Preferred Language
Articles
/
txbcs4cBVTCNdQwC01sp
Assessing the optoelectronic performance of d-orbital doped cubic HfO2: The case of W, Nb, and Mo
...Show More Authors

This contribution provides an atomistic understanding into the impact of W, Nb, and Mo co-substitution at Hf-site of cubic HfO2 lattice to produce Hf1−xTMxO2 system at x = 25%. The calculations have been performed under the framework of density functional theory supported by Habbured parameter (DFT+U). Structural analysis demonstrates that the recorded lattice constants is in good coherence with the previously published results. For the lattice parameters, contraction by 1.33% comparing with the host system has been reported. Furthermore, the doping effect of TM on the band gap leads to its reduction in the resulting Hf0.75TM0.25O2 configurations. The partial density of states (PDOS) indicate that hybridization through localized electronic energy states from TM-5 and 6 d orbitals and O-2 p orbital have participated in narrowing the band gap. Population analysis displays that Hf0.75TM0.25O2 compounds revealed ionic and covalent behavior for Hf-O and TM-O bonds, respectively. The optical investigation portrays that Hf0.75TM0.25O2 systems would absorb a broad range of ultra violet (UV) electromagnetic waves which hence consider them as suitable candidates in optoelectronic memristors industries. Optical analysis also revealed a rise in the optical conductivity and absorption in higher photon energy extent. These compounds are suitable for photovoltaic and other optoelectronic applications. The zero values of the optical conductivity for the simulated systems in a broad range of electromagnetic waves confirm the impossibility of the electronic charge transfer to be occurred through the systems and hence preventing the leakage current which is not preferred in optoelectronic devices such as metal oxide semiconductor field effect transistors (MOSFETs).

Publication Date
Tue Oct 01 2019
Journal Name
Karbala Journal Of Physical Education Sciences
Effect of use a designed device to develop some biochemical variables for rear vault dismount with one-half twist on parallel bars in gymnastics
...Show More Authors

The research included five sections containing the first section on the introduction o research and its importance and was addressed to the importance of the game of gymnastic and skilled parallel bars effectiveness and the importance of biochemical variables, either the research problem that there is a difference in learning this skill and difficulty in learning may be one of the most important reasons are falling and injury Has a negative impact on the performance and lack of sense of movement of is one of the obstacles in the completion of the skill and the goal of research to design a device that helps in the development of biochemical changes to skill of rear vault dismount with one-half twist on parallel bars in gymnastics . And the n

... Show More
Preview PDF
Publication Date
Sun Jan 01 2012
Journal Name
Natural Science
Determination of threshold random gain medium in dye: Polymer films containing TiO<sub>2</sub> nanoparticles
...Show More Authors

View Publication
Crossref
Publication Date
Thu Jun 06 2013
Journal Name
Advances In Physics Theories And Applications
Adsorption study of Symmetrical schiff base ligand 4,4 -[hydrazine -1,2- diylidenebis ( methan-1-yl-1-ylidene) bis ( 2-methoxyphenol)] on Granulated Initiated calcined Iraqi …
...Show More Authors

Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Measuring Lower Uterine Segment Thickness Using Abdominal Ultrasound to Predict Timing of Cesarean Section in Women with Scarred Uterus at Elwiya Maternity Teaching Hospital
...Show More Authors

Background: Ultrasonography has been used to examine the thickness of the lower uterine segment in women with previous cesarean sections in an attempt to predict the risk of scar dehiscence during subsequent pregnancy. The predictive value of such measurement has not been adequately assessed. Objectives: To correlate lower uterine segment thickness measured by trans abdominal ultrasound in pregnant women with previous cesarean section with that measured during cesarean section by caliper and to find out minimum lower uterine segment thickness indicative of integrity of the scar.Methods: A prospective observational study at Elwyia Maternity Teaching Hospital, from January 2011 to January 2012. A total of 143 women were enrolled in the stu

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Thu Oct 03 2013
Journal Name
Heat Transfer-asian Research
CFD Simulation of Heat Transfer Augmentation in a Circular Tube Fitted with Alternative Axis Twisted Tape in Laminar Flow under a Constant Heat Flux
...Show More Authors

View Publication
Scopus (17)
Crossref (15)
Scopus Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Basrah Journal Of Surgery
Can Hyaluronic acid gel enhance wound healing faster than Advanced Platelets Rich Fibrin following surgical removal of impacted mandibular third molars? A Randomized Controlled Trial
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Thu Jan 06 2022
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Instructional Program on Patientsꞌ Knowledge about Home Safety While Receiving Anti -Cancer Medications at Al- Karama Teaching Hospital in Al-Kut City
...Show More Authors

Objectives: To determine the effectiveness of the instructional program on patients’ knowledge about home safety while receiving anti-cancer treatment at  Al- Karama Teaching Hospital in Al-Kut City.

Methodology:   A quasi-experimental design is conducted through the application of a pre-test and post-test approach for the study and control groups from February 5th, 2020 to April 25th, 2020. A non–probability (purposive) sample of (50) patients treated at the Blood Disease and Oncology Center is selected and divided into two groups. Each group contains (25) patients as control and study groups. An instrument is constructed that is comprised of two parts; t

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref