Preferred Language
Articles
/
vRd_X5MBVTCNdQwCs9IQ
Capability of a novel small field of view hybrid gamma camera (HGC) for sentinel lymph node and small organ imaging

Objectives: Small field of view gamma detection and imaging technologies for monitoring in vivo tracer uptake are rapidly expanding and being introduced for bed-side imaging and image guided surgical procedures. The Hybrid Gamma Camera (HGC) has been developed to enhance the localization of targeted radiopharmaceuticals during surgical procedures; for example in sentinel lymph node (SLN) biopsies and for bed-side imaging in procedures such as lacrimal drainage imaging and thyroid scanning. In this study, a prototype anthropomorphic head and neck phantom has been designed, constructed, and evaluated using representative modelled medical scenarios to study the capability of the HGC to detect SLNs and image small organs. Methods: An anthropomorphic head and neck phantom has been designed to mimic the adult head and neck including some internal organs and tissues of interest, such as the thyroid gland and sentinel lymph nodes. The design of the head and neck phantom included an adjustable inner jig holding the simulated SLNs and thyroid gland. The simulated thyroid gland was designed and 3D printed taking into consideration the size and the shape of a healthy adult thyroid gland. The inner sealed space of the thyroid was filled with 15MBq of 99mTc through two upper filling valves. Sealed micro-tubes (0.2ml) have been employed to simulate SLNs containing various 99mTc activity concentrations ranging between 0.1MBq and 1MBq, and can be positioned at any desired place in the head and neck region. An active background was simulated through mixing 10MBq of 99mTc solution with the water used to fill the outer shell of the head and neck phantom. Results: The head and neck phantom was employed to simulate a situation where there are four SLNs distributed at two different vertical levels and at two depths within the neck. Contrast to noise ratio (CNR) calculations were performed for the detected SLNs at an 80mm distance between both pinhole collimators (i.e. 0.5mm and 1.0mm diameters) and the surface of the head and neck phantom with a 100s acquisition time. The recorded CNR values for the simulated SLNs are higher when the HGC was fitted with the 1.0mm diameter pinhole collimator. For instance, the recorded CNR values for the superficially simulated SLN containing 0.1MBq of 99mTc using 0.5mm and 1.0mm diameter pinhole collimators are 6.48 and 16.42, respectively (~87% difference). The anatomical context provided by the hybrid imaging aided the localization process of radioactivity accumulation in simulated SLNs. Gamma and hybrid optical images were acquired using the HGC with both available pinhole collimators for the simulated thyroid gland. The thyroid images produced varied in terms of spatial resolution and detectability. The count profiles through the middle of the simulated thyroid gland images provided by both pinhole collimators were obtained. The HGC could clearly differentiate the individual peaks of both thyroid lobes in the gamma image produced by the 0.5mm pinhole collimator. In contrast, the recorded count profile for the acquired image using the 1.0mm diameter pinhole collimator showed broader peaks for both lobes, reflecting the degradation of the spatial resolution with increasing the diameter of the pinhole collimator. Conclusion: The capability of the HGC has been evaluated utilizing a prototype anthropomorphic head and neck phantom, and the gamma and hybrid images obtained demonstrate that it is ideally suited for intraoperative SLNs detection and small organ imaging. The standardization of test phantoms and protocols for SFOV portable gamma systems will provide an opportunity to collect data across various medical centers and research groups. Moreover, it will provide a technical baseline for researchers and clinical practitioners to consider when assessing their SFOV gamma imaging systems. The anthropomorphic head and neck phantom described is cost effective, reproducible, flexible and anatomically representative.

Publication Date
Tue Jun 30 2015
Journal Name
International Journal Of Computer Techniques
Multifractal-Based Features for Medical Images Classification

This paper presents a method to classify colored textural images of skin tissues. Since medical images havehighly heterogeneity, the development of reliable skin-cancer detection process is difficult, and a mono fractaldimension is not sufficient to classify images of this nature. A multifractal-based feature vectors are suggested hereas an alternative and more effective tool. At the same time multiple color channels are used to get more descriptivefeatures.Two multifractal based set of features are suggested here. The first set measures the local roughness property, whilethe second set measure the local contrast property.A combination of all the extracted features from the three colormodels gives a highest classification accuracy with 99.4

... Show More
Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Highly selective CdS:Ag heterojunction for photodetector applications

Scopus (34)
Crossref (24)
Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jan 01 2009
Journal Name
مجلة العلوم الاحصائية
Robust Estimator for Semiparametric Generalized Additive Model

Generalized Additive Model has been considered as a multivariate smoother that appeared recently in Nonparametric Regression Analysis. Thus, this research is devoted to study the mixed situation, i.e. for the phenomena that changes its behaviour from linear (with known functional form) represented in parametric part, to nonlinear (with unknown functional form: here, smoothing spline) represented in nonparametric part of the model. Furthermore, we propose robust semiparametric GAM estimator, which compared with two other existed techniques.

