The present study was conducted to investigate the antimicrobial activity of the hot water and the hot ethanolic extracts of Thuja orientalis against some pathogenic microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Eschericha coli, Proteus mirrablis, Salmonilla typhi, Klebsiella pneumoniae, Bacillus cereus, Bacillus subtilus, Acinobacter, Staphylococcus epidermidis and Candida albicans). Results showed that both the water and alcoholic extracts of this plant exert marked inhibitory effect against all the bacterial isolates and yeast and at different ratio, and it was shown that ethanolic extract was more effective in microbial inhibition than the water extract. Maximum inhibition (16 mm) was recorded against Staphylococcus aureus and Candida albicans with the hot water extract, while maximum inhibition was seen against Bacillus cereus by the hot alcoholic extract.
In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m
... Show MoreKA Hadi, AH Asma’a, IJONS, 2018 - Cited by 1
A direct, sensitive and efficient spectrophotometric method for the determination of nitrofurantoin
drug (NIT) in pure as well as in dosage form (capsules) was described. The suggested method was
based on reduction NIT drug using Zn/HCl and then coupling with 3-methyl-2-benzothiazolinone
hydrazone hydrochloride (MBTH) in the presence of ammonium ceric sulfate. Spectrophotometric
measurement was established by recording the absorbance of the green colored product at 610 nm.
Using the optimized reaction conditions, beer’s law was obeyed in the range of 0.5-30 μg/mL, with
good correlation coefficient of 0.9998 and limits of detection and quantitation of 0.163 and 0.544
μg/mL, respectively. The accuracy and
A novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%
... Show MoreEpithelial ovarian cancer is the leading cause of cancer deaths in women. To date, an effective screening tool for ovarian cancer has not been identified Several clinical and biological factors including serum cancer antigen 125 (CA- 125) have been assessed for prognostic and predictive relevance CA-125 is an epithelial marker derived from coelomic epithelium. It is elevated in 90% of advanced ovarian cancers and in 50% of early ovarian cancers while 20% of ovarian cancers have low or no expression of CA- 125 CA-125 concentrations were measured by Mini Vidas test (VIDAS CA125 II / BIOMERIEUX / France). The median CA-125 levels were significantly higher in the sera of ovarian cancer patients than in those with benign tumors an
... Show MoreA simple and novel method was developed by combination of dispersive liquid-liquid microextraction with UV spectrophotometry for the preconcentartion and determination of trace amount of malathion. The presented method is based on using a small volume of ethylenechloride as the extraction solvent was dissolved in ethanol as the dispersive solvent, then the binary solution was rapidly injected by a syringe into the water sample containing malathion. The important parameters, such the type and volume of extraction solvent and disperser solvent, the effect of extraction time and rate, the effect of salt addition and reaction conditions were studied. At the optimum conditions, the calibration graph was linear in the range of 2-100 ng mL-1 of ma
... Show MoreBackground: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou
... Show MoreIn Iraqi patients with acromegaly the present investigation included 40 control group and 70 patients with acromegaly divided 35 patients with Diabetic while another 35 patients without Diabetic, with ages between (29-72) years for the identification of GST activity polymorphisms by present and absent GSTM1, GSTT1, and PCR-RFLP, enzymatic digestions were carried out using BsmAI (Biolabs. England, UK) for GSTP1b and AciI (Biolabs, England, UK) for GSTP1c.the association GSTActivity with GST genotype were investigated in a cohort of Iraq acromegaly patients comparing with the healthy control group. The results show a non-significant change in GSTP1b gene in both groups, while show high significantly in GSTP1c in diabetic and non-diabetic acro
... Show MoreIn this work Different weight of pure Zinc powder suspended particles in 4ml base engine Oil were used.
Intensity of Kα Line was measured for the suspended particles ,also for mixture which consist from Zinc particle blended with Engine base Oil. Calibration Curve was drawn between Ikα line Intensity and Zinc concentration at different operation condition. The Lower Limit detection (LLD) and Sensitivity (m) of Spectrometer were determined for different Zinc Concentration (Wt%). The results of LLD and m for Samples were analyzed at Operation Condition of 30KV,17mA is best from Samples were analyzed at Operation Condition of 25KV,15mA