calculated using CR-39 solid–state nuclear track detector technique. A total of 8 samples selected from 8 region in Al – Haswaa city in province of Baghdad have been placed in the dosimeters for 30 day. The average radon gas concentration was found to be 486.26 Bq/m3 which is lower than the standard international limit (1100 Bq/m3). The potential alpha energy concentration and annual effective dose have been calculated. A proportional relationship between the annual effective dose and radon gas concentration within the studied region has been certified.
The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro
... Show MoreAn experimental and numerical study has been carried out to investigate the forced convection heat transfer by clean or dusty air in a two dimensional annulus enclosure filled with porous media (glass beads) between two vertical concentric cylinders. The outer cylinder is of (82 mm) outside diameters and the inner cylinder of (27 mm) outside diameter. Under steady state condition; the inner cylinder surface is maintained at a high temperature by applying a uniform heat flux and the outer cylinder surface at an ambient temperature. The investigation covered values of input power of (6.3, 4.884, 4.04 and 3.26 W), Reynolds number values of (300, 700, 1000, 1500, and 2000) and dust ratio values (density number N) of (2, 4, 6 and 8). A comput
... Show MoreThe current study was conducted to demonstrate the effects of air pollution on different biochemical parameters inCitrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected tocollect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and closeto the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonalsamples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters totalchlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugarcontent, proline, electrical conductivity, cadmium and lead. The results of Citr
... Show MorePolycyclic aromatic hydrocarbons (PAHs) were measured in aerosol from air samples, which collected for the period from April 2012 to February 2013, in Baghdad city, at Daura Refinery. Aerosol samples were collected on cellulose fiber filters for 1.5 h in each site for the morning and evening time. These aerosol samples undergone soxhlet extraction.
After the extraction, 49 samples were analyzed by GC-MS in order to determin 16 PAH compounds. The parameters temperature, relative humidity and wind speed were measured during the measurement period. The PAH concentrations were different for location inside and outside Daura refinery. Naphthalene was the most abundant PAH detected in all points at the site sampling for all seasons. There i
The current study was conducted to demonstrate the effects of air pollution on different biochemical parameters in Citrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected to collect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and close to the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonal samples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters total chlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugar content, proline, electrical conducti
... Show More