Preferred Language
Articles
/
uRjVWpQBVTCNdQwCdQVv
Theoretical modeling study on preparation of nanosized drugs using supercritical-based processing: Determination of solubility of Chlorothiazide in supercritical carbon dioxide
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Oct 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Theoretical Calculation of The Fill Factor of N749/〖TiO〗_2 Solar Cells
...Show More Authors

        In this paper, the fill factor of the N749/TiO2 solar cell is studied and calculated using the analysis method at standard conditions; i.e., T=300k  and  100 mW/cm2 irradiation.. The current density was derived and calculated using the donor-acceptor model according to the quantum transfer theory in DSSC solar cells. We estimate the influence parameters in DSSC that's an equivalent circuit to the I-V curves for three solvents. The fill factor parameters of the N749/TiO2 device are found to be 0.137,0.146 and 0.127 with Butanol, Ethanol           and Acetonitrile for carrier concentration .  1018 1/cm3 respectively. The photovoltaic characteristics ISc  , Vco<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 18 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Theoretical Investigation of Enhanced Thermoelectric Figure of Merit of Low-Dimensional Structures
...Show More Authors

 The power factors and electronic thermal conductivities in bismuth telluride (Bi2Te3), lead-telluride (PbTe), and gallium arsenide (GaAs) at room temperature (300K) quantum wires and quantum wells are theoretically investigated. Our formalism rigorously takes into account modification of these power factors and electronic thermal conductivities in free-surface wires and wells due to spatial confinement. From our numerical results, we predict a significant increase of the power factor in quantum wires with diameter w=20 Ã…. The increase is always stronger in quantum wires than in quantum wells of the corresponding dimensions. An unconfined phonon distribution assumed based on the bulk lattice thermal conductivity is then employed

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 25 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetry and Indirect X-ray Fluorescence Determination of Active Ingredients in Tetracycline Hydrochloride Drug and Injection Solution of B12 Vitamin Using of Polyurethane Foam Sorbents
...Show More Authors

The simple and available technique of colorimetry and indirect X-ray fluorescence determination of tetracycline hydrochloride (in the form of colored complex with iron(III) ions) and cyanocobalamine (in the form of the colored thiocyanate complex with cobalt(II) ions) is offered. The analytes were separated from the accompanying components by sorption to polyurethane foam based on ethers. The conditions of sorption separation and measurement of analytical signal of these substances are optimized. The obtained results of tetracycline drugs and injection solution B12 vitamin are in satisfactory agreement with data declared by the manufacturer.

View Publication Preview PDF
Crossref
Publication Date
Wed May 25 2022
Journal Name
Iraqi Journal Of Science
Metal Complexes of Bis (2,6-diamine pyridine 2,5-hexanedione) Macrocyclic Schiff-Base Ligand: Preparation, Characterization and thermal study
...Show More Authors

     New series of Schiff base macrocyclic complexes have been prepared through a new chemical approach. Firstly, ligand Bis (2,6-diamine pyridine 2,5-hexanedione (DP-HD)  prepared via reacting of 2,6-diamine pyridine (DP) with 2,5-hexanedione(HD) in molar ration (1DP:1HD). The complexes of this ligand include Mn (II), Fe (II), Co (II), Ni (II) and Cu (II) as central metal ions also prepared with a molar ratio of (1 ligand:1 metal ion). Metals chloride was used as raw materials for this preparation. A variety of spectral and physical techniques were applied to characterize the macrocyclic complexes such as 1H-NMR, FT-IR, UV-Vis, CHN analysis, conductivity, Atomic absorption and magnetic susceptibility. Depending on spectral and magn

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of the theoretical framework of the REA accounting model Used in the design of accounting information systems
...Show More Authors

