Preferred Language
Articles
/
uBd7MI8BVTCNdQwCl19h
Cleaning efficacy and instrumentation time using rotary file system in primary molars (comparative study)
...Show More Authors

ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to access opening and then all the canals injected with Indian ink. Then, 48 hours later, the teeth were randomly classified into two groups: group A (n=fifteen tooth): where the manual preparation of the root canals was done by stainless steel K- files, while group B (n= fifteen tooth): consisted of the root canals that prepared with rotary two shape system. The total instrumentation time was measured using a digital stopwatch. After that, a disk bur was used to section the roots. Then, a digital camera was used to photograph the specimens to evaluate the root canal cleaning. The cleaning efficacy was compared at the coronal, middle and apical level. In the coronal third, rotary two shape system showed more removal to the ink than the K-file with statistical significant difference (p <0.05), however, for the middle third of the canal, no statistical difference was found between the two systems (p=0.05). While at the apical level, K-file showed more removal to the ink than the rotary two shape system and with statistical significant difference (p <0.05). Evaluation of the total samples revealed no statistical significant difference concerning the efficacy of cleaning between K-files and rotary two shape system files. The group that was rotary prepared took less time for the canal preparation as compared to the manual group (80.063 sec., 144.576 sec. respectively). No significant difference was found between the two systems concerning the cleaning efficacy. Instrumentation done by the rotary system took significantly less time than that of the manual. KEYWORDS: Cleaning efficacy, manual instrumentation, primary teeth, rotary instrumentation.

Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Stomatology
The effectiveness of limited flap design in surgical removal of fully impacted lower third molars: a comparative clinical study
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Fri Jan 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of curvature angle and rotational speed on the cyclic fatigue of three types of rotary instrument (In vitro): comparative study
...Show More Authors

Background: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Wasit Journal Of Computer And Mathematics Science
Real time handwriting recognition system using CNN algorithms
...Show More Authors

Abstract— The growing use of digital technologies across various sectors and daily activities has made handwriting recognition a popular research topic. Despite the continued relevance of handwriting, people still require the conversion of handwritten copies into digital versions that can be stored and shared digitally. Handwriting recognition involves the computer's strength to identify and understand legible handwriting input data from various sources, including document, photo-graphs and others. Handwriting recognition pose a complexity challenge due to the diversity in handwriting styles among different individuals especially in real time applications. In this paper, an automatic system was designed to handwriting recognition

... Show More
View Publication
Crossref
Publication Date
Sat Jun 01 2019
Journal Name
2019 Ieee International Conference On Automatic Control And Intelligent Systems (i2cacis)
Study on Solar Panel Cleaning Robot
...Show More Authors

View Publication
Scopus (27)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
Comparative Study between RIPASA Scoring System and ALVARADO Scoring System in Diagnosing Acute Appendicitis in Adults
...Show More Authors

Background: Acute appendicitis is regarded as one of the most common inflammation that needs surgical intervention. Different scoring systems have been used for diagnosing of acute appendicitis. ALVARADO score is one of the most widely used score in diagnosing of acute appendicitis, but the accuracy of the latter is insufficiently low in Middle-East patients. Thus a new scoring system called RIPASA score has been designed for diagnosing of acute appendicitis in those patients. The aim of this study is to use RIPASA score and compare its result with ALVARADO score in diagnosing of acute appendicitis.

Subjects and Methods: The study includes 200 patients with symptoms and signs of

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Engineering And Technology Journal
Text File Hiding Randomly Using Secret Sharing Scheme
...Show More Authors

Exchange of information through the channels of communication can be unsafe. Communication media are not safe to send sensitive information so it is necessary to provide the protection of information from disclosure to unauthorized persons. This research presented the method to information security is done through information hiding into the cover image using a least significant bit (LSB) technique, where a text file is encrypted using a secret sharing scheme. Then, generating positions to hiding information in a random manner of cover image, which is difficult to predict hiding in the image-by-image analysis or statistical analyzes. Where it provides two levels of information security through encryption of a text file using the secret sha

... Show More
View Publication
Crossref
Publication Date
Fri Jan 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effects of unilateral premature loss of maxillary primary molars on the dental arch dimensions
...Show More Authors

Background: The aim of the study was to evaluate the amount of changes in the horizontal and vertical maxillary arch dimensions measurements following the premature loss of primary molars. Materials and methods: The sample consist of (50) children with unilateral prematurely extracted either first or second primary molars at the mixed dentition stage. Results and Conclusions: Results shows that there was an increase in the vertical incisor to canine distance (A) with both premature loss of first & second primary molars due to distal movement of primary canines and at the same time there were a significant loss of space in the extraction space with premature loss of second primary molar due to a mesial movement of maxillary first permanent

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 24 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Health Hazards, Hematological and Biochemical Alterations in Dry-Cleaning Workers using Perchloroethylene.
...Show More Authors

Perchloroethylene (PERC) is commonly used as a dry-cleaning solvent, it is attributed to many deleterious effects in the biological system. The study aimed to investigate the harmful effect associated with PERC exposure among dry-cleaning workers. The study was carried out on 58 adults in two groups. PERC-exposed group; include thirty-two male dry-cleaning workers using PERC as a dry-cleaning solvent and twenty-six healthy non-exposed subjects. History of PERC exposure, use of personal protection equipment (PPE), safety measurement of the exposed group was recorded. Blood sample was taken from each participant for measurement of hematological markers, liver and kidney function tests. The results showed that 28.1% of the workers were usin

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Oct 31 2018
Journal Name
Al-kindy College Medical Journal
Efficacy Of Hyaluronic Acid And Corticosteroid Intra-Articular Injection In Knee Joint With Primary Osteoarthritis
...Show More Authors

Background: Osteoarthritis OA is the most common joint disorder in the world. Injection of high molecular weight hyaluronic acid intra-articular with steroid is a one of the used therapeutic option for patients with (OA)knee.

Objectives: Objective of this study was the evaluation the efficacy, safety, pluse duration of action of viscosupplementation of the  HMWHA( high molecular weight hyluranic acid ).

Type of the study: Cross-sectional study.

Methods: From 81 patients with sever knee pain due to OA (grades 3–4) were recruited from Al-Yarmouk teaching hospital  & a private clinic during the period from January 2014 till July 2016.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparison of the Effectiveness of Reciprocating System with Continuous Rotary Systems in Non-Surgical Endodontic Retreatment (An In vitro study)
...Show More Authors

Background: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota

... Show More
View Publication Preview PDF
Crossref