Preferred Language
Articles
/
uhblcosBVTCNdQwCR8vZ
Modified ZnO for efficient photo-catalysis by Silver/Graphite oxide nanoparticles
...Show More Authors

Scopus
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Schultz and Modified Schultz Polynomials for Edge – Identification Chain and Ring – for Square Graphs
...Show More Authors

In a connected graph , the distance function between each pair of two vertices from a set vertex  is the shortest distance between them and the vertex degree  denoted by  is the number of edges which are incident to the vertex  The Schultz and modified Schultz polynomials of  are have defined as:

 respectively, where the summations are taken over all unordered pairs of distinct vertices in  and  is the distance between  and  in  The general forms of Schultz and modified Schultz polynomials shall be found and indices of the edge – identification chain and ring – square graphs in the present work.

View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Physics: Conference Series
A modified ARIMA model for forecasting chemical sales in the USA
...Show More Authors
Abstract<p>model is derived, and the methodology is given in detail. The model is constructed depending on some measurement criteria, Akaike and Bayesian information criterion. For the new time series model, a new algorithm has been generated. The forecasting process, one and two steps ahead, is discussed in detail. Some exploratory data analysis is given in the beginning. The best model is selected based on some criteria; it is compared with some naïve models. The modified model is applied to a monthly chemical sales dataset (January 1992 to Dec 2019), where the dataset in this work has been downloaded from the United States of America census (www.census.gov). Ultimately, the forecasted sales </p> ... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Sat May 24 2025
Journal Name
Iraqi Journal For Computer Science And Mathematics
Intrusion Detection System for IoT Based on Modified Random Forest Algorithm
...Show More Authors

An intrusion detection system (IDS) is key to having a comprehensive cybersecurity solution against any attack, and artificial intelligence techniques have been combined with all the features of the IoT to improve security. In response to this, in this research, an IDS technique driven by a modified random forest algorithm has been formulated to improve the system for IoT. To this end, the target is made as one-hot encoding, bootstrapping with less redundancy, adding a hybrid features selection method into the random forest algorithm, and modifying the ranking stage in the random forest algorithm. Furthermore, three datasets have been used in this research, IoTID20, UNSW-NB15, and IoT-23. The results are compared with the three datasets men

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (9)
Scopus Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Optik
Synthesis and characterization of PVDF/PMMA/ZnO hybrid nanocomposite thin films for humidity sensor application
...Show More Authors

View Publication
Scopus (36)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Experimental Study of Spatial Self-Phase Modulation (SSPM) Based on Laser Beam and Hybrid Functionalized Carbon Nanotubes/Silver Nanoparticles (F-Mwcnts/Ag-Nps) Acetone Suspensions
...Show More Authors

Focusing of Gaussian laser beam through nonlinear media can induce spatial self- phase modulation which forms a far field intensity pattern of concentric rings. The nonlinear refractive index change of material depends on the number of pattern rings. In this paper, a formation of tunable nonlinear refractive index change of hybrid functionalized carbon nanotubes/silver nanoparticles acetone suspensions (F-MWCNTs/Ag-NPs) at weight mixing ratio of 1:3 and volume fraction of 6x10-6 , 9x10-6 , and 18x10-6 using laser beam at wavelength of 473nm was investigated experimentally. The results showed that tunable nonlinear refractive indices were obtained and increasing of incident laser power density led to increase the nonlinear refractive inde

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 07 2016
Journal Name
International Journal Of Scientific & Engineering Research
Fast Response Photoconductive for Fe3O4:Ce Nanoparticles
...Show More Authors

Fe3O4:Ce thin films were deposited on glass and Si substrates by Pulse Laser Deposition Technique (PLD). Polycrystalline nature of the cubic structure with the preferred orientation of (311) are proved by X-ray diffraction. The nano size of the prepared films are revealed by SEM measurement. Undoped Iron oxide and doped with different concentration of Ce films have direct allowed transition band gap with 2.15±0.1 eV which is confirmed by PL Photoluminescence measurements. The PL spectra consist of the emission band located at two sets of peaks, set (A) at 579±2 nm , and set (B) at 650 nm, respectively when it is excited at an excitation wavelength of 280 nm at room temperature. I-V characteristics have been studied in the dark and under v

... Show More
Publication Date
Fri Aug 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Sub–Nyquist Frequency Efficient Audio Compression
...Show More Authors

This paper presents the application of a framework of fast and efficient compressive sampling based on the concept of random sampling of sparse Audio signal. It provides four important features. (i) It is universal with a variety of sparse signals. (ii) The number of measurements required for exact reconstruction is nearly optimal and much less then the sampling frequency and below the Nyquist frequency. (iii) It has very low complexity and fast computation. (iv) It is developed on the provable mathematical model from which we are able to quantify trade-offs among streaming capability, computation/memory requirement and quality of reconstruction of the audio signal. Compressed sensing CS is an attractive compression scheme due to its uni

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2007
Journal Name
Atti Della “fondazione Giorgio Ronchi”
Photo-physical characterization of Rhodamine B in liquid and solid solutions
...Show More Authors

SUMMARY. – Absorption, flourescence, quantum yield and lifetime of rhodamine B in chloroform, methanol and dimethyl sulfoxide were measured. A comparison was done of these quantities with those for solid solutions, which are obtained by mixing constant volume proportions of dye at a concentration of 1×10–4M/l with different volume proportions from the concentrated solution of polymer in chloroform and dimethyl sulfoxide. The results showed that the addition of polymer to liquid concentrated solutions (1×10–4M/l) of rhodamine B dye from expecting, which leads to development of active medium for laser dye at high concentration, increase the spectra shift toward high energies, and the luminescence quantum yield but decreasing radiative

... Show More
Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Materials Science For Energy Technologies
New organic PVC photo-stabilizers derived from synthesised novel coumarine moieties
...Show More Authors

View Publication
Scopus (23)
Crossref (5)
Scopus Crossref
Publication Date
Sat Feb 22 2020
Journal Name
Radiation And Environmental Biophysics
The photo-transferred thermoluminescence phenomenon in case of emergency dose assessment
...Show More Authors
Abstract<p>A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For</p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref