Static and dynamic circumstances confirm that seepage is water movement through the earth dam’s embankment’s voids from upstream to downstream. Seepage is a quantity of fluid that has seeped through the permeable material or as the infiltration downward and lateral movement of water into soil or substrata from a source of supply such as a reservoir of a dam. In case of an earthquake strikes saturated soils, the water-filled pore spaces collapse, reducing the soil’s overall volume. The water pressure between individual soil grains is increased as a result of this action, and the grains can then move freely in the watery matrix. This reduces the soil’s resistance to shear stress and causes the mass of soil to take on liquid-like qualities. Soil deforms quickly in its liquefied state, and massive items such as structures can be destroyed by the rapid loss of support from below. This study employs finite element method (FEM) analysis to examine the seepage under static and dynamic condition and effect of earthquake on the Darbandikhan earth dam seepage. The study adopted the maximum head of water equal to 486 m.a.s.l. meter above sea level, the peak acceleration of earthquake was 0.15, 0.3 and 0.5 m2/s, time = 25s, and five history points in upstream and downstream were assessed. Geo-studio software represented by the programs like SEEP/W and quake/w that support the numerical analysis system under seismic influence were used. The results showed that the amount of seepage under seismic action was significantly influenced and increased as the peak acceleration of the earthquake increased. Therefore, the significance of the findings in terms of practical application for engineers and decision-makers involved in dam safety measures.
The vortex rate sensor is a fluidic gyroscope with no moving parts and can be used in very difficult
conditions like radiation, high temperature and noise with minimum cost of manufacturing and
maintenance. A vortex rate sensor made of wood has been designed and manufactured to study
theoretically and experimentally its static performance .A rig has been built to carry out the study,
the test carried out with three different air flow rates (100, 150, and 200 l/min).The results show that
the relation between the differential pressure taken from the sensor pickoff points and the angular
velocity of the sensor was linear.The present work involved theoretical and experimental study of
vortex rate sensor static characteri
In Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c
... Show MoreDiyala Governorate was exposed recently to high flood waves discharged from Hemrin Dam to Diyala River when the dam reached its full capacity. The recently recorded discharge capacity of Diyala River was reduced to just 750m3/s. This exposes cities and villages along the Diyala River to flood risk when discharging the flood waves, which may reach 3000 m3/s. It is important to manage, suggest, and design flood escapes to discharge the flood waves from Hemrin Dam away from Diyala River. This escape branches from Hemrin Lake towards Ashweicha Marsh. One dimensional hydraulic model was developed to simulate the flow within the escape by using HEC-RAS software. Eighty-two cross-sections were ext
... Show MoreAn experimental study was performed to estimate the forced convection heat transfer performance and the pressure drop of a single layer graphene (GNPs) based DI-water nanofluid in a circular tube under a laminar flow and a uniform heat flux boundary conditions. The viscosity and thermal conductivity of nanofluid at weight concentrations of (0.1 to 1 wt%) were measured. The effects of the velocity of flow, heat flux and nanoparticle weight concentrations on the enhancement of the heat transfer are examined. The Nusselt number of the GNPs nanofluid was enhanced as the heat flux and the velocity of flow rate increased, and the maximum Nusselt number ratio (Nu nanofluid/ Nu base fluid) and thermal performance factor
... Show MoreReceipt date:9/1/2020 accepted date:11/24/2020 Publication date:12/31/2021
This work is licensed under a Creative Commons Attribution 4.0 International License.
the Nile River and the Renaissance Dam is one of the most prominent factors that had an important role in the nature of relations between Egypt - Ethiopia, as they contributed to building a relationship that has common characteristics through the nature of the i
... Show MoreThe seismic can be threatened the stability of the flexible body of the earth dam and can cause completely damaged or deformation on their embankment. Therefore, a geotechnical engineer needs to know the effect of earthquakes on earth structures. The change in the seismic zone that recently Iraq affected is the reason for this research, in general, in 2017, the whole of Iraq, and in particular the region, where the Al-Wand earth dam (the subject of the study) is located, was exposed to several earthquakes. This research project mainly aims to study the behavior of Al-Wand earth dam under seismic load in different conditions by simulating Al-Wand earth dam through numerical modeling an
This research examines the relationship between dinar deposits and U.S. dollar payments at the Central Bank of Iraq using monthly data for the period 2016–2025. The ARDL model, the GRU neural network, and a hybrid ARDL–GRU model are applied. The results show that dollar payments are stationary at level, while dinar deposits become stationary after first differencing, with a significant positive long-run cointegrating relationship. The linear ARDL model has limited ability to capture sudden shocks, whereas the hybrid ARDL–GRU model achieves superior forecasting performance both in-sample and out-of-sample. The findings confirm the Central Bank of Iraq’s efficiency in managing domestic and foreign liquidity and maintaining market stab
... Show MoreIn this paper, the static analysis for finding the best location of boxes inside the composite wing-box structure has been performed. A software ANSYS (ver.11) was used to analyses the Aluminum wing to find the maximum stresses reached in. These results are used as a base for the composite wingbox to find the numbers of layers and location of the box beam and its dimensions so that the composite wingbox may carry the same loading conditions in the Aluminum wing. Analysis showed that a composite wingbox having two boxes is better than the single or triple boxes wing based on stress to weight ratio. Mass saving of (40%) had been achieved when composite wing-box is used instead of Aluminum wing.
The Jeribe Formation, the Jambour oil field, is the major carbonate reservoir from the tertiary reservoirs of the Jambour field in northern Iraq, including faults. Engineers have difficulty organizing carbonate reserves since they are commonly tight and heterogeneous. This research presents a geological model of the Jeribe reservoir based on its facies and reservoir characterization data (Permeability, Porosity, Water Saturation, and Net to Gross). This research studied four wells. The geological model was constructed with the Petrel 2020.3 software. The structural maps were developed using a structural contour map of the top of the Jeribe Formation. A pillar grid model with horizons and layering was designed for each zone. Followin
... Show MoreThis paper shows the characteristics of temperature and adsorbed (water vapor) mass rate distribution in the adsorber unit which is the key part to any adsorption refrigeration system. The temperature profiles of adsorption/desorption phases (Dynamic Sorption) are measured experimentally under the operating conditions of 90oC hot water temperature, 30oC cooling water temperature, 35oC adsorption temperature and cycle time of 40 min. Based on the temperature profiles, The mass transfer equations for the annulus adsorbent bed are solved to obtain the distribution of adsorption velocity and adsorbate concentration using non-equilibrium
model. The relation between the adsorption velocity with time is investigated during the process of ads