Preferred Language
Articles
/
rxbAzIsBVTCNdQwCPd8a
Evaluation of Different Internal Designs of Hydraulic Nozzles under an Accelerated Wear Test
...Show More Authors

The use of worn-out agricultural nozzles in pesticide application has a negative effect on the efficiency and cost of the application process. It also has an effect on environmental pollution due to an excessive amount of pesticide being applied when spraying with worn-out nozzles. In this paper, the resistance to wear of three different internal design hydraulic nozzles was ascertained. Changes in the flow rate and spray distribution as a result of this wear were also investigated. The wear test was done inside a closed system, and it was accelerated using an abrasive material to generate 100 h of wear. The tested nozzles were the Turbo TeeJet (TT)-twin chambered, Turbo Twinjet (TTj60)-dual outlet, and Drift Guard (DG)-pre-orifice. Wear rate, flow rate, and the virtual coefficient of variation (CVv) were measured at different wear intervals. The results showed that the TTj60 type was the most resistant to wear, followed by the TT type and DG. The latter two types showed an increase in the flow rate only in the first 45 h of wear. Virtual coefficient of variation (CVv) values were less than 10% after finishing the test (after 100 h of wear) for the three types of nozzles, which are acceptable values according to International Organization for Standardization (ISO) 16122-2, 2015.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental Simulation of Natural Heat Convection from Finned Vertical Plate with Different Inclinations
...Show More Authors

In this work an experimental simulation is made to predict the performance of steady-state natural heat convection along heated finned vertical base plate to ambient air with different inclination angles and configurations of fin array. Two types of fin arrays namely vertical fins array and V-fins array on heated vertical base plate are used with different heights and spaces. The influence of inclination angle of the plate , configuration of fins array and fin geometrical parameters such as fin height and fin spacing on the temperature distribution, base convection heat transfer coefficient and average Nusselt number have been plotted and discussed. The experimental data are correlated to a formula between average Nusselt number versus R

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 10 2007
Journal Name
Iraqi Journal Of Laser
Combination Effect of Laser, Antibiotics and Different Temperature on Locally Isolated Pseudomonas aeruginosa
...Show More Authors

In humans, Pseudomonas aeruginosa is the second most frequent gram negative nosocomial pathogen in hospitals and has the highest case-fatality rate of all hospital-acquired bacteremia because of the hardy resistance of these bacteria to mechanical cleansing as well as to disinfectant, and many antibiotics. The susceptibility of bacteria against the antibiotics is modulated by several local factors such as temperature which modified drug efficacy, so this study was carried out to evaluate the effect of different temperature (20,42,45)Ċon the susceptibility of Pseudomonas aeruginosa to the minimum inhibitory concentrations (MIC) of the antimicrobial agents before and after irradiation. The samples collected from 150 persons suffering from

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 15 2013
Journal Name
Eng. & Tech. Journal,
Assessment the Impact of Different Hydrated Lime Addition Methods on Fatigue Life Characteristic
...Show More Authors

The purpose of this study is to evaluate the effect of hydrated lime addition methods as filler replacement on fatigue performance of Hot Mix Asphalt (HMA). Three types of addition methods of hydrated lime were introduced namely dry HL on dry aggregate and saturated surface aggregate above 3% and slurry HL on dry aggregate, ordinary Lime stone powder was reduced by three HL percentage (1.0, 2.0 and 3.0 %). The effect of different methods were investigated on the fatigue properties of HMA using, third-point flexural fatigue bending Test. Pneumatic Repeated Load System (PRLS) was carried out to establish the effect of hydrated lime on the fatigue failure criteria and to select the proper hydrated lime application methods on fatigue behavior o

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jan 30 2018
Journal Name
Iraqi Journal Of Science
Improve the Spatial Resolution of Multispectral satellite Image using Different Image Sharpening Techniques
...Show More Authors

