Four different spectrophotometric methods are used in this study for the determination of Sulfamethoxazole and sulfanilamide drugs in pharmaceutical compounds, synthetic samples, and in their pure forms. The work comprises four chapters which are shown in the following: Chapter One: Includes a brief for Ultraviolet-Visible (UV-VIS) Absorption spectroscopy, antibacterial drugs and sulfonamides with some methods for their determination. The chapter lists two methods for optimization; univariate method and multivariate method. The later includes different types, two of these were mentioned; simplex method and design of experiment method. Chapter Two: Includes reaction of the two studied drugs with sodium nitrite and hydrochloric acid for diazotization reaction followed by coupling with diphenylamine in acidic medium to form, a blue colored azo dye compound which exhibits maximum absorption (λmax) at 530 nm for sulfamethoxazole complex and 531 nm for sulfanilamide complex against the reagent blank and the concentration of these drugs were determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. In addition to classical univariate optimization, modified simplex method has been applied in optimization of the variables affecting the color producing reaction. The results show better optical characteristics for calibration curves and statistical data were obtained under optimum conditions obtained by multi simplex optimization, in comparison with those obtained via univariate method for two studied drugs. Beer’s law obeyed in the concentration range of 0.5-12.0 μg.mL-1, 0.5-7.0 μg.mL-1 for sulfamethoxazole and sulfanilamide respectively with molar absorptivity of 4.9617×104 L.mol-1.cm-1 for sulfamethoxazole and 5.9185×104 L.mol-1.cm-1 for sulfanilamide. The detection limits were 0.036 μg.mL-1 and 0.016 µg.mL-1 for the two complexes respectively by simplex method. No interferences from the studied excipients on the determination of these drugs were found therefore, the proposed methods were applied successfully II for the determination of the sulfamethoxazole and sulfanilamide in pharmaceutical compound and in synthetic samples. Chapter Three: Is based on the formation of condensation complexes of each drug with sodium 1,2-naphthoquinon-4-sulfonate as a chromogenic reagent. The absorbance values, for the formed complexes were measured at 460 nm for sulfamethoxazole and 455 nm for sulfanilamide; against reagent blank. Different variables affecting the completion of reaction have been carefully optimized following the classical univariate sequence and design of experiment (DOE) method and the results were obtained under optimum conditions by (DOE) optimization which shows better optical characteristics for calibration curves and statistical data in comparison with those obtained via univariate method for two studied drugs. The calibration graphs are linear in the ranges of (5.0-50.0) µg.mL-1 for sulfamethoxazole and (5.0-30.0) µg.mL-1 for sulfanilamide with detection limit 0.359 µg.mL-1for sulfamethoxazole complex and 0.536 µg.mL-1 for sulfanilamide complex. The molar absorptivity was found to be (7.0918×104 L.mol-1.cm-1) for sulfamethoxazole and (7.0774×104 L.mol-1.cm-1) for sulfanilamide by the design of experiment (DOE) method. Finally no interferences from the studied excipients on the determination of these drugs were found. The proposed methods have been successfully applied for the determination of sulfamethoxazole and sulfanilamide in their pharmaceutical preparation and synthetic samples. Chapter Four: Includes two parts; Derivative spectrophotometry and partial least-squares (PLS). Derivative spectrophotometry is based on the first and second derivative spectra of absorption which has been applied for simultaneous spectrophotometric determination of sulfamethoxazole and sulfanilamide in their mixture in the ultraviolet region. The method offers an advantage of getting rid of the resulting error in the values of absorption because of the presence of each drug with the presence of interferences from the excipients. It was found that the method is able to accurately estimate sulfamethoxazole in the range of (2.0-50.0) μg.mL-1; in mixtures containing III (2.0-30.0) μg.mL-1 of sulfanilamide, as (interferent). The results obtained, with the first derivative measurements, indicate that when the concentration of sulfanilamide is kept constant and the concentration of sulfamethoxazole varied, the peak amplitudes are measured at peak-to-baseline (223, 254,287 nm), peak to peak height between (223- 254 nm), (254-287nm). Moreover, the height at the zero cross of sulfanilamide at (235.62, 258.72 nm), heightto-height of the two zero crosses between (235.62-258.72 nm) and area under peak between (241.95-267.04 nm), (267.04-330 nm) were found to be in proportion to the sulfamethoxazole concentration therefore they are used for the determination of it. The careful inspection of the second derivative spectra obtained for the mentioned mixtures of sulfamethoxazole and sulfanilamide shows that peak to basline is at (239.5, 263.5, 267.75, 301, 215 nm) , height to basline is at zero cross is at (245.86, 271.28 nm) , peak to peak is between (239.5-264.25 nm), (239.5-267.75 nm), (271.28-301 nm), (215-239.5 nm), height to height is at two zero cross (245.86-271.28 nm) in addition to peak area at the interval between (254.12-281 nm), (286.95- 329.5 