Objectives: Small field of view gamma detection and imaging technologies for monitoring in vivo tracer uptake are rapidly expanding and being introduced for bed-side imaging and image guided surgical procedures. The Hybrid Gamma Camera (HGC) has been developed to enhance the localization of targeted radiopharmaceuticals during surgical procedures; for example in sentinel lymph node (SLN) biopsies and for bed-side imaging in procedures such as lacrimal drainage imaging and thyroid scanning. In this study, a prototype anthropomorphic head and neck phantom has been designed, constructed, and evaluated using representative modelled medical scenarios to study the capability of the HGC to detect SLNs and image small organs. Methods: An anthropomorphic head and neck phantom has been designed to mimic the adult head and neck including some internal organs and tissues of interest, such as the thyroid gland and sentinel lymph nodes. The design of the head and neck phantom included an adjustable inner jig holding the simulated SLNs and thyroid gland. The simulated thyroid gland was designed and 3D printed taking into consideration the size and the shape of a healthy adult thyroid gland. The inner sealed space of the thyroid was filled with 15MBq of 99mTc through two upper filling valves. Sealed micro-tubes (0.2ml) have been employed to simulate SLNs containing various 99mTc activity concentrations ranging between 0.1MBq and 1MBq, and can be positioned at any desired place in the head and neck region. An active background was simulated through mixing 10MBq of 99mTc solution with the water used to fill the outer shell of the head and neck phantom. Results: The head and neck phantom was employed to simulate a situation where there are four SLNs distributed at two different vertical levels and at two depths within the neck. Contrast to noise ratio (CNR) calculations were performed for the detected SLNs at an 80mm distance between both pinhole collimators (i.e. 0.5mm and 1.0mm diameters) and the surface of the head and neck phantom with a 100s acquisition time. The recorded CNR values for the simulated SLNs are higher when the HGC was fitted with the 1.0mm diameter pinhole collimator. For instance, the recorded CNR values for the superficially simulated SLN containing 0.1MBq of 99mTc using 0.5mm and 1.0mm diameter pinhole collimators are 6.48 and 16.42, respectively (~87% difference). The anatomical context provided by the hybrid imaging aided the localization process of radioactivity accumulation in simulated SLNs. Gamma and hybrid optical images were acquired using the HGC with both available pinhole collimators for the simulated thyroid gland. The thyroid images produced varied in terms of spatial resolution and detectability. The count profiles through the middle of the simulated thyroid gland images provided by both pinhole collimators were obtained. The HGC could clearly differentiate the individual peaks of both thyroid lobes in the gamma image produced by the 0.5mm pinhole collimator. In contrast, the recorded count profile for the acquired image using the 1.0mm diameter pinhole collimator showed broader peaks for both lobes, reflecting the degradation of the spatial resolution with increasing the diameter of the pinhole collimator. Conclusion: The capability of the HGC has been evaluated utilizing a prototype anthropomorphic head and neck phantom, and the gamma and hybrid images obtained demonstrate that it is ideally suited for intraoperative SLNs detection and small organ imaging. The standardization of test phantoms and protocols for SFOV portable gamma systems will provide an opportunity to collect data across various medical centers and research groups. Moreover, it will provide a technical baseline for researchers and clinical practitioners to consider when assessing their SFOV gamma imaging systems. The anthropomorphic head and neck phantom described is cost effective, reproducible, flexible and anatomically representative.
Objective(s): The aims of present study to findout the effect of aeromedical evacuation program on flight medics’ knowledge.
Methods: A pre-experimental design is carried in army aviation bases in Iraq, for the period of April 1st 2019 to October 25th 2019. Non-probability "purposive" sample of (30) flight medics are selected from army aviation bases. The questionnaire consisted of two main parts: the demographic characteristics of air paramedics, and the second part included five axes, which are (50) paragraphs related to the knowledge of air paramedics towards emergency injuries. The researcher used the statistical program version 20 to analyze the data, and the stability of the questionnaire was measured through the pre and post
The study aimed to detect the VrPIP2;7 gene using PCR approach, as well as to know the effect of the treatment with four increased melatonin concentrations of 50, 100, 150 and 200 ppm in addition to control treatment were 0 ppm on the gene expression of plasma membrane intrinsic proteins (PIP) genes in Vigna radiata L. plant exhibition for five periods of drought which is irrigation every 24 hours, 48 hours, 5 days, 10 days and every 15 days. The electrophoresis of agarose gel at a concentration of 2% showed one band when detecting the VrPIP2;7 gene with a sizeable 732 bp and using the 100 bp volume index. This gene was selected for sequencing study based on its importance as well as on the results of its gene expression. The sequencing of
... Show MoreAn observational study to discover the common conditions affecting the lumbosacral region that may affect lumbosacral position and tension. All the patients, underwent MRI exaamination (magnetic resonance imaging) in the supine position, were examined by the same consultant radiologist. The article was revised by the institutional ethical approval committee. The position of the nerve roots was observed, and the number of nerve roots was calculated anterior to a line passing between the mid-transvers process of L3(third lumbar vertebra). The number of nerve roots ahead of this line was calculated by the radiologist at the level of the right intervertebral foramen and at the left one. This procedure was applied to the normal group, an
... Show MoreThe research aims to measure the relationship and the impact of knowledge management processes to achieve the performance of insurance service, as well as analysis of the reality of the National Insurance Company to identify the level of overall performance, and to achieve this goal, it has been the selection of knowledge management processes according to the survey prepared a supplement to the study (Qubaisi, 2002), and of the four operations (knowledge generation, and storage of knowledge, and the distribution of knowledge, and application of knowledge), which represented the independent variable, and the performance has been the use of quantitative and qualitative measures, (sales growth, customer satisfaction), which represented the
... Show MoreIn this work, an enhanced Photonic Crystal Fiber (PCF) based on Surface Plasmon Resonance (SPR) sensor using a sided polished structure for the detection of toxic ions Arsenic in water was designed and implemented. The SPR curve can be obtained by polishing the side of the PCF after coating the Au film on the side of the polished area, the SPR curve can be obtained. The proposed sensor has a clear SPR effect, according to the findings of the experiments. The estimated signal to Noise Ratio (SNR), sensitivity (S), resolution (R), and Figures of merit (FOM) are approaching; the SNR is 0.0125, S is 11.11 μm/RIU, the resolution is 1.8x〖10〗^(-4), and the FOM is 13.88 for Single-mode Fiber- Photonic Crystal Fiber- single mode Fiber (SMF-P
... Show MoreBackground: Marginal adaptation is critical for long – term success of crown and bridge restoration. Computer aided design / computer aided manufacture (CAD/ CAM) system is gaining more importance in the fabrication of dental restoration. Objective: The aim of this study is to evaluate the effect of crystallization firing on the vertical marginal gap of IPS. emax CAD crowns which fabricated with two different CAD/CAM systems .Materials and Methods: Twenty IPS e.max CAD crowns were fabricated. We had two major groups (A, B) (10 crowns for each group) according to the CAD/CAM system being used: Group A: fabricated with Imes - Icore CAD/CAM system; Group B: fabricated with In Lab Sirona CAD/CAM system. Each group was subdivided into two s
... Show More