Preferred Language
Articles
/
u0K-pZoBMeyNPGM3_M6c
Tetracycline removal from aqueous solution through photo-anodic oxidation process using rotating graphite cylinder anode
...Show More Authors

   In the present work, tetracycline (TC) was removed from a simulated wastewater through a new photo-anodic oxidation process with a rotating graphite cylinder anode. The effects of current density, pH, rotation speed, and NaCl addition were evaluated. The results confirmed that increasing the current density results in improving the removal of TC. However, increasing the current density beyond 5 mA/cm2 had little effect on TC removal. Results revealed that TC removal using photoanodic oxidation can be achieved at high performance with an initial pH of 5. Increasing or decreasing pH beyond this value has a negative effect on TC removal. Increasing rotation speed gave better performance for TC removal due to the increase in mass transfer. The addition of NaCl improved the removal efficiency of TC due to the participation of indirect anodic oxidation within the oxidation process. The best conditions were: current density of 5mA/cm2, pH=5, 250 rpm, and the addition of 1 g/L NaCl, in which TC removal of 84% was achieved that claims (103 kWh/m3) as a total electrical energy consumption. In comparison with the anodic oxidation process alone, photo-anodic improved TC removal by an increment of (13.73%), confirming the photo-anodic process can be adopted successfully for treating wastewaters.

Crossref
View Publication
Publication Date
Wed Jun 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
The role of modern manufacturing systems in process Design
...Show More Authors

The aim of the research to measure the correlation relationship between modern manufacturing systems and process design and measure the effect by adopting the regression; the research consists of two main variables, which are modern manufacturing systems and process design; it was applied in the production lines of the General Company for Construction Industries, There is a sample of managers, engineers, technicians, administrators, and some workers were selected to fill the special questionnaire with (70) forms which distributed and (65) were approved suitable for use, For data analysis the correlation coefficient was adopted to measure the relationship and regression analysis to find out the effect, Using (SPSS), So the first h

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
AGENT BASED MONITORING FOR INVESTIGATION PROCESS AND MAINTENANCE IMPROVEMENT
...Show More Authors

Agent technology has a widespread usage in most of computerized systems. In this paper agent technology has been applied to monitor wear test for an aluminium silicon alloy which is used in automotive parts and gears of light loads. In addition to wear test monitoring، porosity effect on
wear resistance has been investigated. To get a controlled amount of porosity, the specimens have
been made by powder metallurgy process with various pressures (100, 200 and 600) MPa. The aim of
this investigation is a proactive step to avoid the failure occurrence by the porosity.
A dry wear tests have been achieved by subjecting three reciprocated loads (1000, 1500 and 2000)g
for three periods (10, 45 and 90)min. The weight difference a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Ni2O3 nanomaterial: Synthesis and characterization by simple chemical process
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Extraction of heavy metals from contaminated soils using EDTA and HCl
...Show More Authors

The present study examines the extraction of lead (Pb), cadmium (Cd) and nickel (Ni) from   a contaminated soil by washing process. Ethylenediaminetetraacetic acid disodium salt (Na2EDTA) and hydrochloric acid (HCl) solution were used as extractants.  Soil washing is one of the most suitable in-situ/ ex-situ remediation method in removing heavy metals. Soil was artificially contaminated with 500 mg/kg (Pb , Cd and Ni ).  A set of batch experiments were carried out at different conditions of  extractant concentration , contact time, pH and agitation speed. The results  showed  that the  maximum removal efficiencies  of (Cd, Pb  and Ni ) were (97, 88 and 24 )&nbs

... Show More
View Publication
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
isolation and identification of cloves oil from eugenia caryophyllaa using Ultrasonic
...Show More Authors

This research has been prepared to isolate and diagnose one of the most important vegetable oils from the plant medical clove is the famous with Alaeugenol oil and used in many pharmaceuticals were the isolation process using a technique ultrasonic extraction and distillation technology simple

View Publication Preview PDF
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Preparation ultra fine particles from Ceramic refractory material using CO2 Laser
...Show More Authors

S a mples of compact magnesia and alumina were evaporated
using CO2-laser .The
Processed powders were characterized by electron microscopy
and both scanning and transmission electron microscope. The results
indicated that the particle size for both powders have reduced largely
to 0.003 nm and 0.07 nm for MgO and Al2O3, with increasing in
shape sphericity.

View Publication Preview PDF
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Aromatic Hydrocarbons from Lube Oil Using Different Co-Solvent
...Show More Authors

An investigation was conducted effect of addition co- solvent on solvent extraction process for two types of a lubricating oil fraction (spindle) and (SAE-30) obtained from vacuum distillation unit of lube oil plant of Daura Refinery. In this study two types of co-solvents ( formamide and N-methyl, 2, pyrrolidone) were blended with furfural to extract aromatic hydrocarbons which are the undesirable materials in raw lubricating oil, in order to improve the viscosity index, viscosity and yield of produced lubricating oil. The studied operating condition are extraction temperature range from 70 to 110 °C for formamide and 80 to 120 °C for N-methyl, 2, pyrrolidone, solvent to oil ratio range from 1:1 to 2:1 (wt./wt.) for furfural with form

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Iron from Al-Hussainyat Iron Ore using Acid Leaching
...Show More Authors

View Publication Preview PDF