In aired and semiarid areas like Iraq, saline soil may be considered one of the major concerns. In addition to environmental effects, they may produce significant geotechnical hazards that could interrupt the structure stability depending on the salt type and its concentration. So, it is crucial to identify the degree of the soil salinity with a proper tool for getting a qualified assessment and consequently offering a suitable treatment. In this paper, the electrical resistivity technique has been employed to detect the degree of soil salinity by considering a new electronic system. The system used a single-phase Direct Current (DC) to Alternating Current (AC) inverter accompanied by a transformer. Natural soils became artificially saline after mixing with different brines including sodium chloride, magnesium chloride, calcium chloride, and sodium silicate. Each salt was added to the pure water at low percentages varying from 0% to 10% and mixed with the dry soil. The mixture was compacted and transferred to a self-developed pre-calibrated cylindrical resistivity cell of four steel electrodes. Afterward, electrical resistivity measurements were taken using the electronic component and personal computer, and the corresponding results are discussed and analyzed. Results show that an electrical resistivity method is a good tool for detecting soil salinity, and the adopted electronic device for measuring soil resistivity differentiates the resistivity values such that the measurements are very sensitive to the salt type and concentration, and which was so pronounced when adding low percentages of salt.
The research aims to prepare special exercises according to specific areas in the accuracy of performing the reverse low blow for squash players, and to identify the effect of special exercises according to specific areas in the accuracy of performing the reverse low blow for squash players. To achieve the goal, the researchers used the experimental method by designing the experimental and control groups with pre- and post-tests to suit it with the research problem. The research population was chosen intentionally, and they are junior squash players aged (13-15) years, who number (12 junior players), as the research sample constituted (100%). ) From the research community, they were chosen intentionally because there were no other p
... Show MoreThe variation of compression index Cc and swelling index Cs with the degree of saturation S was studied on unsaturated and fully saturated soils for different degrees of saturation (100%, 91%, 85%, 75%, 60%), several mathematical equations were found to describe these relationships, these equations can be used to predict settlement during the consolidation process in unsaturated and fully saturated soils.
Flow-production systems whose pieces are connected in a row may not have maintenance scheduling procedures fixed because problems occur at different times (electricity plants, cement plants, water desalination plants). Contemporary software and artificial intelligence (AI) technologies are used to fulfill the research objectives by developing a predictive maintenance program. The data of the fifth thermal unit of the power station for the electricity of Al Dora/Baghdad are used in this study. Three stages of research were conducted. First, missing data without temporal sequences were processed. The data were filled using time series hour after hour and the times were filled as system working hours, making the volume of the data relativel
... Show MoreThis paper presents a robust algorithm for the assessment of risk priority for medical equipment based on the calculation of static and dynamic risk factors and Kohnen Self Organization Maps (SOM). Four risk parameters have been calculated for 345 medical devices in two general hospitals in Baghdad. Static risk factor components (equipment function and physical risk) and dynamics risk components (maintenance requirements and risk points) have been calculated. These risk components are used as an input to the unsupervised Kohonen self organization maps. The accuracy of the network was found to be equal to 98% for the proposed system. We conclude that the proposed model gives fast and accurate assessment for risk priority and it works as p
... Show MoreIn the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the
... Show MoreThe experiment was aimed to evaluate a locally manufactured a dual-action device used for measuring feed pellets durability. The device performs dropping process in conventional devices, then sifting process to separate the pellets from the crumbles simultaneously, with a control the motor speed by using the pulse width modulation (PWM) Technique. The device performance was compared with the durability measuring device of a moving drop box. Rotational speed, diameter of the die holes of the machine was used in this study. The results showed that increasing the rotational speed of the die from 280 to 300 and to 320 rpm, increasing the die holes diameter from 3 to 4 and to 5 mm, led to