nm), (221.75-254.12 nm) measurements at specified wavelength could be used to quantify the exact concentration of sulfamethoxazole in presence of sulfanilamide. Sulfanilamide was determined for the range of (2.0-50.0) μg.mL-1; in a mixture containing (2.0-50.0) μg.mL-1 of sulfamethoxazole as (interferent). The procedure gave good results over the studied range of concentration depending on peak-to-baseline at (224, 246, 271 nm), height at zero cross at (241.95, 267.04 nm), peak to peak between (224-246 nm), (246-271 nm), height to height at two zero cross (241.95-271 nm) and area under the peak at (235.62-258.72 nm) measurements were found to be used for the determination of sulfanilamide in the first derivative technique. On other situation, the wavelengths are at 218 nm, 231 nm, 260 nm and 278 nm (peak to base line measurements), and height at two zero cross at 254 nm and 281 nm, and peak to peak measurements between (218-231 nm), (231-260 nm) and (260-278 nm), and height at zero cross at (254, 281 nm), wavelengths at (210-224 nm) , (224-245.84 nm) and (271.28-330 nm) peak area at the interval measurements were used for the estimation of sulfanilamide on second derivative.
This study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were th
... Show MoreHands have consistently been an important vehicle in the transmission of disease (1). Thus, thorough hand-washing remains the single most important factor in preventing infection specially in hospitals and labs.Twenty-nine non-clinical volunteers (do not work or come in contact with a clinical or hospital setting) that lacked visible skin injuries, eczema or apparent skin disease were used, those subjects were all tested by a material of each of the three used in the study weekly and laboratory tests were done pre- and post washing.All three material were effective , Eugenol extract as effective as the bar and lotion soap. And this was confirmed statistically.Eugenol has a great antibacterial action even in small concentration and t
... Show MoreBackground: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation. Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation. Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pain, or low back and sciatica pain for last 12 weeks, while patients
... Show MoreThe main objective of this study is to experimentally investigate the effect of the CMC polymeric drag reducer on the pressure drop occurred along the annulus of the wellbore in drilling operation and investigate the optimum polymer concentration that give the minimum pressure drop. A flow loop was designed for this purpose consist from 14 m long with transparent test section and differential pressure transmitter that allows to sense and measure the pressure losses along the test section. The results from the experimental work show that increasing in polymer concentration help to reduce the pressure drop in annulus and the optimum polymer concentration with the maximum drag reducing is 0.8 kg/m3. Also increasing in flow rate a
... Show MoreObesity is disorder in a foremost nutritional health it’s developed with countries developing. Also is known as increasingin fat accumulation that lead toproblem in health, besidesmay coin one of the reasons lead toloss of life,the obesity not effect on adults just but effect onoffspringand juveniles. In some ofinhabitants the incidence of obesity is superior in female than in male; on the other hand, the variation degree of the between the genderdifferby country.Obesity is generally measured by body mass index and waist circumference, Obesity are classified according to body mass index into:Pre obesity sort 1 : (25 - 29.9) kg/m2, Obesity sort 2 : (30 - 34.9 kg/m2) and extreme obesity sort 3: (40 kg/m2) or greater. Obesity is described by
... Show MoreThe vacancy of natural resources is undoubtedly limited by time. The sustainable development principle recommends modern technology for its protection and renewal. This project conducted analyses on two underground water sources in the north of Algeria (Mechroha Province). Besides, the use of the hardness factor and the adoption of the titration method, which is the determining the concentration of an unknown solution using a known solution concentration, have permitted the characterization of the examples taken and to verify their conformity to the standard required, the results found showed HT=6.66 French degrees (oF) ) for Ain Guilloume water spring in comparison to Ain Messai water spring H
Both of the species Typha domengensis and Phragmites communis among the most important plant endemic in flora of Iraq from monocotyledon. Due to the similarity of the two species with each other in many morphological characteristics such as the environment where they live and the form of leaves and type of leaf venation and type of stomata….ets, also both of species belong to monocots plant therefore this research work was conducted find anatomical differences that have the same as taxonomic value to help distinguishing between both species under study. Through this research, we found great importance to the anatomical characteristics which we reached by studying th
... Show MoreA new class of higher derivatives for harmonic univalent functions defined by a generalized fractional integral operator inside an open unit disk E is the aim of this paper.
A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .