Preferred Language
Articles
/
uBd7MI8BVTCNdQwCl19h
Cleaning efficacy and instrumentation time using rotary file system in primary molars (comparative study)
...Show More Authors

ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to access opening and then all the canals injected with Indian ink. Then, 48 hours later, the teeth were randomly classified into two groups: group A (n=fifteen tooth): where the manual preparation of the root canals was done by stainless steel K- files, while group B (n= fifteen tooth): consisted of the root canals that prepared with rotary two shape system. The total instrumentation time was measured using a digital stopwatch. After that, a disk bur was used to section the roots. Then, a digital camera was used to photograph the specimens to evaluate the root canal cleaning. The cleaning efficacy was compared at the coronal, middle and apical level. In the coronal third, rotary two shape system showed more removal to the ink than the K-file with statistical significant difference (p <0.05), however, for the middle third of the canal, no statistical difference was found between the two systems (p=0.05). While at the apical level, K-file showed more removal to the ink than the rotary two shape system and with statistical significant difference (p <0.05). Evaluation of the total samples revealed no statistical significant difference concerning the efficacy of cleaning between K-files and rotary two shape system files. The group that was rotary prepared took less time for the canal preparation as compared to the manual group (80.063 sec., 144.576 sec. respectively). No significant difference was found between the two systems concerning the cleaning efficacy. Instrumentation done by the rotary system took significantly less time than that of the manual. KEYWORDS: Cleaning efficacy, manual instrumentation, primary teeth, rotary instrumentation.

Publication Date
Wed Mar 15 2023
Journal Name
Al-academy
The Self-Efficacy Level Among Musically Talented Students
...Show More Authors

This Study Aimed to Recognize the Self-Efficacy Level Among Musically Talented Students the sample of this study consisted of (85) Musically smart students male and female students in Irbid governorate, of the analytical descriptive method ، and the Self-Efficacy scale were used, and the results indicated the following:
-The Self-Efficacy level among Musically smart students was high.
-There are no statistically significant differences (α ≥ 0.05)due to the impact of gender in a the total degree .
-There are no statistically significant differences (α=0.05) due to the impact of stage in a the total degree.

View Publication Preview PDF
Crossref
Publication Date
Wed Feb 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Supra-Approximation Spaces Using Mixed Degree System in Graph Theory
...Show More Authors

This paper is concerned with introducing and studying the o-space by using out degree system (resp. i-space by using in degree system) which are the core concept in this paper. In addition, the m-lower approximations, the m-upper approximations and ospace and i-space. Furthermore, we introduce near supraopen (near supraclosed) d. g.'s. Finally, the supra-lower approximation, supraupper approximation, supra-accuracy are defined and some of its properties are investigated.

Publication Date
Mon Apr 03 2023
Journal Name
Journal Of Educational And Psychological Researches
The Role of Digital Repositories in Developing Teacher Performance in the Primary Stage
...Show More Authors

Abstract

Digital repositories are considered one of the integrated collaborative educational environments that help every researcher interested in developing the education and educational process. The learning resources provided by the repositories are suitable for every researcher, so digital information can be stored and exchanged by ensuring the participation and cooperation of researchers, teachers, and those who are interested, as well as curricula experts, teachers, and students, to exchange each other’s experiences in constantly updating that information as a reason for developing their performance in education. This reveals the importance of the role of educational digital institutions by providing and

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 09 2021
Journal Name
Design Engineering
The Impact of Transforming the Educational System in Iraq from 6-3-3 to 4-4-4 on Educational Planning Standards and the Deficiency of School Buildings (Primary and Secondary Education)
...Show More Authors

&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Educational services in Iraq face many problems that have reduced the efficiency of the educational process, as a result of the difficult conditions experienced by educational services in Iraq. This led to the accumulation of these problems and their exacerbation significantly over the years, as there was no fundamental solution to these problems. The study proposes a planning method for managing the educational system in Iraq, especially for the primary and secondary levels, where these negative phenomena are very prominent, especially the deficit in school buildings and the phenomenon of overcrowding in classrooms. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&am

