The provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were: number of web openings, the method used to strengthen the member at openings and the height of drop during impact tests. All beams were simply supported with load applied at mid – span. Static results indicated that T-beams with four and six un-strengthened web circular openings whose diameter is 48% of the web depth have strength capacities less than those without openings by 30% and 41%, respectively. However, strengthening of webs results in an increase in the strength capacities ranging between 27% and 92%, depending on the type of strengthening. Impact results indicated that the beam with four openings did not show a remarkable increase in the maximum mid-span deflection compared with the solid beam, while that with six openings showed an increase in the maximum mid-span deflections by about 75% greater than the maximum mid-span deflection of the solid beam. Strengthening of specimens could overcome the increase in deflections.
Background: One of the most common complications of dentures is its ability to fracture, so the aim of this study was to reinforce the high impact denture base with carbon nanotubes in different concentrations to improve the mechanical and physical properties of the denture base. Materials and methods: Three concentrations of carbon nanotubes was used 0.5%, 1%, 1.5% in a pilot study to see the best values regarding transverse strength, impact, hardness and roughness test, 1 wt% was the best concentration, so new samples for control group and 1wt% carbon nanotubes and the previous tests were of course repeated. Results: There was a significant increase in impact strength and transverse strength when we add carbon nanotubes in 1wt%, compared
... Show MoreIn this paper, a procedure to establish the different performance measures in terms of crisp value is proposed for two classes of arrivals and multiple channel queueing models, where both arrival and service rate are fuzzy numbers. The main idea is to convert the arrival rates and service rates under fuzzy queues into crisp queues by using graded mean integration approach, which can be represented as median rule number. Hence, we apply the crisp values obtained to establish the performance measure of conventional multiple queueing models. This procedure has shown its effectiveness when incorporated with many types of membership functions in solving queuing problems. Two numerical illustrations are presented to determine the validity of the
... Show MoreThe k-out-of-n:G (or k/n:G) system structure is a very popular of redundancy in
fault-tolerant systems, with wide applications in so many fields. This paper presents
two states of multi-state k/n:G systems. The first part, we present the definition that
introduced by Al-Neweihi et al [1], where the values are the same with respect
to all system states and we show that there exists an alternative equivalent definition
to Al-Neweihi's definition. In the second part of this paper we give more general
definition proposed by Huang et al [2], where it allows different values with
respect to different system states and we provide there exists an equivalent definition
to Huang's definition when the values are increasing.
The central nervous system (CNS) disease known as multiple sclerosis (MS) is essentially an inflammatory demyelinating condition with a variety of clinical manifestations and variable histological findings. A number of immunological and biochemical markers may alter MS, which is also characterized as an autoimmune illness. MS patients (n = 100) were divided into two groups: newly diagnosed (n = 42) and patients with ongoing treatments (n = 58). These groups were compared to healthy subjects (n = 55); the mean age ±SD was (30±8.46 years), (37±8.06 years), and (31±8.73 years) for MS newly diagnosed patients, patients with ongoing treatments, and healthy subjects, respectively. Studies for serum levels of eotaxin-1, myelin basi
... Show MoreIn the geotechnical engineering applications, precise understandings are yet to be established on the effects of a foundation stiffness on its bearing capacity and settlement. The modern foundation construction uses the new available construction materials that totally change the relative stiffness of the footing structures-soil interactions such as waste material and landfill area of more residential purposes. Conventional bearing capacity equations were dealt with common rigid footing and thus cannot be used for reduced foundation rigidity. Therefore, this study investigates the effects of foundation relative stiffness on its load-displacement behaviour and the soil deformation field using compression test of a strip smooth footings on su
... Show MoreObjective: Knee osteoarthritis is a common disabling chronic disease globally. Many pharmacological agents have been used efficiently in treatment of knee osteoarthritis. This study aims to evaluate metformin and serratiopeptidase together in treatment and stop of osteoarthritis progression by different mechanisms. Methods: Present study was a randomized clinical trial study conducted in Al-Kindi teaching hospital through the period from 1st January to 30th of May, 2017 on two groups of 80 osteoarthritis patients (group I; treated with metformin 850 mg oral tablets) and (group II; treated with metformin 850 mg oral tablets and serratiopeptidase 20 mg oral tablets). Parameters of two groups were compared with those of 40 normal healt
... Show MoreBackground: Multiple myeloma (MM) is a malignant clonal expansion of plasma cells. Previous studies had demonstrated that both bone marrow angiogenesis as measured by microvessel density (MVD) and PCNA were increased in variety of malignant disorders, including multiple myeloma.
Objective: Assessment of angiogenesis in bone marrow of MM patients by using immunohistochemical stain to measure microvessel density (MVD) using factor VIII –related antigen and to evaluate the expression of PCNA antigen in plasma cells of MM bone marrow sections . Also to find the correlation between these two parameters and between them and the percentage of plasma cells infiltration in bone marrow of MM.
Patients, materia
The paper presents the design of a system consisting of a solar panel with Single Input/Multiple Outputs (DC-DC) Buck Converter by using Simulink dialogue box tools in MATLAB software package for simulation the system. Maximum Power Point Tracking (MPPT) technique depending on Perturb and Observe (P&O) algorithm is used to control the output power of the converter and increase the efficiency of the system. The characteristics of the MSX-60 PV module is chosen in design of the system, whereas the electrical characteristics (P-V, I-V and P-I curves) for the module are achieved, that is affected by the solar radiation and temperature variations. The proposed design module has been found to be stable for any change in atmospheric tempera
... Show MoreMassive multiple-input multiple-output (massive-MIMO) is considered as the key technology to meet the huge demands of data rates in the future wireless communications networks. However, for massive-MIMO systems to realize their maximum potential gain, sufficiently accurate downlink (DL) channel state information (CSI) with low overhead to meet the short coherence time (CT) is required. Therefore, this article aims to overcome the technical challenge of DL CSI estimation in a frequency-division-duplex (FDD) massive-MIMO with short CT considering five different physical correlation models. To this end, the statistical structure of the massive-MIMO channel, which is captured by the physical correlation is exploited to find sufficiently
... Show More