Objectives: Small field of view gamma detection and imaging technologies for monitoring in vivo tracer uptake are rapidly expanding and being introduced for bed-side imaging and image guided surgical procedures. The Hybrid Gamma Camera (HGC) has been developed to enhance the localization of targeted radiopharmaceuticals during surgical procedures; for example in sentinel lymph node (SLN) biopsies and for bed-side imaging in procedures such as lacrimal drainage imaging and thyroid scanning. In this study, a prototype anthropomorphic head and neck phantom has been designed, constructed, and evaluated using representative modelled medical scenarios to study the capability of the HGC to detect SLNs and image small organs. Methods: An anthropomorphic head and neck phantom has been designed to mimic the adult head and neck including some internal organs and tissues of interest, such as the thyroid gland and sentinel lymph nodes. The design of the head and neck phantom included an adjustable inner jig holding the simulated SLNs and thyroid gland. The simulated thyroid gland was designed and 3D printed taking into consideration the size and the shape of a healthy adult thyroid gland. The inner sealed space of the thyroid was filled with 15MBq of 99mTc through two upper filling valves. Sealed micro-tubes (0.2ml) have been employed to simulate SLNs containing various 99mTc activity concentrations ranging between 0.1MBq and 1MBq, and can be positioned at any desired place in the head and neck region. An active background was simulated through mixing 10MBq of 99mTc solution with the water used to fill the outer shell of the head and neck phantom. Results: The head and neck phantom was employed to simulate a situation where there are four SLNs distributed at two different vertical levels and at two depths within the neck. Contrast to noise ratio (CNR) calculations were performed for the detected SLNs at an 80mm distance between both pinhole collimators (i.e. 0.5mm and 1.0mm diameters) and the surface of the head and neck phantom with a 100s acquisition time. The recorded CNR values for the simulated SLNs are higher when the HGC was fitted with the 1.0mm diameter pinhole collimator. For instance, the recorded CNR values for the superficially simulated SLN containing 0.1MBq of 99mTc using 0.5mm and 1.0mm diameter pinhole collimators are 6.48 and 16.42, respectively (~87% difference). The anatomical context provided by the hybrid imaging aided the localization process of radioactivity accumulation in simulated SLNs. Gamma and hybrid optical images were acquired using the HGC with both available pinhole collimators for the simulated thyroid gland. The thyroid images produced varied in terms of spatial resolution and detectability. The count profiles through the middle of the simulated thyroid gland images provided by both pinhole collimators were obtained. The HGC could clearly differentiate the individual peaks of both thyroid lobes in the gamma image produced by the 0.5mm pinhole collimator. In contrast, the recorded count profile for the acquired image using the 1.0mm diameter pinhole collimator showed broader peaks for both lobes, reflecting the degradation of the spatial resolution with increasing the diameter of the pinhole collimator. Conclusion: The capability of the HGC has been evaluated utilizing a prototype anthropomorphic head and neck phantom, and the gamma and hybrid images obtained demonstrate that it is ideally suited for intraoperative SLNs detection and small organ imaging. The standardization of test phantoms and protocols for SFOV portable gamma systems will provide an opportunity to collect data across various medical centers and research groups. Moreover, it will provide a technical baseline for researchers and clinical practitioners to consider when assessing their SFOV gamma imaging systems. The anthropomorphic head and neck phantom described is cost effective, reproducible, flexible and anatomically representative.
The purpose of this study is to investigate the research on artificial intelligence algorithms in football, specifically in relation to player performance prediction and injury prevention. To accomplish this goal, scholarly resources including Google Scholar, ResearchGate, Springer, and Scopus were used to provide a systematic examination of research done during the last ten years (2015–2025). Through a systematic procedure that included data collection, study selection based on predetermined criteria, categorisation based on AI applications in football, and assessment of major research problems, trends, and prospects, almost fifty papers were found and analysed. Summarising AI applications in football for performance and injury p
... Show Morewind load coefficient
This study utilizes streamline simulation to model fluid flow in the complex subsurface environment of the Mishrif reservoir in Iraq's Buzurgan oil field. The reservoir faces challenges from high-pressure depletion and a substantial increase in water cut during production, prompting the need for innovative reservoir management. The primary focus is on optimizing water injection procedures to reduce water cuts and enhance overall reservoir performance. Three waterflooding tactics were examined: normal conditions without injectors or producers, normal conditions with 30 injectors and 80 producers and streamline simulation using the frontsim simulator. Three main strategies were employed to streamline water injection in targeted areas.
... Show Moreract
This reaserch seeks To answer Wondering :(Is there a possibility employ strategic agility In companies sample Serving in Iraq ?)
This reaserch aims: explore Strategic Agility rely upon Dimensions that interact with each other to form the intcllectual frame Strategic Agility, These dimensions are: (Clarity of vision, Selected
... Show MoreFocusing of Gaussian laser beam through nonlinear media can induce spatial self- phase modulation which forms a far field intensity pattern of concentric rings. The nonlinear refractive index change of material depends on the number of pattern rings. In this paper, a formation of tunable nonlinear refractive index change of hybrid functionalized carbon nanotubes/silver nanoparticles acetone suspensions (F-MWCNTs/Ag-NPs) at weight mixing ratio of 1:3 and volume fraction of 6x10-6 , 9x10-6 , and 18x10-6 using laser beam at wavelength of 473nm was investigated experimentally. The results showed that tunable nonlinear refractive indices were obtained and increasing of incident laser power density led to increase the nonlinear refractive inde
... Show MoreIn this paper, Pentacene based-organic field effect transistors (OFETs) by using different layers (monolayer, bilayer and trilayer) for three different gate insulators (ZrO2, PVA and CYEPL) were studied its current–voltage (I-V) characteristics by using the gradual-channel approximation model. The device exhibits a typical output curve of a field-effect transistor (FET). Source-drain voltage (Vds) was also investigated to study the effects of gate dielectric on electrical performance for OFET. The effect of capacitancesemiconductor in performance OFETs was considered. The values of current and transconductance which calculated using MATLAB simulation. It exhibited a value of current increase with increasing source-drain voltage.
In this paper, Pentacene based-organic field effect transistors (OFETs) by using different layers (monolayer, bilayer and trilayer) for three different gate insulators (ZrO2, PVA and CYEPL) were studied its current–voltage (I-V) characteristics by using the gradual-channel approximation model. The device exhibits a typical output curve of a field-effect transistor (FET). Source-drain voltage (Vds) was also investigated to study the effects of gate dielectric on electrical performance for OFET. The effect of capacitance semiconductor in performance OFETs was considered. The values of current and transconductance which calculated using MATLAB simulation. It exhibited a value of current increase with increasing source-drain voltage.
In recent years, there has been a significant increase in research demonstrating the new and diverse uses of non-thermal food processing technologies, including more efficient mixing and blending processes, faster energy and mass transfer, lower temperature and selective extraction, reduced thermal and concentration gradients, reduced equipment size, faster response to extraction control, faster start-up, increased production, and a reduction in the number of steps in preparation and processing. Applications of ultrasound technology have indicated that this technology has a promising and significant future in the food industry and preservation, and there is a wide scope for its use due to the higher purity of final products and the
... Show More