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 30 2024
Journal Name
South Eastern European Journal Of Public Health
Antimicrobial Efficacy of a Novel Herbal Endodontic Irrigant Against Enterococcus Faecalis in Root Canals of Permanent Teeth: An in Vitro Study
...Show More Authors

Background: A successful endodontic treatment is aimed at the sterilization of the entire pulp space. The use of extracts from Rhamnus prinoides as a novel irrigating material for root canal has not been studied . Hence, the antimicrobial efficacy of the alcoholic extract of Rhamnus prinoides as an irrigation material against E. faecalis was evaluated in comparison with the 2.5% sodium hypochlorite (NaOCL) solution used for root canals of permanent teeth. Methods: A total of 30 single-rooted human permanent teeth were thoroughly cleaned, shaped, and disinfected. Then, each tooth was subjected to a two-week infection with Enterococcus faecalis at 37 °C . Afterward, the samples were divided into three groups (10 teeth per group): 0.9

... Show More
View Publication
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars
...Show More Authors

Evaluation of the Serum Level of Interleukin-6 in Patients Undergoing Surgical Removal of Impacted Mandibular Third Molars, Hussain A Taher*, Salwan Y Bede

View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
A comparative Study to calculate the Runs Property in the encryption systems
...Show More Authors

Cryptographic applications demand much more of a pseudo-random-sequence
generator than do most other applications. Cryptographic randomness does not mean just
statistical randomness, although that is part of it. For a sequence to be cryptographically
secure pseudo-random, it must be unpredictable.
The random sequences should satisfy the basic randomness postulates; one of them is
the run postulate (sequences of the same bit). These sequences should have about the same
number of ones and zeros, about half the runs should be of length one, one quarter of length
two, one eighth of length three, and so on.The distribution of run lengths for zeros and ones
should be the same. These properties can be measured determinis

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 03 2019
Journal Name
Rawal Medical Journal
SUPERIOR VERSUS ANTERIOR PLATING OF MIDSHAFT CLAVICLE FRACTURE IN ADULT COMPARATIVE STUDY
...Show More Authors

Clavicle fractures are common injuries in young, active individuals. The majority of the fractures (80% to 85%) occur in the mid-shaft of the bone and account for approximately 2.6% of all fractures. For many years the standard treatment of fracture clavicle was the "figure-of-eight" bandage but several indications for operative fixation, the position of plate fixation for clavicle fracture remains controversial. The aim of this study is to compare between anterio—inferior and anterior-superior plating of mid-shaft displaced clavicle fracture in complications, plate prominence, nonunion, malunion and range of motion. This study is a prospective study conducted in Al-Kindy teaching hospital .A total of 30 patients with fracture mid –sh

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 29 2022
Journal Name
Research Journal Of Pharmacy And Technology
Rifampicin versus Doxycycline in Prevention of recurrent Boils (A Comparative Therapeutic Study)
...Show More Authors

Background: Suffering from recurrent boils (furunclosis) is a common problem in our locality as it is noticed by many dermatologists especially in association with increasingly hot weather. The most common causative organisms are staphylococci. Objective: The aim of the study was to shed the light upon this problem and compare two systemic therapeutic agents for the prevention of recurrence, doxycycline and rifampicin. Patient and method: One hundred thirty-five (135) Patients with recurrent boils from Al-Yarmouk teaching hospital dermatology outpatient department were included in this study; age ranged from 10 to 64 years old and out of total patients 32 were males and 103 were females. Patients were assessed by full history and cl

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Oct 04 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An in-vitro scan electron microscope comparative study of dentine-Biodentine interface
...Show More Authors

Background: Restoration of the gingival margin of Class II cavities with composite resin continues to be problematic, especially where no enamel exists for bonding to the gingival margin. The aim of study is to evaluate the marginal leakage at enamel and cementum margin of class II MOD cavities using amalgam restoration and modern composite restorations Filtek™ P90, Filtek™ Z250 XT (Nano Hybrid Universal Restorative) and SDR bulk fill with different restoratives techniques. Materials and method: Eighty sound maxillary first premolar teeth were collected and divided into two main groups, enamel group and cementum group (40 teeth) for each group. The enamel group was prepared with standardized Class II MOD cavity with gingival margin (1 m

... Show More
View Publication Preview PDF