Preferred Language
Articles
/
rhc2WZABVTCNdQwCsIeN
How geometric reverse engineering techniques can conserve our heritage; a case study in Iraq using 3D laser scanning
...Show More Authors
Abstract<p>Laser scanning has become a popular technique for the acquisition of digital models in the field of cultural heritage conservation and restoration nowadays. Many archaeological sites were lost, damaged, or faded, rather than being passed on to future generations due to many natural or human risks. It is still a challenge to accurately produce the digital and physical model of the missing regions or parts of our cultural heritage objects and restore damaged artefacts. The typical manual restoration can become a tedious and error-prone process; also can cause secondary damage to the relics. Therefore, in this paper, the automatic digital application process of 3D laser modelling of artefacts in virtual restoration is presented based on reverse engineering techniques. Two case studies were selected and processed in Iraq to meet the aim of this research and show how reverse engineering approaches can save our culture. The efficiency and safety of the preservation and restoration of cultural relics are improved and visually demonstrated. Different reverse engineering techniques applied to show the geometric potential for such approaches following laser-based 3D data application.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Electrical and morphological study of thermally evaporated (Sb2S3)1-xSnx thin films
...Show More Authors

(Sb2S3)1-xSnx thin films with different concentrations (0, 0.05 and
0.15) and thicknesses (300,500 and 700nm) have been deposited by
single source vacuum thermal evaporation onto glass substrates at
ambient temperature to study the effect of tin content, thickness and
on its structural morphology, and electrical properties. AFM study
revealed that microstructure parameters such as crystallite size, and
roughness found to depend upon deposition conditions. The DC
conductivity of the vacuum evaporated (Sb2S3)1-x Snx thin films was
measured in the temperature range (293-473)K and was found to
increase on order of magnitude with

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Study of Some Structural Properties of Porous Silicon Preparing by Photochemical Etching
...Show More Authors

Porous Silicon (PSi) has been produced in this work by using Photochemical (PC) etching process by using a hydrofluoric acid (HF) solution. The irradiation has been achieved using quartz- tungsten halogen lamp. The influence of various irradiation times on the properties of PSi اmaterial such as layer thickness, etching rate and porosity was investigated in this work too.
The XRD has been studied to determine the crystal structure and the crystalline size of PSi material

View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Preparation and Identification of some new Pyrazolopyrin derivatives and their Polymerizations study
...Show More Authors

Preparation and Identification of some new Pyrazolopyrin derivatives and their Polymerizations study

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Photostability Study of Some Modified Poly(vinyl chloride) Containing Pendant Schiff’s Bases
...Show More Authors

The polymers modified Poly(vinyl chloride) differ in their tendency to photo oxidation comparing with that unmodified. It has been studied Photostability for modified Poly(vinyl chloride) chains using Schiff’s bases derivative of (5-amino-1, 3, 4-thiadiazole-2-thiol) in a manner casting of plastic chips with thickness (40) in a solvent Tetrahydrofuran. It has been determined the effectiveness Photostability of these modified polymers through the photo degradation rate constant for photostabilizer (kd) for the modified Poly (vinyl chloride). Attributed efficiency of these Poly(vinyl chloride) chips in Photostability by replace the atom Cl Poly(vinyl chloride) chains ends more stable than light stabilizer.

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jun 27 2018
Journal Name
Iraqi Journal Of Science
Theoretical Study of Density Distributions and Size Radii of 8B and 17Ne
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Study the Level of Service to Roadways which Leading to Basrah University
...Show More Authors

The building of Basrah University located in a rural area at Gramat Ali, its consist of seven colleges and very high number of students, lecturers ,and employers. Therefore, the intersections which leading to university building suffer congestion at morning peak hour (8-9) A.M and evening peak hour (2-3) P.M. In this study we collected the data in intersections which leading to university building at peak hour at same time, then we had analysis this data by using the highway capacity manual (HCM) and program (HCS). Also, we collected that data in University entries with classification of vehicles according to types and number of passengers at peak hour. Then we studied the number of proposals to riddance the congestion, such as the effe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives
Study of deposited spray quality of spraying agents with different physical properties
...Show More Authors

The spray quality of two spraying agents with different physical properties was investigated under laboratory conditions to find whether the measurement of deposited drops could be affected by spraying those agents. The first spraying agent Moddus, which is a plant growth regulator, has a surface tension of 28 mN m-1 with almost half the value of the second spraying agent Kelpak (58 mN m-1). A mini boom sprayer containing three flat fan nozzles (XR 11003) was used in the test with three traveling speeds (4.74, 5.42 and 8.13 km. h-1). The test was performed to evaluate the quality of spray drops (spray coverage, spray density and stains diameter) after they were deposited on water sensitive papers (WSP). The results showed a higher ability o

... Show More
Publication Date
Mon Jan 01 2018
Journal Name
Aip Conference Proceedings
Theoretical study of electronic transfer current rate at dye-sensitized solar cells
...Show More Authors

View Publication
Scopus (13)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Mar 01 2007
Journal Name
Al-khwarizmi Engineering Journal
An experimental comparative study between polypropylene and laminated lower limb prosthetic socket
...Show More Authors

Most researchers concentrate their studies on the design, stress and pressure distributions of the prosthetic socket. A little attention is considered for the stiffness of the various materials of the prosthetic sockets. Prosthetic laminated sockets in Iraq are costly to be manufactured while polypropylene socket is relatively cheap in comparing with the laminates.

Experimental study is conducted to compare the stiffness of five prosthetic sockets made of different materials. Compression, three point flexural and tensile tests are implemented by the Testometric machine. The laminate sockets give better results in compression than polypropylene. Polypropylene gives good results in bending compared with the laminate sockets. When t

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 03 2016
Journal Name
Iraqi Journal Of Physics
Study the variation of synodic month for the moon through 2000-2100
...Show More Authors

In this research study the synodic month for the moon and theirrelationship with the mean anomaly for the moon orbit and date A.Dand for long periods of time (100 years), we was design a computerprogram that calculates the period of synodic months, and thecoordinates of the moon at the moment of the new moon with highaccuracy. During the 100 year, there are 1236 period of synodicmonths.We found that the when New Moon occurs near perigee (meananomaly = 0°), the length of the synodic month at a minimum.Similarly, when New Moon occurs near apogee (mean anomaly =180°), the length of the synodic month reaches a maximum. Theshortest synodic month on 2053 /1/ 16 and lasted (29.27436) days.The longest synodic month began on 2008 /11/ 27 a

... Show More
View Publication
Crossref