The Asymmetrical Castellated concavely – curved soffit Steel Beams with RPC and Lacing Reinforcement improves compactness and local buckling (web and flange local buckling), vertical shear strength at gross section (web crippling and web yielding at the fillet), and net section ( net vertical shear strength proportioned between the top and bottom tees relative to their areas (Yielding)), horizontal shear strength in web post (Yielding), web post-buckling strength, overall beam flexure strength, tee Vierendeel bending moment and lateral-torsional buckling, as a result of steel section encasement. This study presents two concentrated loads test results for seven specimens Asymmetrical Castellated concavely – curved soffit Steel Beams section encasement by Reactive powder concrete (RPC) with laced reinforcement. The encasement of the Asymmetrical Castellated concavely – curved soffit Steel Beams consists of, flanges unstiffened element height was filled with RPC for each side, and laced reinforced which are used inclined continuous reinforcement of two layers on each side of the Asymmetrical Castellated concavely – curved soffit Steel Beams web. The inclination angle of lacing reinforcement concerning the longitudinal axis is 45. Seven specimens with seven different configurations will be prepared and tested under two concentrated loads at the mid-third of the beam span. The tested specimen's properties are: unconfined Asymmetrical Castellated Steel Beams (Reference1), second model; Asymmetrical Castellated concavely – curved soffit Steel Beams (web and flange) confined with (RPC) only, third model; Asymmetrical Castellated concavely – curved soffit Steel Beams (web and flange) confined with (RPC) and laced reinforcement, fourth model; is same as the third model but it has one web opening with increase the depth of web post by 10 %, 20%, and 30 % as a gap between top and bottom parts of Asymmetrical Castellated concavely – curved soffit Steel Beams respectively. The results that have been obtained from the experimental part and the numerical analysis results by ABAQUS demonstrated that the increase of the gap leads to an increase in the load against the deflection curve. Sample CB8 with 122 mm gap has gained the highest load against deflection when compared with either reference sample without gap and other samples with 65 mm and 105 mm gap for concavely–curved soffit Steel Beams.
In this study, a three-dimensional finite element analysis using ANSYS 12.1 program had been employed to simulate simply supported reinforced concrete (RC) T-beams with multiple web circular openings subjected to an impact loading. Three design parameters were considered, including size, location and number of the web openings. Twelve models of simply supported RC T-beams were subjected to one point of transient (impact) loading at mid span. Beams were simulated and analysis results were obtained in terms of mid span deflection-time histories and compared with the results of the solid reference one. The maximum mid span deflection is an important index for evaluating damage levels of the RC beams subjected to impact loading. Three experi
... Show MoreThis article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while
... Show MoreThis article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while
... Show MoreIn this paper, a new equivalent lumped parameter model is proposed for describing the vibration of beams under the moving load effect. Also, an analytical formula for calculating such vibration for low-speed loads is presented. Furthermore, a MATLAB/Simulink model is introduced to give a simple and accurate solution that can be used to design beams subjected to any moving loads, i.e., loads of any magnitude and speed. In general, the proposed Simulink model can be used much easier than the alternative FEM software, which is usually used in designing such beams. The obtained results from the analytical formula and the proposed Simulink model were compared with those obtained from Ansys R19.0, and very good agreement has been shown. I
... Show MoreIn the present work the Buildup factor for gamma rays were studied in shields from epoxy reinforced by lead powder and by aluminum powder, for NaI(Tl) scintillation detector size ( ×? ), using two radioactive sources (Co-60 and Cs-137). The shields which are used (epoxy reinforced by lead powder with concentration (10-60)% and epoxy reinforced by aluminum powder with concentration (10-50)% by thick (6mm) and epoxy reinforced by lead powder with concentration (50%) with thick (2,4,6,8,10)mm. The experimental results show that: The linear absorption factor and Buildup factor increase with increase the concentration for the powders which used in reinforcement and high for aluminum powder than the lead powder and decrease with inc
... Show MoreThis study examines the position of comparative legislation (French legislation, English legislation, and Egyptian legislation) in addressing the regulation of personal civil liability (based on fault) for the government. About the damages caused by demonstrations in terms of their legal nature, their legal basis, and the pillars and conditions of that responsibility. Then, we explain the position of the Iraqi legislator and compare it with what is the case in the legislation mentioned above
Porous Silicon (PSi) has been produced in this work by using Photochemical (PC) etching process by using a hydrofluoric acid (HF) solution. The irradiation has been achieved using quartz- tungsten halogen lamp. The influence of various irradiation times on the properties of PSi اmaterial such as layer thickness, etching rate and porosity was investigated in this work too.
The XRD has been studied to determine the crystal structure and the crystalline size of PSi material