The novel Vierordt’s approach, or simultaneous equation method, was created and validated for the concurrent determination of vincristine sulfate (VCS) and bovine serum albumin (BSA) in pure solutions utilizing UV spectrophotometry. It is simple, precise, economical, rapid, reliable, and accurate. This method depends on measuring absorbance at two wavelengths, 296 nm and 278 nm, which correspond to the λmax of VCS and BSA in deionized water, respectively. The calibration curves of VCS and BSA are linear at concentration ranges of 10–60 μg/mL and 200–1600 μg/mL, with correlation coefficient values (R2) of 1 and 0.999, respectively. The limits of detection (LOD) and quantification (LOQ) were 0.465 μg/mL and 1.410 μg/mL for VCS and 41.096 μg/mL and 124.533 μg/mL for BSA. The precision investigation indicated that the relative standard deviation (RSD) value was within limitations (RSD < 2%). The percentage recovery varied between 99.40 and 103.20% for VCS and 97.90 and 102.54% for BSA at various concentration levels, demonstrating that the simultaneous equation technique is accurate. The suggested approach can be successfully applied to estimate VCS and BSA simultaneously in pure and pharmaceutical-marketed products comprising these two components.
Background: Gingival crevice fluid (GCF) is a mixture of substances derived from serum, leukocytes, and structural cells of periodontium and oral bacteria. These substances possess a great potential for serving as indicators of periodontal disease and healing after therapy the main purpose of this study was to find if there is a difference in albumin concentration between healthy and diseased periodontal tissues and to compare between diseased group according to pocket depth Materials and methods: total sample composed of 60 pockets found in 35 patients all of them had no history of any systemic disease, The samples were divided in to three main group that include two diseased groups divided according to the depth of the periodontal pocket
... Show MoreThe research presents the reliability. It is defined as the probability of accomplishing any part of the system within a specified time and under the same circumstances. On the theoretical side, the reliability, the reliability function, and the cumulative function of failure are studied within the one-parameter Raleigh distribution. This research aims to discover many factors that are missed the reliability evaluation which causes constant interruptions of the machines in addition to the problems of data. The problem of the research is that there are many methods for estimating the reliability function but no one has suitable qualifications for most of these methods in the data such
This work discusses the beginning of fractional calculus and how the Sumudu and Elzaki transforms are applied to fractional derivatives. This approach combines a double Sumudu-Elzaki transform strategy to discover analytic solutions to space-time fractional partial differential equations in Mittag-Leffler functions subject to initial and boundary conditions. Where this method gets closer and closer to the correct answer, and the technique's efficacy is demonstrated using numerical examples performed with Matlab R2015a.
In this paper, a subspace identification method for bilinear systems is used . Wherein a " three-block " and " four-block " subspace algorithms are used. In this algorithms the input signal to the system does not have to be white . Simulation of these algorithms shows that the " four-block " gives fast convergence and the dimensions of the matrices involved are significantly smaller so that the computational complexity is lower as a comparison with " three-block " algorithm .
To detect the amount of rifampicin in bulk and medicinal dosage formulations, an accurate and costeffective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of rifampicin. This range of wavelengths (300–356 nm) was chosen. The method showed linearity in the 2–22 μg/mL range, with R2 being2 0.9996. The developed method’s linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the str
... Show MoreTo detect the amount of Rifampicin in bulk and medicinal dosage formulations, an accurate, and cost-effective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of Rifampicin. This range of wavelengths (300–356) nm was chosen. The method showed linearity in the 2-22 μg/mL range, with R2 being 0.9996. The developed method' linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of Rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the struct
... Show MoreThis research includes the study of dual data models with mixed random parameters, which contain two types of parameters, the first is random and the other is fixed. For the random parameter, it is obtained as a result of differences in the marginal tendencies of the cross sections, and for the fixed parameter, it is obtained as a result of differences in fixed limits, and random errors for each section. Accidental bearing the characteristic of heterogeneity of variance in addition to the presence of serial correlation of the first degree, and the main objective in this research is the use of efficient methods commensurate with the paired data in the case of small samples, and to achieve this goal, the feasible general least squa
... Show MoreKE Sharquie, WS Al-Dori, IK Sharquie, AA Al–Nuaimy, Hospital, 2004 - Cited by 20
S Khalifa E, N Adil A, K Nabeel O…, 2008