This paper presents a fuzzy logic controller for a two-tank level control system, which is a process with a dead time. The fuzzy controller is a proportional-integral (PI-like) fuzzy controller which is suitable for steady state behavior of the system. Transient behavior of the system was improved without the need for a derivative action by suitable change in the rule base of the controller. Simulation results showed the step response of the two-tank level control system when this controller was used to control this plant and the effect of the dead time on the response of the system.
Autorías: Mustafa Abdulamir Hussain, Ahmed Sebeaatea Almujamay, Riyadh khaleel khammas. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 5, 2022. Artículo de Revista en Dialnet.
The study focuses on Kamez model and the Claus Meyer model of instructional design, which are models that provide the learner with educational experiences to suit the logical information of the learner and the variety of instructional models. Research Objective: The present research aims to identify Limitations of the study. The current research is determined by ((fourth grade preparatory students, the book of the date of the fourth preparatory course)) Chapter II includes Arabic and foreign studies on the model of Kemp and Claus Mayer in the acquisition of concepts and direction towards the material. Chapter III Experimental Design: The researcher adopted an experimental design with two experimental groups and a control group. The resea
... Show MoreIn this paper, a simulation of the electrical performance for Pentacene-based top-contact bottom-gate (TCBG) Organic Field-Effect Transistors (OFET) model with Polymethyl methacrylate (PMMA) and silicon nitride (Si3N4) as gate dielectrics was studied. The effects of gate dielectrics thickness on the device performance were investigated. The thickness of the two gate dielectric materials was in the range of 100-200nm to maintain a large current density and stable performance. MATLAB simulation demonstrated for model simulation results in terms of output and transfer characteristics for drain current and the transconductance. The layer thickness of 200nm may result in gate leakage current points to the requirement of optimizing the t
... Show MoreThis research is carried out to investigate the behavior of self-compacting concrete (SCC) two-way slabs with central square opening under uniformly distributed loads. The experimental part of this research is based on casting and testing six SCC simply supported square slabs having the same dimentions and reinforcement. One of these slabs was cast without opening as a control slab. While, the other five slabs having opening ratios (OR) of 2.78%, 6.25%, 11.11%, 17.36% and 25.00%. From the experimental results it is found that the maximum percentage decrease in cracking and ultimate uniform loads were 31.82% and 12.17% compared to control slab for opening ratios (OR
... Show MoreSome aspects of population dynamics of both corbicula species inhabiting intertidal zone of
shatt al-Arab are described. These informations are explained in accordance with the possible
occurrence of competition between the two related species.
Ammi species belong to the family Umbellifereae that provide a host of bioactive compounds (mainly coumarins and flavonoids) of important biological activities, like prevention and treatment of heart and vascular disease and some types of cancer. Literature survey revealed that there was no study concerning Ammi flavonoids in Iraq. Ammi majus and Ammi visnaga, which are wildly grown in Iraq, were chosen for this study. This study concerned with extraction, identification, isolation, and purification of some biologically important flavonols quercetin and kaempferol from the fruits of Ammi majus and Ammi visnaga. Extraction of these flavonols was carried out using 85% methanol and 90% e
... Show MoreThis paper studied the behaviour of reinforced reactive powder concrete (RPC) two-way slabs under static load. The experimental program included testing three simply supported slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. Tested specimens were of identical properties except their steel fibers volume ratio (0.5 %, 1 %, and 1.5 %). Static test results revealed that, increasing steel fibers volume ratio from 0.5% to 1% and from 1% to 1.5%, led to an increase in: first crack load by (32.2 % and 52.3 %), ultimate load by (36.1 % and 17.0 %), ultimate deflection by (33.6 % and 3.4 %), absorbed energy by (128 % and 20.2 %), and the ultimate strain by (1.1 % and 6.73 %). The stiffness and ductility of the specimens also increased. A