Christianity rejected abortion, since its inception, it took a luck against abortion, although there is no mention of it in the Bible, as there is no explicit text for abortion in the Old or New Testament and that the early Christians considered abortion a sin in all stages, and beliefs included abortion as an act of murder. What is forbidden in the Ten Commandments is “Thou shalt not kill”, and it is understood that killing here is either plundering one’s personal life (suicide) or stealing another person’s life (killing), or stealing the life of a person who has not yet been born (aborting fetuses). Based on the above, it was necessary for individuals to search for (Abortion in the Christian Religion / Descriptive Study) The research was divided into an introduction and two topics, the introduction describes the meaning of abortion in language and convention, while the first topic was devoted to studying abortion from the perspective of the Christian religion and the position of the church fathers, and the second study was devoted to studying the legitimacy of the rule of abortion in our besieged world And the opinion of its supporters and the response to them, preceded by an introduction and followed by a conclusion, and a list of sources and references.
Abstract:
Objective: To self-evaluate the effect of SBAR (Situation, Background, Assessment, and Recommendation) educational program on nurse and midwives practices in maternal health report documentation accuracy.
Methods: A quasi- experimental design was carried with the application of pre- post test for nurses and midwives’ knowledge and practices regarding SBAR communication tool. The study was held in Al-Elwia maternity teaching hospital, Al –Karckh maternity hospital and Al-Yarmouk teaching Hospital. purposive sample as it was convenient with inclusion criteria consisted of (84) nurse and midwives. The questionnaire comprised of demographic data, nurses- midwives practices of SBAR using (5) level Likert scale for assessme
In this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init
... Show MoreThree mesoporous silica with different functional group were prepared by one-step synthesis based on the simultaneous hydrolysis and condensation of sodium silicate with organo - silane in the presence of template surfactant polydimethylsiloxane - polyethyleneoxide (PDMS - PEO). The prepared materials were characterized by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), atomic force microscopy (AFM) and nitrogen adsorption/desorption experiments. The results indicate that the preparation of methyl and phenyl functionalized silica were successful and the mass of methyl and phenyl groups bonded to the silica structure are 15, 38 mmol per gram silica. The average diameter of the silica particles are 103.51,
... Show MoreIn this research, the kinetic studies of four isoenzymes of Asprtate aminotransferase, which partially purified from the urine of chronic renal failure patients were carried out .The four isoenzymes were obeyed Michaelis-Menton's equation and the optimum concentration of their substrate (Aspartic acid) was (166.5x10-3) mole/liter,and their Km values were determined. Four isoenzymesI,II,III,IV have shown an optimum pH at 7.4.The four isoenzymes obeyed Arrhenius equation up to 37º C and their Ea and Q10 constants were determined .
Bipedal robotic mechanisms are unstable due to the unilateral contact passive joint between the sole and the ground. Hierarchical control layers are crucial for creating walking patterns, stabilizing locomotion, and ensuring correct angular trajectories for bipedal joints due to the system’s various degrees of freedom. This work provides a hierarchical control scheme for a bipedal robot that focuses on balance (stabilization) and low-level tracking control while considering flexible joints. The stabilization control method uses the Newton–Euler formulation to establish a mathematical relationship between the zero-moment point (ZMP) and the center of mass (COM), resulting in highly nonlinear and coupled dynamic equations. Adaptiv
... Show More