Preferred Language
Articles
/
wBarCYcBVTCNdQwC_TB-
Behavior of asymmetrical castellated composite girders by gap in steel web
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Corrosion Inhibition of Medium Carbon Steel in the Acidic Medium Using Alcoholic and Aqueous Extract of Kujarat Tea Plant
...Show More Authors

This study deals with the corrosion inhibition of metal corrosion process of medium carbon steel using 1M HCl for kinetic studies and rate reaction determination. The weight loss method is applied to pieces of Medium carbon steel divided to Cubans with dimensions (0.4*2*2.4) cm , and use Tafel Extrapolation Method, the samples were polished using carbide silicon paper with dimensions of (180,200,400,600,800,1000). The samples were immersed in the alcoholic medium ethanol at a temperature 293K for 3hr. Natural inhibitor Kujarat Tea (Hibiscus sabdarriffa L.) is used which is extracted in aqueous and alcoholic medium, different concentrations (1000،2000, 3000) ppm have been used ; The best concentration found through the results is a conce

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Lecture Notes In Electrical Engineering
A Study of the Influence of Steel Brushes in Rail Surface Magnetic Flux Leakage Detection Using Finite Elements Simulation
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Synthesis, Characterization, and Investigation the Inhibitory Impact of Thiosemicarbazide Derivative toward the Corrosion of Mild Steel in Acidic Media
...Show More Authors

        In this study we focused on the determination of influence the novel synthesized thiosemicarbazide derivative "2-(2-hydroxy-3-methoxybenzylidene) hydrazinecarbothioamide" (HMHC) influenced the corrosion inhibition of mild steel (MS) in a 1.0 M hydrochloric acid acidic solution.This is in an effort to preserve the metal material by maintaining it from corrosion.The synthesized inhibitor was characterized using elemental analysis, and NMR-spectroscopy. Then the corrosion inhibition capability of (HMHC) was studied on mild steel in an acidic medium by weight loss technique within variables [temperature, inhibitor concentration, and time]. The immersion periods were [1:00, 3:00, 5:00, 10:00, 24:00, and 72:00] hours and the tem

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Effect of Hydroxyapatite Coatings on Corrosion Behavior for Biotype 316L SS Used in Orthopaedic Applications
...Show More Authors

Electrochemical corrosion of hydroxyapatite (HAP) coated performance depends on various parameters like applied potential, time, thickness and sintering temperature. Thus, the optimum parameters required for the development of stable HAP coatings was found by using electrophoretic deposition (EPD) technique. This study discusses the results obtained from open circuit potential-time measurements (OCP-time), potentiodynamic polarisation and immersion tests for all alloy samples done under varying experimental conditions, so that the optimum coating parameters can be established. The ageing studies of the coated samples were carried out by immersing them in Ringer’s solution for a period of 30 days indicates the importance of stable HAP c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 31 2014
Journal Name
Al-khwarizmi Engineering Journal
Corrosion Behavior of V2AlC and Cr2AlC Compared with SS 316L in NaOH at Four Temperatures
...Show More Authors

Abstract

      This work involves the manufacturing of MAX phase materials include V2AlC and Cr2AlC using powder metallurgy as a new class of materials which characterized by regular crystals in lattice. Corrosion behavior of these materials was investigated by Potentiostat to estimate corrosion resistance and compared with the most resistant material represented by SS 316L. The experiments were carried out in 0.01N of NaOH solution at four temperatures in the range of 30–60oC. Polarization resistance values which calculated by Stern-Geary equation indicated that the MAX phase materials more resistant than SS 316L. Also cyclic polarization tests confirme

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Al-farahidi's Arts
The Impact of Social Media on Customer Behavior - Survey Research for Tourism Companies in Baghdad
...Show More Authors

The current research aims to diagnose the type and level of influence of social media, whose dimensions are represented by (attitudes towards social media marketing, knowledge and use of social media, influence on the Internet and social media, following up on social media) on customer behavior in its dimensions (attracting attention, raising Interest, desire creation, customer response), and the research sought to answer questions related to the research problem by testing the main hypotheses to explore correlations and influence between the two variables, and to achieve research hypothesis tests, the field study was used, as the research sample reached (135) individuals from the director and the assistant director And marketing personnel

... Show More
Publication Date
Tue Mar 01 2022
Journal Name
Results In Engineering
Predictive model for stress at ultimate in internally unbonded steel tendons based on genetic expression programming
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Expired Colxacillin, Amoxicillin, and Ceflaxin Drugs as Inhibitors for Low Carbon Steel Corrosion in Sodium Chloride
...Show More Authors

The ability to inhibit corrosion of low carbon steel in a salt solution (3.5%NaCl) has been checked with three real expired drugs (Cloxacillin, Amoxicillin, Ceflaxin) with variable concentrations (0, 250, 500, 750) mg/L were examined in the weight loss. The inhibition efficiency of the Cloxacillin 750 mg/L showed the highest value (82.8125 %) and the best inhibitor of the rest of the antibiotics. The different concentrations of Cloxacillin drug (0, 250, 500, 750) mg/L and temperature (25, 35, 45, 55) oC were studied as variables with potentiodynamic polarization, Scanning Electron Microscopy (SEM) for surface morphology and electrochemical impedance spectroscopy (EIS) depending on current values and the resistance of charge to

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jun 24 2020
Journal Name
Basic Education College Magazine For Educational And Humanities Sciences
The healthy behavior of the Arab citizen in light of the Corona crisis 2020-6-24
...Show More Authors

Abstract: The world witnessed the speed of a dangereuse virus now as Corona or Covid 19, which left many deaths in light of the inability of local and international Heath agencies to find a suitable vaccine to eliminate it and limit its spread, which negatively affected humain life in its various fields, and remains adopting healthy behaviors and habits A healthy Heath is the best solution to face the spread of the epidemic until realistic solutions that eliminate the virus are found.

Publication Date
Tue Jan 27 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of in office bleaching on surface roughness and micro-hardness of newly developed composite materials (In vitro study)
...Show More Authors

Background: Alterations in the microhardness and roughness are commonly used to analyze the possible negative effects of bleaching products on restorative materials. This in vitro study evaluated the effect of in-office bleaching (SDI pola office +) on the surface roughness and micro-hardness of four newly developed composite materials (Z350XT –nano-filled, Z250XT-nano-hybrid, Z250-mico-hybrid and Silorane-silorane based). Materials and methods: Eighty circular samples with A3 shading were prepared by using Teflon mold 2mm thickness and 10mm in diameter. 20 samples for each material, 10 samples for base line measurement (surface roughness by using portable profillometer, and micro-hardness by usingDigital Micro Vickers Hardness Test

... Show More
View Publication Preview PDF