View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Applied Mechanics And Materials
Artistic Techniques for Developing Creativity in Design

The design of future will still be the most confusing and puzzling issue and misgivings that arouse worry and leading to the spirit of adventures to make progress and arrive at the ways of reviving, creativity and modernism. The idea of prevailing of a certain culture or certain product in design depends on the given and available techniques, due to the fact that the computer and their artistic techniques become very important and vital to reinforce the image in the design. Thus, it is very necessary to link between these techniques and suitable way to reform the mentality by which the design will be reformed, from what has been said, (there has no utilization for the whole modern and available graphic techniques in the design proce

... Show More
Scopus Clarivate Crossref
View Publication
Publication Date
Fri Nov 01 2019
Journal Name
Journal Of Craniofacial Surgery
Risk Factors for Fistula Development Following Palatoplasty
Purpose:

The aim of this study is to assess the influence of some risks factors on the fistula development after palatoplasty to improve the outcome of the patients

Patients and Methods:

A total of 48 patients (the males were 22, The females were 26) were included in this study. All the patients were examined weekly for the first month postoperatively to assess any breakdown in the wound by inspection and by asking the parents for any nasal regurgitation during fluids feeding.

Results:
... Show More
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
View Publication
Publication Date
Wed Sep 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Using Ultraviolet Technique for Well Water Disinfection

Scopus (1)
Crossref (1)
Scopus Crossref
View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Ovonic Research
Manufacturing Br:CO3O4 /Si Heterojunction For Photodetector Applications

This research including, CO3O4 was prepared by the chemical spry pyrolysis, deposited film acceptable to assess film properties and applications as photodetector devise, studying the optical and optoelectronics properties of Cobalt Oxide and effect of different doping ratios with Br (2, 5, 8)%. the optical energy gap for direct transition were evaluated and it decreases as the percentage Br increase, Hall measurements showed that all the films are p-type, the current–voltage characteristic of Br:CO3O4 /Si Heterojunction show change forward current at dark varies with applied voltage, high spectral response, specific detectivity and quantum efficiency of CO3O4 /Si detector with 8% of Br ,was deliberate, extreme value with 673nm.

... Show More
Scopus Clarivate Crossref
View Publication
Publication Date
Fri Jan 01 2016
Journal Name
Modern Applied Science
New Combined Technique for Fingerprint Image Enhancement

This paper presents a combination of enhancement techniques for fingerprint images affected by different type of noise. These techniques were applied to improve image quality and come up with an acceptable image contrast. The proposed method included five different enhancement techniques: Normalization, Histogram Equalization, Binarization, Skeletonization and Fusion. The Normalization process standardized the pixel intensity which facilitated the processing of subsequent image enhancement stages. Subsequently, the Histogram Equalization technique increased the contrast of the images. Furthermore, the Binarization and Skeletonization techniques were implemented to differentiate between the ridge and valley structures and to obtain one

... Show More
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Double probe for measuring the plasma parameters

In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing

... Show More
View Publication Preview PDF
Publication Date
Thu May 05 2022
Journal Name
Karbala International Journal Of Modern Science
An economical source for peroxidase: maize cobs

According to the current situation of peroxidase (POD), the relevant studies on this enzyme indicated its importance as a tool in clinical biochemistry and different industrial fields. Most of these studies used the fruits and vegetables as source of this enzyme. So that in order to couple the growing requirements for POD with the recent demands for reduc-ing disposal volume by recycling the plant waste, the aim of the present study was to extract POD through management of municipal bio-waste of Iraqi maize species. A simple, green and economical method was used to extract this enzyme. Our results revealed that maize cobs are rich sources of POD, where the activity of this enzyme was found to be 7035.54 U/g of cobs. In pilot experiments thi

... Show More
Scopus (2)
Crossref (1)
Scopus Crossref
View Publication Preview PDF