Preferred Language
Articles
/
tReXdpIBVTCNdQwCSrDL
Asymptotic Stability of 3D Stochastic Positive Linear Systems with Delays
...Show More Authors

The article emphasizes that 3D stochastic positive linear system with delays is asymptotically stable and depends on the sum of the system matrices and at the same time independent on the values and numbers of the delays. Moreover, the asymptotic stability test of this system with delays can be abridged to the check of its corresponding 2D stochastic positive linear systems without delays. Many theorems were applied to prove that asymptotic stability for 3D stochastic positive linear systems with delays are equivalent to 2D stochastic positive linear systems without delays. The efficiency of the given methods is illustrated on some numerical examples. HIGHLIGHTS Various theorems were applied to prove the asymptotic stability of 3D stochastic positive linear system with delays. Moreover, this system can be reduced to 2D stochastic positive linear system without delays Asymptotic stability of 3D stochastic positive linear systems with delays depends on the summation of system matrices and independent on numbers and values of delays for that system The principal minors and the coefficients for characteristic polynomials of 3D stochastic linear systems were applied to demonstrate the asymptotic stability when they are all positive

Scopus Crossref
View Publication
Publication Date
Tue Sep 03 2019
Journal Name
Rawal Medical Journal
Evaluation of Radial Nerve Injury Associated with Closed Humeral Shaft Fracture by Early Pre-operative Ultrasonic Evaluation and Correlation with Surgical Exploration
...Show More Authors

Traumatic radial nerve injury in humeral shaft fracture is the most common traumatic nerve injury in long-bone fracture, with overall prevalence 2-18%, ranging from traction to complete transection. Spontaneous recovery may reach 88%. The aim of the study is to assess the sensitivity & specificity of the ultrasound to detect the radial nerve injury and to see if this can be used as a diagnostic test. This is a prospective study on 17 adult patients with a closed fracture of the humeral shaft, dividing into two groups, the first group of 7 patients had signs and symptoms of radial nerve palsy at presentation and the second group of 10 patients had intact radial nerve function was considered as a control group. All these patients had at leas

... Show More
View Publication Preview PDF
Scopus
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Fracture Resistance of Endodontically Treated Premolar Teeth with Extensive MOD Cavities Restored with Different Bulk Fill Composite Restorations (An In vitro Study)
...Show More Authors

Background: The present in-vitro study was undertaken to evaluate and compare fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different bulk fill composite restorations (EverX posterior, Alert, Tetric EvoCeram Bulk Fill, and SDR). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Forty-eight human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into six groups of eight teeth each (n=8): (Group 1) intact control group, (Group 2) unrestored teeth with

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Oct 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Beta angle in a sample of Iraqi adults with Class I skeletal and dental relations and its correlation with other craniofacial measurements
...Show More Authors

Background: This study aimed to determine the value of Beta angle for a sample of Iraqi adults with class I skeletal and dental relations and to verify the existence of sexual dimorphism and to find out the relation between this angle and other craniofacial measurements. Materials and Methods: Sixty dental students (23 males and 37 females) with an age ranged between 20-31 years old and having class I skeletal and dental relations were chosen for this study. Each student was subjected to clinical examination and digital true lateral cephalometric radiograph. The radiographs were analyzed using AutoCAD 2007 computer program to measure the angular and linear variables. Descriptive statistics were obtained for the measurements for both genders

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Catalytic Reduction of NOx using Locally Prepared Catalysts with Ammonia
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Aeroelastic Flutter of Subsonic Aircraft Wing Section with Control Surface
...Show More Authors

Aeroelastic flutter in aircraft mechanisms is unavoidable, essentially in the wing and control surface. In this work a three degree-of-freedom aeroelastic wing section with trailing edge flap is modeled numerically and theoretically. FLUENT code based on the steady finite volume is used for the prediction of the steady aerodynamic characteristics (lift, drag, pitching moment, velocity, and pressure distribution) as well as the Duhamel formulation is used to model the aerodynamic loads theoretically. The system response (pitch, flap pitch and plunge) was determined by integration the governing equations using MATLAB with a standard Runge–Kutta algorithm in conjunction with Henon’s method. The results are compared with