Researchers often equate database accounting models in general and the Resources-Events-Agents (REA) accounting model in particular with events accounting as proposed by Sorter (1969). In fact, REA accounting, database accounting, and events accounting are very different. Because REA accounting has become a popular topic in AIS research, it is important to agree on exactly what is meant by certain ideas, both in concept and in historical origin. This article clarifies the analyzing framework of REA accounting model and highlights the differences between the terms events accounting, database accounting, semantically-modeled accounting, and REA accounting. It als

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Study Analytical of The Effect Magnesium ion Concentration to Determination the Total Hardness And Comparison Spectrophotometry
...Show More Authors

The determination hardness in water raised to rivers caused several problem in the validity of the water used depends on where determination ions concentration calcium and magnesium in salts carbonate and sulfate , this possibility of separation between of these ions and the resulting impact on concentration and determination the degree of hardness water and appreciation between the insolvent water quality . It study the effect of the impact of concentration magnesium ion in determination the quality of the water has turned out to be Mg concentration more than 60% of the total content of hardness is borderline in hardness effect the determination. Adopted in this research determination the ions in two method titration by EDTA solution and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Determination of the Shape and Dimensions of the Sensitive Volume for Solid State Detectors Using Monte Carlo Computer Technique
...Show More Authors

In this research the active volume for a number of solid-state detectors of the type of high-purity germanium (HPGe) crystal was evaluated with different radii and depths using scanning method for diagonal (front) and lateral (side). It has been used for this purpose Monte-Carlo efficiency program after its development by adding a subroutine-program for its (subroutine scanning).Also a program has been written to calculate the stopping power and range for incident charged particle on the detector, in order to determine the exact sufficient energy to stop it inside the detector material. The calculations of our results of efficiency were compared with the results of published efficiency and the comparison is very good in terms of improvin

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Determination of oxonium ion and application via quenching of continuous fluorescence light (fluorescein salt) using I- -IO3--H3O+ system
...Show More Authors

The research work present a sensitive, accurate and fast developed for the determination of oxonium ion (HCl, H2SO4 , HClO4 and tartaric acid). It relies on the formation free iodine molecule from the I--IO3--H3O+ reaction which react with fluorescein sodium salt solution causing to quench the fluorescence light (continuous fluorescence) when irradiated by laser source at 405nm. Optimum parameters were studied giving to specify the chemical and physical parameters. Two line manifold was used. The flow rate of 1.3 and 1.5 mL/min was used, 35μL sample volume no.1 and sample volume no.2 , linear dynamic range extend from 0.05-7, 0.05-7, 0.1-10 and 0.1-10 mMol.l-1 with correlation coefficient of 0.9933, 0.9964, 0.9984 and 0.9973 for HCl, H2

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 24 2022
Journal Name
Journal Of Educational And Psychological Researches
The Effect of using Project - Based Learning method in development intensive reading skills at middle school students
...Show More Authors

The purpose of this research is to identify the effect of the use of project-based learning in the development of intensive reading skills at middle school students. The experimental design was chosen from one group to suit the nature of the research and its objectives. The research group consisted of 35 students. For the purpose of the research, the following materials and tools were prepared: (List of intensive reading skills, intensive reading skills test, teacher's guide, student book). The results of the study showed that there were statistically significant differences at (0.05) in favor of the post-test performance of intensive reading skills. The statistical analysis also showed that the project-based learning approach has a high

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.: SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.
...Show More Authors

Two molecular imprinted polymer (MIP) membranes for Levofloxacin (LEV) were prepared based on PVC matrix. The imprinted polymers were prepared by polymerization of styrene (STY) as monomer, N,N methylene di acrylamide as a cross linker ,benzoyl peroxide (BPO) as an initiator and levofloxacin as a template. Di methyl adepate (DMA) and acetophenone (AOPH) were used as plasticizers , the molecular imprinted membranes and the non molecular imprinted membranes were prepared.  The slopes and detection limits of the liquid electrodes ranged from -21.96 – -19.38 mV/decade and 2×10-4M- 4×10-4M, and Its response time was around 1 minute, respectively. The liquid  electrodes were packed with 0.1 M standar

... Show More
View Publication Preview PDF