The process of combining the significant information from a series of images into a single image called image sharpening or image fusing, where the resultant fused image will be having more spatial and spectral information than any of the input images. in this research two images of the same place in different spatial resolution have been used the first one was panchromatic and the second image was multispectral with spatial resolution 0.5m and 2 m respectively. These images were captured by world view-2 sensor. This research resent four pan sharpening methods like (HSV, Brovey (color normalizes) , Gram shmidt and PCA)these methods were used to combine the adopted images to get multispectral image

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Study of Molecular Interaction for Antibiotic Drug with Sugar Solutions at Different Temperature
...Show More Authors

The interactions of drug amoxicillin with maltose or galactose solutions with a variation of temperature have been discussed by taking in the volumetric and viscometric procedures. Physical properties [densities (ρ) and viscosities (η)] of amoxicillin (AMOX) aqueous solutions and aqueous solutions of two type saccharides (maltose and galactose 0.05m) have been measured at T = (298.15, 303.15 and 308.15) K under atmospheric pressure. The apparent molar volume (ϕv cm3mole-1) has been evaluated from density data and fitted to a Redlich-Mayer equation. The empirical parameters of the Mayer-Redlich equation and apparent molar volume at infinite dilution Ø°v were explicated in terms of interactions from type solute-solvent and solute

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Feb 27 2011
Journal Name
University Of Baghdad
Determination of Cimetidine and Erythromycin ethylsuccinate Drugs Using Different Spectrophotometric Methods (Ph.D. Thesis)
...Show More Authors

In this study, four different spectrophotometric methods were applied for determination of cimetidine and erythromycin ethylsuccinate drugs in pure form and in their pharmaceutical preparations. The suggested methods are simple, sensitive, accurate, not time consuming and inexpensive. The results showed the following: The first method: Based on the formation of ion pair complex of each drug with bromothymol blue (BTB) as a chromogenic reagent. The formed complexes were extracted with chloroform and their absorbance values were measured at 427.5 nm for cimetidine and 416.5nm for erythromycin ethylsuccinate; against their reagents blanks. Two different methods, univariate method and multivariate method, were used to obtain the optimum condit

... Show More
Preview PDF
Publication Date
Wed Oct 08 2008
Journal Name
Journal Of Kerbala University
Viscosity and Volumetric studies of some amino acids in solutions at different temperatures.
...Show More Authors

Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
THERMAL BUCKLING OF RECTANGULAR PLATES WITH DIFFERENT TEMPERATURE DISTRIBUTION USING STRAIN ENERGY METHOD
...Show More Authors

By using governing differential equation and the Rayleigh-Ritz method of minimizing the total potential energy of a thermoelastic structural system of isotropic thermoelastic thin plates, thermal buckling equations were established for rectangular plate with different fixing edge conditions and with different aspect ratio. The strain energy stored in a plate element due to bending, mid-plane thermal force and thermal bending was obtained. Three types of thermal distribution have been considered these are: uniform temperature, linear distribution and non-linear thermal distribution across thickness. It is observed that the buckling strength enhanced considerably by additional clamping of edges. Also, the thermal buckling temperatures and

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Apr 23 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Antimicrobial susceptibility of Enterococcus spp. Isolated from different clinical sources in Kirkuk provency
...Show More Authors

        One of the most important problems confronts hospitals is the strains emergence  of Enterococcus spp. with multiple resistance to antibiotics, which propel researchers to modify or produce new antibiotics or combination between two antibiotics so that to be more effective against Enterococcus . This study was aimed to susceptibility some of local Enterococcus spp. Isolates with of 21 antibiotic using  disc diffusion method. The results showed absolute resistant 100% toward (Cephalexin , Gentamycin , Amikacin ,Erythromycin and Nalidixic acid), while showed a high sensitivity toward (Vancomycin and Impenem ) at percentage of 92.3% for each . Also highl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
...Show More Authors

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns f

... Show More
View Publication Preview PDF