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 15 2023
Journal Name
International Journal Of Biomaterials
A Novel Coating of Orthodontic Archwires with Chlorhexidine Hexametaphosphate Nanoparticles
...Show More Authors

Statement of the Problem. The use of orthodontic fixed appliances may adversely affect oral health leading to demineralizing lesions and the development of gingival problems. Aims of the Study. The study aimed to coat orthodontic archwires with chlorhexidine hexametaphosphate nanoparticles (CHX-HMP NPs) and to evaluate the elusion of CHX from CHX-HMP NPs. Materials and Methods. A solution of CHX-HMP nanoparticles with an overall concentration of 5 mM for both CHX and HMP was prepared, characterized (using atomic force microscope and Fourier transformation infrared spectroscopy), and used to coat orthodontic stainless steel (SSW) and NiTi archwires (NiTiW). The coated segments were characterized (using scanning electron microscopy

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Numerical Simulation of flow in pipe with cross jet effects
...Show More Authors

A numerical method is developed to obtain two-dimensional velocity and pressure distribution through a cylindrical pipe with cross jet flows. The method is based on solving partial differential equations for the conservation of mass and momentum by finite difference method to convert them into algebraic equations. This well-known problem is used to introduce the basic concepts of CFD including: the finite- difference mesh, the discrete nature of the numerical solution, and the dependence of the result on the mesh refinement. Staggered grid implementation of the numerical model is used. The set of algebraic equations is solved simultaneously by “SIMPLE” algorithm to obtain velocity and pressure distribution within a pipe. In order to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Behavior of Strengthened RC Columns with CFRP under Biaxial Bending
...Show More Authors

In this work, the behavior of reinforced concrete columns under biaxial bending is studied. This work aims at studying the strengthening of columns by using carbon fiber reinforced polymer (CFRP). The experimental work includes investigation of eight reinforced concrete columns (150*150*500mm) tested under several load conditions. Variables considered in the test program include; effect of eccentricity and effect of longitudinal reinforcement (Ø12mm or Ø6mm). Test results are discussed based on load – lateral deflection behavior, load –longitudinal deflection behavior, ultimate load and failure modes. The CFRP reinforcement permits
a complete change in the failure mode of the columns .The effect of longitudinal reinforcement in

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Impact of functional disability on lifestyle for patients with arthritis
...Show More Authors


A descriptive study, which was using an assessment approach, was conducted for the
determination of the impact of rheumatoid arthritis and osteoarthritis patient’s functional disability
upon their life style. The study was carried out at the Rheumatology and outpatients clinics of ALKarama
Teaching Hospital, Baghdad Teaching Hospital AL-Kindey Teaching Hospital and Specialized
surgeries Teaching Hospital for the period of October 15th 2003 through May 13th 2004 in Baghdad
City. A purposive (non-probability) sample of (245) arthritis patients which was comprised (111)
rheumatoid arthritis patients and (134) osteoarthritis patients, was selected out of the early stated
settings. The questionnaire was comprised of

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Computational And Theoretical Nanoscience
Controlling of Robot Hand by Using Microcontroller with Visual Basic
...Show More Authors

The robot arm is the most popular robotic form used in industry. Thus, it is crucial to make a system programming which could controlled the movement of each part in the industrial robot to make it works properly. One of the simplest models of the robot arm is EDARM ED-7100 which has a controller to control the movement of the robot arm manually. In this study, the robot controller has been redesigned in order to improve this robot's function. The new controller system used AT89S52 microcontroller which has wire connected to the robot hand. A function has been added with this controller to improve the system of controlling and becomes better than the previous system (only manually). The functions of the new system include three mo

... Show More
View Publication
Scopus Crossref